RT Journal Article T1 Comparison of the Hemodynamic Performance of the Balloon-expandable SAPIEN 3 Versus Self-expandable Evolut R Transcatheter Valve: A Case-matched Study A1 Enríquez Rodríguez, Eduardo A1 Amat Santos, Ignacio J. A1 Jiménez Quevedo, Pilar A1 Martín Morquecho, Irene A1 Tirado Conte, Gabriela A1 Pérez-Vizcayno, María José A1 Gómez de Diego, José Juan A1 Arnold, Roman A1 Aldazábal, Andrés A1 Rojas, Paol A1 Agustín, Alberto de A1 Trigo, María Del A1 Gutiérrez, Hipólito A1 San Román, José A. A1 Macaya Miguel, Carlos A1 Nombela Franco, Luis AB Introduction and objectives: The SAPIEN 3 (S3) valve and the Medtronic Evolut R (EVR) are secondgeneration transcatheter valves, designed to further reduce the rate of paravalvular aortic regurgitation(AoR). The aim of this study was to compare the 2 devices in terms of valve performance in a casematched study with independent echocardiographic analysis.Methods: Of a population of 201 patients who underwent transcatheter aortic valve implantation,144 patients (S3, n = 80; EVR, n = 64) were matched according to aortic annulus diameter and aortic valvecalcium score, as assessed by computed tomography. All echocardiographic examinations collected atbaseline and at 1- and 6-month follow-up were centrally analyzed.Results: The 2 groups were well balanced in baseline clinical and echocardiographic characteristics. TheEVR valve showed a better hemodynamic profile as assessed by peak aortic gradient (EVR 13 7 vsS3 20 10 mmHg; P < .001), mean aortic gradient (EVR 7 3 vs S3 11 6 mmHg; P < .001), and Dopplervelocity index (EVR 0.65 0.15 vs S3 0.51 0.16; P < .001). The rate of moderate-severe or any paravalvular( mild) AoR was higher in the EVR group (11% and 50%) than in the S3 group (2.5% and 21%; P < .05,respectively), with a larger number of paravalvular jets (P < .001).Conclusions: In a case-matched cohort of transcatheter aortic valve implantation patients, the S3 valve wasassociatedwitha lower rate ofparavalvularAoR but alsowithahigher residual gradientthanthe EVRsystem. PB Elsevier YR 2017 FD 2017-11-28 LK https://hdl.handle.net/20.500.14352/133626 UL https://hdl.handle.net/20.500.14352/133626 LA eng NO Enríquez-Rodríguez E, Amat-Santos IJ, Jiménez-Quevedo P, Martín-Morquecho I, Tirado-Conte G, Pérez-Vizcayno MJ, et al. Comparación de la hemodinámica valvular de la prótesis transcatéter con balón expandible SAPIEN 3 frente a la autoexpandible Evolut R: estudio de casos emparejados. Revista Española de Cardiología 2018;71:735–42. https://doi.org/10.1016/j.recesp.2017.10.032 DS Docta Complutense RD 5 mar 2026