RT Journal Article T1 Intrastromal corneal ring segment implantation for high astigmatism after penetrating keratoplasty A1 Arriola Villalobos, Pedro A1 Díaz Valle, David A1 Güell, José Luis A1 Iradier Urrutia, María Teresa A1 Jiménez Alfaro, Iñigo A1 Cuiña Sardiña, Ricardo A1 Benítez Del Castillo Sánchez, José Manuel AB Purpose: To evaluate the safety and efficacy of intracorneal ring segments (ICRS) for high astigmatism after penetrating keratoplasty (PKP). Setting: Department of Ocular Surface and Inflammation, Ophthalmology, Hospital Clínico San Carlos, Complutense University, Madrid, Spain. Methods: This retrospective noncomparative study comprised eyes with high post-PKP astigmatism (>4.00 diopters [D]), contact lens intolerance, and a minimum follow-up of 24 months who had ICRS (Kerarings) implantation by mechanical stromal dissection. Corrected distance visual acuity (CDVA), refractive astigmatism, spherical equivalent (SE), surgically induced astigmatism (SIA), central corneal curvature, topographic corneal astigmatism, average corneal power, and complications were assessed. Results: The mean CDVA was statistically significantly better postoperatively (0.23 ± 0.21) than preoperatively (0.98 ± 0.27) (P = .007); no eye lost CDVA. The mean refractive astigmatism decreased from 6.17 ± 1.12 D to 4.04 ± 1.67 D (P = .068) and the mean SE from -3.17 ± 5.48 D to -0.12 ± 2.40 D (P = .34). The mean SIA was 4.55 ± 2.83 D. The mean central corneal curvature decreased from 46.28 ± 1.73 D to 42.09 ± 3.20 D (P<.01); the mean topographic corneal astigmatism, from 7.07 ± 2.52 D to 4.48 ± 2.00 D (P<.05) and the mean average corneal power from 45.92 ± 1.59 D to 41.88 ± 3.37 D (P<.01); all decreases were statistically significant. One patient developed deep vascularization in the lower temporal stromal channel that resolved after ICRS removal. One patient reported significant night halos. Conclusion: Implantation of ICRS for high post-PKP astigmatism reduced corneal curvature and topographic astigmatism, significantly improving CDVA PB Wolters Kluwer SN 0886-3350 YR 2009 FD 2009-11-15 LK https://hdl.handle.net/20.500.14352/112578 UL https://hdl.handle.net/20.500.14352/112578 LA eng NO Arriola-Villalobos, Pedro MD∗; Díaz-Valle, David MD, PhD; Güell, Jose Luis MD, PhD; Iradier-Urrutia, María Teresa MD, PhD; Jiménez-Alfaro, Iñigo MD, PhD; Cuiña-Sardiña, Ricardo MD; Benítez-del-Castillo, José Manuel MD, PhD. Intrastromal corneal ring segment implantation for high astigmatism after penetrating keratoplasty. Journal of Cataract & Refractive Surgery 35(11):p 1878-1884, November 2009. | DOI: 10.1016/j.jcrs.2009.05.060 DS Docta Complutense RD 15 dic 2025