%0 Journal Article %A Viñas Pérez, María %A González Ramos, Ana María %A Aisatti, Sara %A Garzón Jiménez, Nuria %A Poyales Galán, Francisco %A Dorronsoro Díaz, Carlos %A Marcos Celestino, Susana %T Longitudinal Chromatic Aberration in Patients Implanted With Trifocal Diffractive Hydrophobic IOLs %D 2020 %@ 1081-597X %U https://hdl.handle.net/20.500.14352/7634 %X PURPOSE: To measure the in vivo longitudinal chromatic aberration (LCA) from the chromatic difference of focus (480 to 700 nm) using psychophysical methods in patients bilaterally implanted with a hydrophobic trifocal intraocular lens (IOL).METHODS: Psychophysical best focus was measured in both eyes at different wavelengths (480 to 700 nm) and at three different viewing distances (0.00, +1.75, and +3.50 diopters [D]) using a custom-developed polychromatic adaptive optics set-up provided with a supercontinuum laser, a Hartmann-Shack wavefront sensor, a deformable mirror, a motorized Badal system, a pupil monitoring system, and a psychophysical channel with monochromatically illuminated stimuli. Measurements were performed on 10 patients (20 eyes) bilaterally implanted with hydrophobic trifocal diffractive IOLs (FineVisionHP POD F GF; PhysIOL). LCA was computed from the chromatic difference of focus curves as the difference between 480 and 700 nm at near, intermediate, and far.RESULTS:The LCA from psychophysical measurements was significantly higher for far vision (0.99 ± 0.06 diopters [D]), than for intermediate (0.67 ± 0.10 D) and near (0.23 ± 0.08 D) vision (one-way analysis of variance, P < .05).CONCLUSIONS: LCA for far vision was significantly higher than for intermediate and near vision in hydrophobic trifocal diffractive IOLs, in agreement with a previous study with the same optical design but hydrophilic material IOLs. The LCA for the hydro-phobic IOL is slightly higher than for the hydrophilic IOL at far. Different combinations of refractive and diffractive LCA will allow optimizing IOL designs to improve polychromatic image quality. %~