Person:
Carracedo Rodríguez, Juan Gonzalo

Loading...
Profile Picture
First Name
Juan Gonzalo
Last Name
Carracedo Rodríguez
Affiliation
Universidad Complutense de Madrid
Faculty / Institute
Óptica y Optometría
Department
Optometría y Visión
Area
Optica
Identifiers
UCM identifierORCIDScopus Author IDDialnet IDGoogle Scholar ID

Search Results

Now showing 1 - 8 of 8
  • Publication
    Signs and Symptoms of Dry Eye in Keratoconus Patients Before and After Intrastromal Corneal Rings Surgery
    (Taylor & Francis, 2017) Carracedo Rodríguez, Juan Gonzalo; Recchioni, Alberto; Alejandre Alba, Nicolás; Martín Gil, Alba; Batres Valderas, Laura; Jiménez Alfaro-Morote, Ignacio; Pintor, Jesús
    Purpose: Based on the relationship between keratoconus and dry eye, the aim of this study was to evaluate changes in signs and symptoms of dry eye in keratoconus patients before and after intrastromal corneal ring surgery. Methods: Fifteen keratoconus patients were enrolled in Fundación Jiménez-Díaz of Madrid and University Clinic of Optometry of the Universidad Complutense de Madrid (Madrid, Spain). Tear break up time (TBUT), Schirmer test without anesthesia, corneal staining, diadenosine tetraphosphate (Ap4A) concentration, and ocular surface disease index (OSDI) were evaluated. Impression cytology combined with laser confocal microscopy was performed to evaluate goblet cell density, mucin cloud height (MCH), and cell layer thickness (CLT). All measurements were performed before (pre) surgery, 1 month (post) and 6 months after surgery (post6m). Results: We found no statistical differences in time in Schirmer test, TBUT, and corneal staining. OSDI scores were 44.96  ±  8.65, 26.30 ± 6.79, and 19.31 ± 4.28 for (pre), (post), and (post6m) surgery, respectively (p < 0.001). Impression cytology showed a decrease in cell density at (post6m) compared with presurgery (47.36 ± 35.15 cells/mm2 and 84.88 ± 32.08 cells/mm2, respectively, p = 0.04). At post6m, the MCH increased compared with presurgery values (13.97 ± 4.26 µm and 6.77 ± 2.51 µm, respectively, p < 0.001). There was a statistically significant increase in CLT in time. Ap4A tear concentrations were lower post6m than presurgery (1.02  ±  0.65 and 2.56   ± 1.10  µM, respectively, p < 0.001). Conclusion: Intrastromal corneal ring surgery induces changes improving dry eye symptoms but no changes were found in signs of dry eye after surgery in keratoconus patients except for the MCH that increases drastically. More studies are needed to clarify the reason of its improvement.
  • Publication
    Comparison of Intraocular Pressure before and after Laser In Situ Keratomileusis Refractive Surgery Measured with Perkins Tonometry, Noncontact Tonometry, and Transpalpebral Tonometry
    (Hindawi Publishing Corporation, 2015) Cacho, Isabel; Sánchez Naves, Juan; Batres Valderas, Laura; Carracedo Rodríguez, Juan Gonzalo; Pintor Just, Jesús
    Purpose. To compare the intraocular pressure (IOP) before and after Laser In Situ Keratomileusis (LASIK), measured by Diaton, Perkins, and noncontact air pulse tonometers. Methods. Fifty-seven patients with a mean age of 34.88 were scheduled for myopia LASIK treatment. Spherical equivalent refraction (SER), corneal curvature (K), and central corneal thickness (CCT) and superior corneal thickness (SCT) were obtained before and after LASIK surgery. IOP values before and after surgery were measured using Diaton, Perkins, and noncontact air pulse tonometers. Results. The IOP values before and after LASIK surgery using Perkins tonometer and air tonometers were statistically significant (). However, no significant differences were found () for IOP values measured with Diaton tonometer. CCT decreases significantly after surgery () but no statistical differences were found in SCT (). Correlations between pre- and postsurgery were found for all tonometers used, with and for the air pulse tonometer, and for Perkins, and and for Diaton. Conclusion. Transpalpebral tonometry may be useful for measuring postsurgery IOP after myopic LASIK ablation because this technique is not influenced by the treatment.
  • Publication
    Comparison Between Viscous Teardrops and Saline Solution to Fill Orthokeratology Contact Lenses Before Overnight Wear
    (Contact Lens Association of Ophthalmologists, Inc, 2018-09) Carracedo Rodríguez, Juan Gonzalo; Villa Collar, César; Martín Gil, Alba; Serramito Blanco, María; Santamaría, Leticia
    Objective: To compare, in terms of efficacy, the differences between the use of saline solution and a viscous artificial tear to fill the lens during the first month of orthokeratology wear. Methods: A pilot, double-masked, crossed, randomized, and prospective study was conducted. In this study, 20 subjects (14 males and 6 females) with a mean age of 16.29±6.22 years (range, 10–26) were fitted with orthokeratology contact lenses. For the study, nonpreserved 0.9% NaCl commercial saline solution (Avizor, Madrid, Spain) and nonpreserved artificial teardrops with 0.3% of hyaluronic acid (Ocudry 0.3%; Avizor, Madrid, Spain) were used. Corneal staining, tear break up time (TBUT), topography, refraction, visual acuity, and subjective comfort and vision with the visual analog scale (score from 0 to 10, being 10 better comfort and vision) were evaluated at 1 day, 1 week, and 1 month of contact lens wear. Results: The corneal staining was statistically greater in the saline group than in the Ocudry group for the first day and during 1 week of wear (P<0.05). Comfort was found to be statistically better, with Ocudry 0.3% than saline solution, being 7.17±1.94 and 6.37±1.63, for the first day, and 8.78±0.43 and 8.15±0.62 for the day 28, respectively (P<0.05). However, no differences were found for subjective vision scores, TBUT, spherical equivalent, best-corrected visual acuity and uncorrected visual acuity, and mean keratometry between groups for any visit (P>0.05). Conclusion: Viscous artificial tears improve the subjective comfort of patients and reduce the corneal staining, compared with saline solution during the orthokeratology lenses fitting process. However, no differences between solutions for the treatment efficacy, in vision and corneal topography, were found.
  • Publication
    The Topographical Effect of Optical Zone Diameter in Orthokeratology Contact Lenses in High Myopes
    (Hindawi, 2019-01-02) Carracedo Rodríguez, Juan Gonzalo; Espinosa Vidal, Teresa M.; Martínez Alberquilla, Irene; Batres Valderas, Laura
    Purpose. To evaluate the effect of the optical zone diameter (OZ) in orthokeratology contact lenses regarding the topographical profile in patients with high myopia (−4.00 D to −7.00 D) and to study its effect over the visual quality. Materials and Methods. Twelve patients (18 eyes) were fitted with overnight orthokeratology (OrthoK) with a randomized 6 mm or 5 mm OZ lens worn for 2 weeks, followed by a 2-week washout period, between both designs. Keratometry (K) readings, optical zone treatment diameter (OZT), peripheral ring width (PRW), higher-order aberrations (HOA), high (HC) and low contrast (LC) visual acuity, and subjective vision and comfort were measured at baseline and after 2 weeks of OrthoK lens wear of each contact lens. Results. No significant differences were found between any measurements for the same subject at both baselines ( value > 0.05). There was no difference between OZ lens designs found in refraction, subjective vision or comfort, and HC and LC visual acuity. Contrast sensitivity was decreased in the 5 mm OZ lens design compared with 6 mm OZ design (-value < 0.05). 5 mm OZ design provoked a greater flattening, more powerful midperipheral ring and 4th-order corneal and total spherical aberration than the 6 mm OZ design, being statistically significant after 7 days, for corneal aberration, and 15 days, for corneal and total, of wearing the lens (-value < 0.05). The OZT obtained were 2.8 ± 0.2 mm and 3.1 ± 0.1 mm for 5 mm and 6 mm OZ design, respectively (-value < 0.05). Regarding PRW, the 5 mm OZ design had a wider ring width in both the nasal and temporal zones (-value < 0.05). Conclusions. A smaller diameter optical zone (5 mm) in orthokeratology lenses produces a smaller treatment area and a larger and more powerful midperipheral ring, increasing the 4th-order spherical aberration that affects only the contrast sensitivity but without differences in visual acuity and subjective vision compared with a larger OZ diameter (6 mm).
  • Publication
    Changes in Peripheral Refractive Profile after Orthokeratology for Different Degrees of Myopia
    (Taylor & Francis, 2016) González-Méijome, José Manuel; Faria Ribeiro, Migue A.; Lopes Ferreira, Daniela P.; Fernandes, Paulo; Carracedo Rodríguez, Juan Gonzalo; Queiros, Antonio
    Purpose: The purpose of this study was to evaluate the effect of orthokeratology for different degrees of myopia correction in the relative location of tangential (FT) and sagittal (FS) power errors across the central 70° of the visual field in the horizontal meridian. Methods: Thirty-four right eyes of 34 patients with a mean age of 25.2 ± 6.4 years were fitted with Paragon CRT (Mesa, AZ) rigid gas permeable contact lenses to treat myopia (−2.15 ± 1.26D, range: −0.88 to −5.25D). Axial and peripheral refraction were measured along the central 70° of the horizontal visual field with the Grand Seiko WAM5500 open-field auto-refractor. Spherical equivalent (M), as well as tangential (FT) and sagittal power errors (FS) were obtained. Analysis was stratified in three groups according to baseline spherical equivalent: Group 1 [MBaseline = −0.88 to −1.50D; n = 11], Group 2 [MBaseline = −1.51 to −2.49D; n = 11], and Group 3 [MBaseline = −2.50 to −5.25D; n = 12]. Results: Spherical equivalent was significantly more myopic after treatment beyond the central 40° of the visual field (p < 0.001). FT became significantly more myopic for all groups in the nasal and temporal retina with 25° (p ≤ 0.017), 30° (p ≤ 0.007) and 35° (p ≤ 0.004) of eye rotation. Myopic change in FS was less consistent, achieving only statistical significance for all groups at 35° in the nasal and temporal retina (p ≤ 0.045). Conclusions: Orthokeratology changes significantly FT in the myopic direction beyond the central 40° of the visual field for all degrees of myopia. Changes induced by orthokeratology in relative peripheral M, FT and FS with 35° of eye rotation were significantly correlated with axial myopia at baseline.
  • Publication
    Stabilization in early adult-onset myopia with corneal refractive therapy
    (Elsevier, 2016-02) González Méijome, José Manuel; Carracedo Rodríguez, Juan Gonzalo; Lopes Ferreira, Daniela P.; Faria Ribeiro, Migue A.; Peixoto de Matos, Sofía C.; Queiros, Antonio
    Purpose: To describe the stabilization of early adult-onset myopia in three university students after initiating orthokeratology treatment with corneal refractive therapy contact lenses. Methods: Three Caucasian early adult-onset progressing myopic subjects (1 male, 2 females) were fitted with corneal refractive therapy lenses to correct myopia between −1.50 and −2.50 D of sphere using Paragon CRT (Paragon Vision Sciences, Mesa, AZ) lenses for overnight orthokeratology. The pre-treatment refractive history from 2005 as well as refraction and axial length after treatment onset are reported over a period of 3 years between December 2009 and January 2013 with an additional year of follow-up after treatment discontinuation (January–December 2013). The peripheral refractive patterns and topographic changes are also reported individually. Results: Treatment was successful in all three subjects achieving uncorrected visual acuity of 20/20 or better monocularly. During a period of 3 years of follow-up the subjects did not experience progression in their refractive error, nor in their axial length (measured during the last 2 years of treatment and 1 year after discontinuation). Furthermore, the subjects recovered to their baseline refraction and did not progressed further over the following year after lens wear discontinuation. Conclusions: We cannot attribute a causative effect to the orthokeratology treatment alone as underlying mechanism for myopia stabilization in this 3 patients. However, the present report points to the possibility of stabilization of early adult-onset myopia progression in young adults using corneal refractive therapy treatment.
  • Publication
    Effect of overnight orthokeratology on conjunctival goblet cells
    (Elsevier, 2016-08) Carracedo Rodríguez, Juan Gonzalo; Martín Gil, Ana; Fonseca, Begoña; Pintor, Jesús
    Objective: To evaluate the differences between goblet cell density (GCD) and symptomatology after one month of orthokeratology lens wear. Methods: A pilot, short-term study was conducted. Twenty-two subjects (29.7. ±. 7.0 years old) participated voluntarily in the study. Subjects were divided into two groups: habitual silicone hydrogel contact lens wearers (SiHCLW) and new contact lens wearers (NCLW). Schirmer test, tear break up time (TBUT), Ocular Surface Disease Index (OSDI) questionnaire and conjunctival impression cytology. GCD, mucin cloud height (MCH) and cell layer thickness (CLT) were measured. All measurements were performed before orthokeratology fitting and one month after fitting to assess the evolution of the changes throughout this time. Results: No differences in tear volume and TBUT between groups were found (p>0.05). However, the OSDI score was statistically better after one month of orthokeratology lens wear than the baseline for the SiHCLW group (p=0.03). Regarding the goblet cell analysis, no differences were found in CLT and MCH from the baseline visit to the one month visit for the SiHCLW compared with NCLW groups (p>0.05). At baseline, the GCD in the SiHCLW group were statistically lower than NCLW group (p<0.001). There was a significant increase in GCD after orthokeratology fitting from 121±140cell/mm2 to 254±130cell/mm2 (p<0.001) in the SiHCLW group. Conclusion: Orthokeratology improves the dry eye subject symptoms and GCD after one month of wearing in SiHCLW. These results suggest that orthokeratology could be considered a good alternative for silicone hydrogel contact lens discomfort and dryness. © 2016 British Contact Lens Association.
  • Publication
    The effect of soft contact lens thickness in visual function after intracorneal ring segments surgery
    (Elsevier, 2017-10-06) Carracedo Rodríguez, Juan Gonzalo; Canales Calvo, Javier; González Balboa, Paula; Recchioni, Alberto; Carpena Torres, Carlos; Carballo Álvarez, Jesús
    Objective: To study the influence of soft contact lens (SCL) central thickness and material in keratoconus on visual function after intracorneal ring segment (ICRS) surgery. Methods: A pilot, experimental, prospective, cross-sectional and double-blind study was performed. Fourteen keratoconus patients with age range of 34.75 ± 9.22 years (7 males and 7 females) with ICRS implanted were involved in the study. Two different SCL materials [Hioxifilcon A (G-5X/p-GMA/HEMA) and Lucifilcon A (silicone-hydrogel)] with four different central thicknesses (0.1, 0.2, 0.3 and 0.4 mm) were fitted in one eye per patient, selected randomly. High and low corrected distance visual acuity (CDVA) and contrast sensitivity (CS), corneal topography and corneal and total aberrometry were measured. Results: Corneal spherical like, coma like and root mean square (RMS) decreased significantly for 0.3 and 0.4 mm in both SCL materials (p < 0.05). Total RMS decreased significantly for 0.4 mm with both SCL materials (p < 0.05). High and low CDVA improved for 0.4 mm of thickness for both materials (p < 0.05). Statistically increasing were found in all thicknesses studied for CS in both materials (p < 0.05). Conclusion: A central thickness of the SCL equal or superior to 0.4 mm seems to decrease the ocular high order aberration (HOA) and to improve the visual function in keratoconus patients implanted with ICRS. However, the modulus of rigidity of the SCL would not influence the HOA correction.