RT Conference Proceedings T1 Reliability of retinopathy of prematurity diagnosis by analyzing digital images using telemedicine system. T2 Fiabilidad del diagnóstico de la retinopatía del prematuro mediante el análisis de imágenes digitales utilizando un sistema de telemedicina. A1 Navarro Blanco, Carolina A1 Chamorro Gutiérrez, E. A1 Bonnin Arias, Cristina Natalia A1 Pastora Salvador, Natalia A1 Graboska, A. A1 Amorena, G. A1 Sánchez Ramos, Celia AB PURPOSE: To evaluate interobserver´s concordance in retinopathy of prematurity diagnosis and treatment by analyzing digital images.MATERIALS AND METHODS: descriptive, comparative observational study. The study sample was made up of 14 reconstructed retinal pictures obteined in 5 eyes of 3 low-birth-weight infants taken using a wide-angle fundus digital camera Retcam 120 (Clarity Medical Systems, Pleasanton, CA). All the images were examined by 1 experinced ophthalmologist and 6 ophthalmologist trained previously in digital image analysis. Retinographies were graded according to the systems Interantional Classification of Retinopathy of Prematurity revisited (ICROP) and Early Treatment for Retinopathy of Prematurity (ETROP). Interobserver´s concordance was assessed for each of the 6 specialist ophthalmologists regarding the ROP. YR 2011 FD 2011-11-05 LK https://hdl.handle.net/20.500.14352/108657 UL https://hdl.handle.net/20.500.14352/108657 LA eng DS Docta Complutense RD 6 abr 2025