TY - JOUR AU - Campelo-Parada, Francisco et al. AU - Nombela-Franco, Luis AU - Rodés-Cabau, Josep AU - Pérez Castellano, Nicasio AU - Macaya Miguel, Carlos PY - 2018 DO - 10.1016/j.recesp.2017.03.032 SN - 1885-5857 UR - https://hdl.handle.net/20.500.14352/100552 T2 - Rev. ESPAÑOLA DE CARDIOLOGÍA AB - Introduction and objectives: Little is known about the timing of onset and outcome of conduction abnormalities (CA) following balloon-expandable transcatheter aortic valve implantation. The aim of this study was to examine the timing of CA and... LA - eng M2 - 162 PB - Sociedad española de cardiología KW - Alteraciones de la conducción KW - Aortic stenosis KW - Balloon aortic valvuloplasty KW - Bloqueo de rama izquierda KW - Conduction abnormalities KW - Conduction disturbances KW - Direct transcatheter aortic valve implantation KW - Estenosis aórtica KW - Implante percutáneo de válvula aórtica KW - Implante percutáneo de válvula aórtica directo KW - Left bundle branch block KW - Marcapasos KW - Pacemaker KW - Transcatheter aortic valve implantation KW - Trastornos de la conducción KW - Valvuloplastia aórtica con balón TI - Timing of Onset and Outcome of New Conduction Abnormalities Following Transcatheter Aortic Valve Implantation: Role of Balloon Aortic Valvuloplasty TY - journal article VL - 71 ER -