TY - JOUR AU - Barragán García, Vicenta María AU - Ruiz Bauzá, Carlos AU - Imaña Pascual, José Luis PY - 2002 DO - 10.1016/S0011-9164(02)00205-9 SN - 0011-9164 UR - https://hdl.handle.net/20.500.14352/58418 T2 - Desalination AB - The influence of an alternating (AC) sinusoidal perturbation, of known frequency and small amplitude, superimposed to the usual applied continuous (DC) signal in a desalination electrodialysis process has been studied. The experiments were carried out... LA - eng M2 - 235 PB - Elsevier Science Bv KW - Cation-Exchange Membrane KW - Electroosmosis KW - Recovery KW - Acids. TI - Effect of an AC perturbation on a desalination electrodialysis process TY - journal article VL - 142 ER -