RT Journal Article T1 Power profile and optical performance of two extended range of vision intraocular lens designs A1 Vega, Fidel A1 Garzón Jiménez, Nuria A1 García Montero, María A1 Millán, María Sagrario AB Purpose: To assess the power profile and optical performance of 2 extended range-of-vision (ERV) intraocular lenses (IOLs), TECNIS Eyhance (ICB00) and LuxSmart, and compare them with their monofocal counterpart lenses with similar platforms and materials: TECNIS 1-piece (ZCB00) and LuxGood, respectively.Setting: Optics and Optometry Faculties of Complutense University (Madrid) and Universitat Politècnica de Catalunya BarcelonaTech (Terrassa) in Spain.Design: Laboratory investigation on optical bench.Methods: For each design, the power distribution and (fourth and sixth-order) spherical aberration (SA) across the lens aperture were measured as well as the optical performance using modulation transfer function–based metrics with through-focus evaluation. 3 nominal powers (+10.00 diopters [D], +20.00 D, and +30.00 D) and 3 pupil sizes (2.0 mm, 3.0 mm, and 4.5 mm) were considered to assess whether the base power of the lens and pupillary dynamics have an influence on the depth-of-focus extension.Results: TECNIS Eyhance and LuxSmart IOLs had different power and SA profiles, but both designs shared a positive add power in their central region in comparison with their monofocal counterparts. LuxSmart had a greater add power while TECNIS Eyhance showed higher peak optical quality but smaller depth of focus.Conclusions: Differences of focus extension between the 2 ERV IOL designs are related to differences of power and SA profile. The nominal base power of the IOLs has little effect on their optical quality. However, pupil dynamics plays a key role since it determines the effective add power and optical performance of the ERV IOLs. PB Lippincott, Williams & Wilkins - Wolters Kluwer SN 0886-3350 YR 2024 FD 2024-10-01 LK https://hdl.handle.net/20.500.14352/112430 UL https://hdl.handle.net/20.500.14352/112430 LA eng NO Vega, Fidel PhD; Garzón, Nuria PhD; García-Montero, María PhD; Millán, María S. PhD. Power profile and optical performance of two extended range-of-vision intraocular lens designs. Journal of Cataract & Refractive Surgery 50(10):p 1065-1073, October 2024. | DOI: 10.1097/j.jcrs.0000000000001528 NO Supported by Projects PID2020-114582RB-I00/AEI/10.13039/501100011033 (F.V., N.G., M.S.M.) and PID2021-122486OA-I00 (M.G.-M., N.G.) from the Spanish Agencia Estatal de Investigación.Submitted: January 25, 2024 | Final revision submitted: July 6, 2024 | Accepted: July 10, 2024 NO Ministerio de Ciencia e Innovación (España) DS Docta Complutense RD 2 ago 2025