Person:
Arrabal Durán, Raúl

Loading...
Profile Picture
First Name
Raúl
Last Name
Arrabal Durán
Affiliation
Universidad Complutense de Madrid
Faculty / Institute
Ciencias Químicas
Department
Ingeniería Química y de Materiales
Area
Ciencia de los Materiales e Ingeniería Metalúrgica
Identifiers
UCM identifierORCIDScopus Author IDWeb of Science ResearcherIDDialnet ID

Search Results

Now showing 1 - 10 of 19
  • Publication
    Hard Anodizing and Plasma Electrolytic Oxidation of an Additively Manufactured Al-Si alloy
    (Elsevier Science, 2021-05-26) Mora Sánchez, H.; Olmo, Rubén del; Rams, J.; Torres, B.; Mohedano Sánchez, Marta; Matykina, E.; Arrabal Durán, Raúl
    Plasma Electrolytic Oxidation (PEO) and Hard Anodizing (HA) coatings are investigated on an Additively Manufactured (AM) Al10Si1Mg alloy obtained via Direct Metal Laser Sintering (DMLS). Results are compared to those obtained for a conventional A361 cast alloy. Findings revealed that the microstructure of the AM alloy, consisting of α-Al cells enclosed in a Si network, produces coatings that are more uniform –in terms of morphology, thickness and roughness of the coating/substrate interface– than those obtained on the cast alloy. However, enhanced oxidation of the fine Si network in the AM alloy results in softer coatings. In both alloys, PEO coatings demonstrate superior wear protection than HA due to the presence of mullite in the former. The anisotropy in the microstructure of the AM alloy influences the tribological behaviour of studied coatings, with the XZ plane showing superior wear performance.
  • Publication
    Effect of cerium (IV) on thin sulfuric acid anodizing of 2024-T3 alloy
    (Elsevier Science BV, 2021-10-07) Olmo, R. del; Mohedano Sánchez, Marta; Visser, P.; Rodríguez Rodríguez, Araceli; Matykina, E.; Arrabal Durán, Raúl
    Chromic acid anodizing (CAA) is still being used today for corrosion protection of fatigue-critical components in the aeronautic industry due to the lack of feasible alternatives. Ce-containing sulfuric acid anodizing (SAA) has been identified as a promising strategy for the development of alternatives to toxic CAA. This work explores thin sulfuric acid anodizing (TSAA) focusing on the following effects: (i) current density and voltage values; (ii) concentration of Ce(IV). Screening of the optimum combination in search of minimum thickness and the best corrosion resistance was performed using electrochemical impedance spectroscopy (EIS). Two Ce-containing anodic films were selected and further investigated in comparison with the inhibitor-free film in terms of morphology (FEG-SEM, TEM), composition (RBS), corrosion resistance (EIS, NSST), high-cycle fatigue and paint adhesion. The results indicate that the path to approach the CAA performance lies through thin (<1 μm) SAA-Ce films formed at low current density.
  • Publication
    Design and Multidimensional Screening of Flash-PEO Coatings for Mg in Comparison to Commercial Chromium(VI) Conversion Coating
    (MDPI, 2021-02-17) Wierzbicka, Ewa; Mohedano Sánchez, Marta; Matykina, Endzhe; Arrabal Durán, Raúl
    REACH (Registration, Evaluation, Authorisation and Restriction of Chemicals) regulations demand for an expedient discovery of a Cr(VI)-free alternative corrosion protection for light alloys even though the green alternatives might never be as cheap as current harmful technologies. In the present work, flash- plasma electrolytic oxidation coatings (FPEO) with the process duration < 90 s are developed on AZ31B alloy in varied mixtures of silicate-, phosphate-, aluminate-, and fluoride-based alkaline electrolytes implementing current density and voltage limits. The overall evaluation of the coatings’ anticorrosion performance (electrochemical impedance spectroscopy (EIS), neutral salt spray test (NSST), paintability) shows that from nine optimized FPEO recipes, two (based on phosphate, fluoride, and aluminate or silicate mixtures) are found to be an adequate substitute for commercially used Cr(VI)-based conversion coating (CCC). The FPEO coatings with the best corrosion resistance consume a very low amount of energy (~1 kW h m−2 µm−1). It is also found that the lower the energy consumption of the FPEO process, the better the corrosion resistance of the resultant coating. The superb corrosion protection and a solid environmentally friendly outlook of PEO-based corrosion protection technology may facilitate the economic justification for industrial end-users of the current-consuming process as a replacement of the electroless CCC process.
  • Publication
    Calcium Doped Flash-PEO Coatings for Corrosion Protection of Mg Alloy
    (MDPI, 2020-07-09) Wierzbicka, Ewa; Pillado Rios, Borja; Mohedano Sánchez, Marta; Arrabal Durán, Raúl; Matykina, Endzhe
    This study demonstrates a significant improvement of the corrosion resistance of an AZ31B magnesium alloy achieved by the application of 1 um-thin coatings generated by an environmentally friendly flash plasma electrolytic oxidation (FPEO) process in Ca-containing electrolytes. Two compounds with different solubility, calcium oxide (CaO) or calcium glycerophosphate (CaGlyP), were used as sources of Ca in the electrolyte. Very short durations (20–45 s) of the FPEO process were employed with the aim of limiting the energy consumption. The corrosion performance of the developed coatings was compared with that of a commercial conversion coating (CC) of similar thickness. The viability of the coatings in a full system protection approach, consisting of FPEO combined with an inhibitor-free epoxy primer, was verified in neutral salt spray and paint adhesion tests. The superior corrosion performance of the FPEO_CaGlyP coating, both as a stand-alone coating and as a full system, was attributed to the formation of a greater complexity of Ca2+ bonds with SiO2 and PO4 3- species within the MgO ceramic network during the in situ incorporation of Ca into the coating from a double chelated electrolyte and the resultant difficulties with the hydrolysis of such a network. The deterioration of the FPEO_CaGlyP coating during immersion was found over ten times slower compared with Ca-free flash-PEO coating.
  • Publication
    Energy consumption, wear and corrosion of PEO coatings on preanodized Al alloy: the influence of current and frequency
    (MPDI, 2022-10-13) Mohedano Sánchez, Marta; López, E.; Mingo Román, Beatriz; Moon, S.; Matykina, Endzhe; Arrabal Durán, Raúl
    The influence of current and frequency on energy consumption of plasma electrolytic oxidation (PEO) of a commercial aluminium alloy pre-treated by conventional anodizing in sulphuric acid has been investigated. The combination of a 20-μm thick precursor anodic porous film, high current (500 mA cm−2) and frequency (400 Hz) during PEO enables up to 76% energy savings compared to direct PEO treatment (50 Hz). The time needed to achieve a uniform coating thickness was also reduced from 3350 s to 750 s, for PEO_50 and A + PEO_400, respectively. The wear and corrosion performance of the optimised coatings (400 Hz) were also improved despite the lower thickness of the coatings. Such improvement was mainly attributed to the microstructural refinement associated with high frequency processing and early transaction to the “soft-sparking” regime. The modification of the frequency has a stronger influence on the corrosion response than the presence of the anodic precursor. The best corrosion response was obtained for PEO_400 followed closely by A + PEO_400.
  • Publication
    Combination of Electron Beam Surface Structuring and Plasma Electrolytic Oxidation for Advanced Surface Modification of Ti6Al4V Alloy
    (MDPI, 2022) Mora-Sanchez, Hugo; Pixner, Florian; Buzolin, Ricardo; Mohedano Sánchez, Marta; Arrabal Durán, Raúl; Warchomicka, Fernando; Matykina, Endzhe
    The objective of this work is to study for the first time the combination of electron beam (EB) surface structuring and plasma electrolytic oxidation (PEO) with the aim of providing a multiscale topography and bioactive surface to the Ti6Al4V alloy for biomedical applications. Ca and P-containing coatings were produced via 45 s PEO treatments over multi-scale EB surface topographies. The coatings morphology and composition were characterized by a means of scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). The effect on the previous EB topography was evaluated by means of a 3D optical profilometry and electrochemical response via potentiodynamic polarization tests. In general, the PEO process, morphology, composition and growth rate of the coatings were almost identical, irrespective of the topography treated. Minimal local differences were found in terms of morphology, and the growth rate were related to specific topographical features. Nevertheless, all the PEO-coated substrates presented essentially the same corrosion resistance. Electrochemical tests revealed a localized crevice corrosion susceptibility of all the bare EB topographies, which was successfully prevented after the PEO treatment.
  • Publication
    Flash-PEO coatings loaded with corrosion inhibitors on AA2024
    (Elsevier, 2020-08-20) Olmo Martínez, Rubén del; Mohedano Sánchez, Marta; Visser, Peter; Matykina, Endzhe; Arrabal Durán, Raúl
    Flash plasma electrolytic oxidation (flash-PEO) with in situ incorporation of inhibitors is explored as a strategy for corrosion protection of 2024 aluminium (Al) alloys. Thin (~5 μm) and energy-efficient coatings were successfully developed on the Al substrate in 100 s treatment time using different electrolytes based on molybdate, stannate, tungstate, vanadate lanthanum or cerium salts additives with and without complexing agent (EDTA). Screening of the optimum combination in search of minimum thickness and best corrosion protective performance was performed using electrochemical impedance spectroscopy (EIS). Coatings based on EDTA-Ce and WO42 were selected and investigated further in comparison with the inhibitor-free phosphate coating in terms of morphology, composition, corrosion behaviour and paint adhesion. EDTA-Ce coating showed excellent paint adhesion and the highest impedance modulus at short immersion times in 3.5 wt% NaCl aqueous solution. Neutral salt spray testing of this coating as a full system comprising an epoxy primer showed no signs of corrosion after 1000 h of exposure.
  • Publication
    Layered Double Hydroxide Coatings Loaded with Corrosion Inhibitors for Corrosion Protection of AZ31 †
    (MDPI, 2021) Pillado Rios, Borja; Mohedano Sánchez, Marta; Olmo Martínez, Rubén del; Mingo, Beatriz; Matykina, Endzhe; Arrabal Durán, Raúl
    Layered double hydroxide (LDHs) coatings were developed for the corrosion protection of AZ31 Mg alloy. AZ31 is widely used in the transport industry due to its low mass density and good mechanical properties. LDH coatings were fabricated under co-precipitation conditions and applied under hydrothermal conditions. Two different systems Zn-Al LDH and Li-Al LDH were studied. Specimens were post-treated via immersion for 2 h at 45 °C in inhibitor aqueous baths. Na2WO4·H2O and LiNO3 inorganic inhibitors were used, respectively, to produce inhibitor-loaded systems: Zn-Al LDH(W) and Li-Al LDH(Li). The characterization of the coatings was carried out by field-emission scanning electron microscope (FESEM), X-ray diffraction (XRD) and Fourier transform infrared spectroscopy (FTIR). The corrosion process was studied by electrochemical impedance spectroscopy (EIS) and scanning vibrating electrode technique (SVET). The surface was also evaluated via the determination of water drop contact angle and the performance of a paint adhesion test using an epoxy primer. The characterization of the coating revealed two-layered coatings with a denser inner layer and a flaky outer layer. Both coatings improved the corrosion resistance of the AZ31 alloy. Loading with inhibitor further increased the corrosion resistance by one order of magnitude (bare substrate, Z10mHz~102 Ω cm2; LDH, Z10mHz~103–4 Ω cm2; LDH-inhibitor, Z10mHz~105 Ω cm2).
  • Publication
    PLA deposition on surface treated magnesium alloy: Adhesion, toughness and corrosion behaviour
    (Elsevier Science, 2020-04-25) Muñoz, Marta; Torres, Belén; Mohedano Sánchez, Marta; Matykina, Endzhe; Arrabal Durán, Raúl; López, A.J.; Rams, J.
    This study shows that the use of polylactic acid polymer (PLA) coatings deposited by dip-coating on AZ31 magnesium alloy can increase the integrity of the system and the fracture toughness of magnesium substrates treated by plasma electrolytic oxidation (PEO). This provides a novel and promising use of a multilayered system made of fully biocompatible materials. The maximum adhesion strength value for PLA coatings on AZ31 was >50% higher than the maximum one for AZ31/PEO/PLA, while the maximum bending strain tripled. The limitations observed in the AZ31/PEO system arise from the brittle nature of the oxides formed during PEO treatments; their negative impact is reduced when incorporating a PLA layer that is capable of filling the pores and sealing the cracks of the PEO layer. PLA coatings reduce corrosion of AZ31 and maintain the corrosion protection provided by the PEO treatments. The characteristics of the PLA coatings on AZ31 Mg alloy and on AZ31/PEO systems were evaluated by using a Taguchi design of experiment (DOE) method using the following processing parameters: (i) number of layers, (ii) withdrawal speed and (iii) polymer concentration. The effect of these three degrees of freedom and, the surface treatment has been evaluated with regards to different properties desired for the coatings, i.e., adhesion, thickness, roughness, and corrosion resistance.
  • Publication
    Biotribology and biocorrosion of MWCNTs-reinforced PEO coating on AZ31B Mg alloy
    (Elsevier Science, 2021-03-05) Daavari, Morteza; Atapour, Masoud; Mohedano Sánchez, Marta; Arrabal Durán, Raúl; Matykina, Endzhe; Taherizadeh, Aboozar
    Over the last two decades, various methods have been developed for surface modification of Mg alloys among which plasma electrolytic oxidation (PEO) is one of the most effective methods for tailoring surface properties. However, PEO coatings still need to be improved in various aspects, including mechanical and corrosion performances. In the current study, multi-walled carbon nanotubes (MWCNTs) were incorporated into a PEO coating structure via one-step process. Characterization techniques in this study included scanning electron microscopy (SEM), Raman spectroscopy and X-ray diffraction (XRD). Corrosion behavior was evaluated by electrochemical tests taking into account quasi-in vivo conditions in order to get closer to implant degradation rates in human body. Dry-wear and tribocorrosion in SBF were also evaluated in reciprocal ball-on-plate mode. According to the findings, MWCNTs induced several microstructural modifications in PEO coating such as formation of ~ 1 μm homogeneous dense barrier layer and irregular-shape porosities. Reinforcement significantly improved pitting corrosion resistance of the PEO coating, yielded a low friction coefficient and decreased wear-related damage by 60%.