RT Journal Article T1 Intraocular lens power calculation in eyes with keratoconus A1 Garzón Jiménez, Nuria A1 Arriola Villalobos, Pedro A1 Felipe Márquez, Gema A1 Poyales Galán, Francisco A1 García Montero, María AB The purpose was to review and document the methods used to calculate the power of the intraocular lens (IOL) to be implanted in cataract surgery in the specific scenario of eyes with keratoconus (KC). This review was conducted of all scientific articles published in English that focused on the parameters and formulas used to calculate the power of the IOL to be implanted in eyes with KC undergoing cataract surgery. There are few publications that show in detail how IOL power is calculated in those particular cases. If the keratometric value is used based on the standard refractive index (1.3375), this results in a postoperative refractive error with a tendency to hyperopia. The SRK/T formula is the formula yielding the best outcomes. The greater the severity of KC, the greater the deviation of the postoperative refractive status deviation from the target outcome. PB Wolters Kluwer SN 1873-4502 YR 2020 FD 2020 LK https://hdl.handle.net/20.500.14352/6023 UL https://hdl.handle.net/20.500.14352/6023 LA eng NO Review/Update DS Docta Complutense RD 7 may 2024