<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-06-08T09:41:12Z</responseDate><request verb="GetRecord" identifier="oai:docta.ucm.es:20.500.14352/108953" metadataPrefix="oai_dc">https://docta.ucm.es/rest/oai/request</request><GetRecord><record><header><identifier>oai:docta.ucm.es:20.500.14352/108953</identifier><datestamp>2025-03-18T15:05:55Z</datestamp><setSpec>com_20.500.14352_14</setSpec><setSpec>col_20.500.14352_20</setSpec></header><metadata><oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
   <dc:title>Reproducibility of non-mydriatic retinographies.</dc:title>
   <dc:title>Reproducibilidad de las retinografías no midriáticas.</dc:title>
   <dc:creator>Ramirez Mercado, G.</dc:creator>
   <dc:creator>Bonnin Arias, Cristina Natalia</dc:creator>
   <dc:creator>Navarro Valls, J.J.</dc:creator>
   <dc:creator>González Montero, María Guadalupe</dc:creator>
   <dc:creator>Martín Pérez, Yolanda</dc:creator>
   <dc:creator>Sánchez Ramos, Celia</dc:creator>
   <dc:subject>535.31</dc:subject>
   <dc:subject>617.751-072.7</dc:subject>
   <dc:subject>reproducibility</dc:subject>
   <dc:subject>Non-mydriatic retinographies</dc:subject>
   <dc:subject>Óptica y optometría</dc:subject>
   <dc:subject>Óptica geométrica e instrumental</dc:subject>
   <dc:subject>2209 Óptica</dc:subject>
   <dc:subject>2209.15 Optometría</dc:subject>
   <dc:description>PURPOSE: The purpose is to know the stability of the taken registries basic of eye by means of non-Mydriatic retinography.
METHODS: The sample has been of 20 eyes of young people of both sexes between 19 and 35 years old. The measurements were carried out with a non-mydriatic retinal camera model Topcon TRC-NWS in mesopic conditions maintaining the fixation point stable. The number of times in wich each eye was measured was 10- Two condinates in each of the five points determined were located points that are P1_First intersection point between the nasal vein superior and pupilla, P2_ Fist intersection point between the nasal Artery inferior with pupila. P3_First intersection point of the nasal vein inferior with papila (the direction always was according to the needles of the clock); P4_ First bifurcation nasal vein; P5_ superior_First Bifurcation nasal artery superior. For the static analysis was used the stagraphics.
CONCLUSION: The reproducibility of the registries of non-mydriatic retinal camera is very elevated for the selected points. These reseults enable us to consider the retina as a key element to implement in new security devices.</dc:description>
   <dc:description>Depto. de Optometría y Visión</dc:description>
   <dc:description>Fac. de Óptica y Optometría</dc:description>
   <dc:description>TRUE</dc:description>
   <dc:description>pub</dc:description>
   <dc:date>2024-10-14T15:21:36Z</dc:date>
   <dc:date>2024-10-14T15:21:36Z</dc:date>
   <dc:date>2010-10-09</dc:date>
   <dc:type>conference poster</dc:type>
   <dc:type>AM</dc:type>
   <dc:identifier>https://hdl.handle.net/20.500.14352/108953</dc:identifier>
   <dc:identifier>XXXX-XXXX</dc:identifier>
   <dc:language>eng</dc:language>
   <dc:rights>open access</dc:rights>
   <dc:format>application/pdf</dc:format>
</oai_dc:dc></metadata></record></GetRecord></OAI-PMH>