<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-06-08T03:45:45Z</responseDate><request verb="GetRecord" identifier="oai:docta.ucm.es:20.500.14352/103535" metadataPrefix="qdc">https://docta.ucm.es/rest/oai/request</request><GetRecord><record><header><identifier>oai:docta.ucm.es:20.500.14352/103535</identifier><datestamp>2025-03-18T15:05:53Z</datestamp><setSpec>com_20.500.14352_14</setSpec><setSpec>col_20.500.14352_15</setSpec></header><metadata><qdc:qualifieddc xmlns:qdc="http://dspace.org/qualifieddc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://purl.org/dc/elements/1.1/ http://dublincore.org/schemas/xmls/qdc/2006/01/06/dc.xsd http://purl.org/dc/terms/ http://dublincore.org/schemas/xmls/qdc/2006/01/06/dcterms.xsd http://dspace.org/qualifieddc/ http://www.ukoln.ac.uk/metadata/dcmi/xmlschema/qualifieddc.xsd">
   <dc:title>Calibration of Sensor Network for Outdoor Measurement of PM2.5 on High Wood-Heating Smoke in Temuco City</dc:title>
   <dc:creator>Muñoz Poblete, Carlos Omar</dc:creator>
   <dc:creator>Huircan Quilaqueo, Juan Ignacio</dc:creator>
   <dc:creator>Jaramillo Montoya, Francisco</dc:creator>
   <dc:creator>Boso Gaspar, Àlex</dc:creator>
   <dc:contributor>Trucillo, Paolo</dc:contributor>
   <dcterms:abstract>In order to ascertain the spatial and temporal changes in the air quality in Temuco City, Chile, we created and installed a network of inexpensive sensors to detect PM2.5 particulate matter. The 21 measurement points deployed were based on a low-cost Sensiron SPS30 sensor, complemented with temperature and humidity sensors, an Esp32 microcontroller card with LoRa and WiFi wireless communication interface, and a solar charging unit. The units were calibrated using an airtight combustion chamber with a Grimm 11-E as a reference unit. The calibration procedure fits the parameters of a calibration model to map the raw low-cost particle-material measurements into reliable calibrated values. The measurements showed that the concentrations of fine particulate material recorded in Temuco present a high temporal and spatial variability. In critical contamination episodes, pollution reaches values as high as 354 µg/m3, and at the same time, it reaches 50 µg/m3  in other parts of the city. The contamination episodes show a similar trend around the city, and the peaks are in the time interval from 07:00 PM to 1:00 AM. In the winter, this time of day coincides with when families are usually home and there are low temperatures outside</dcterms:abstract>
   <dcterms:dateAccepted>2024-04-25T17:16:34Z</dcterms:dateAccepted>
   <dcterms:available>2024-04-25T17:16:34Z</dcterms:available>
   <dcterms:created>2024-04-25T17:16:34Z</dcterms:created>
   <dcterms:issued>2023-08-03</dcterms:issued>
   <dc:type>journal article</dc:type>
   <dc:identifier>https://hdl.handle.net/20.500.14352/103535</dc:identifier>
   <dc:identifier>XXXX-XXXX</dc:identifier>
   <dc:identifier>10.3390/pr11082338</dc:identifier>
   <dc:identifier>2227-9717</dc:identifier>
   <dc:language>eng</dc:language>
   <dc:relation>info:eu-repo/grantAgreement/IDI18-0003</dc:relation>
   <dc:relation>info:eu-repo/grantAgreement/FB210024</dc:relation>
   <dc:relation>Muñoz, C.; Huircan, J.; Jaramillo, F.; Boso, Á. Calibration of Sensor Network for Outdoor Measurement of PM2.5 on High Wood-Heating Smoke in Temuco City. Processes 2023, 11, 2338. https://doi.org/10.3390/ pr1108233</dc:relation>
   <dc:rights>https://creativecommons.org/licenses/by/4.0/</dc:rights>
   <dc:rights>open access</dc:rights>
   <dc:rights>Attribution 4.0 International</dc:rights>
   <dc:publisher>MDPI</dc:publisher>
</qdc:qualifieddc></metadata></record></GetRecord></OAI-PMH>