TY - JOUR AU - Ballesteros, Juan AU - Vasquez, Solange AU - Revilla-León, Marta AU - Gómez Polo, Miguel Ángel PY - 2025 DO - 10.1111/cid.70072 SN - 1523-0899 UR - https://hdl.handle.net/20.500.14352/122518 T2 - Clinical Implant Dentistry and Related Research AB - Purpose: The present study aims to evaluate whether differences in accuracy of the implant positions exist for static computer-aided implant placement based on the manufacturing process of surgical guides and the inclusion or not of metal... LA - eng M2 - e70072 PB - Wiley KW - 3D printing KW - Dental implants KW - Metal sleeves KW - Milling KW - Sleeveless KW - Static computer‐aided implant placement TI - A comparative study on the accuracy of implant placement using 3D-printed and milled guides without metal sleeve TY - journal article VL - 27 ER -