TY - JOUR AU - Gómez Polo, Miguel Ángel AU - Borga Donmez, Mustafa AU - Çakmak, Gülce AU - Yilmaz, Burak AU - Revilla-León, Marta PY - 2023 DO - 10.1111/jopr.13774 SN - 1059-941X UR - https://hdl.handle.net/20.500.14352/94075 T2 - Journal of Prosthodontics AB - Purpose: To evaluate the influence of implant scan body (ISB) design (height, diameter, geometry, material, and retention system) on the accuracy of digital implant scans.Material and methods: A literature search was completed in five databases:... LA - eng M2 - 165 PB - Wiley KW - Accuracy KW - Digital impression KW - Implant scan body KW - Prosthodontics TI - Influence of implant scan body design (height, diameter, geometry, material, and retention system) on intraoral scanning accuracy: a systematic review TY - journal article VL - 32 ER -