<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-06-08T09:41:12Z</responseDate><request verb="GetRecord" identifier="oai:docta.ucm.es:20.500.14352/108953" metadataPrefix="qdc">https://docta.ucm.es/rest/oai/request</request><GetRecord><record><header><identifier>oai:docta.ucm.es:20.500.14352/108953</identifier><datestamp>2025-03-18T15:05:55Z</datestamp><setSpec>com_20.500.14352_14</setSpec><setSpec>col_20.500.14352_20</setSpec></header><metadata><qdc:qualifieddc xmlns:qdc="http://dspace.org/qualifieddc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://purl.org/dc/elements/1.1/ http://dublincore.org/schemas/xmls/qdc/2006/01/06/dc.xsd http://purl.org/dc/terms/ http://dublincore.org/schemas/xmls/qdc/2006/01/06/dcterms.xsd http://dspace.org/qualifieddc/ http://www.ukoln.ac.uk/metadata/dcmi/xmlschema/qualifieddc.xsd">
   <dc:title>Reproducibility of non-mydriatic retinographies.</dc:title>
   <dc:creator>Ramirez Mercado, G.</dc:creator>
   <dc:creator>Bonnin Arias, Cristina Natalia</dc:creator>
   <dc:creator>Navarro Valls, J.J.</dc:creator>
   <dc:creator>González Montero, María Guadalupe</dc:creator>
   <dc:creator>Martín Pérez, Yolanda</dc:creator>
   <dc:creator>Sánchez Ramos, Celia</dc:creator>
   <dcterms:abstract>PURPOSE: The purpose is to know the stability of the taken registries basic of eye by means of non-Mydriatic retinography.
METHODS: The sample has been of 20 eyes of young people of both sexes between 19 and 35 years old. The measurements were carried out with a non-mydriatic retinal camera model Topcon TRC-NWS in mesopic conditions maintaining the fixation point stable. The number of times in wich each eye was measured was 10- Two condinates in each of the five points determined were located points that are P1_First intersection point between the nasal vein superior and pupilla, P2_ Fist intersection point between the nasal Artery inferior with pupila. P3_First intersection point of the nasal vein inferior with papila (the direction always was according to the needles of the clock); P4_ First bifurcation nasal vein; P5_ superior_First Bifurcation nasal artery superior. For the static analysis was used the stagraphics.
CONCLUSION: The reproducibility of the registries of non-mydriatic retinal camera is very elevated for the selected points. These reseults enable us to consider the retina as a key element to implement in new security devices.</dcterms:abstract>
   <dcterms:dateAccepted>2024-10-14T15:21:36Z</dcterms:dateAccepted>
   <dcterms:available>2024-10-14T15:21:36Z</dcterms:available>
   <dcterms:created>2024-10-14T15:21:36Z</dcterms:created>
   <dcterms:issued>2010-10-09</dcterms:issued>
   <dc:type>conference poster</dc:type>
   <dc:identifier>https://hdl.handle.net/20.500.14352/108953</dc:identifier>
   <dc:identifier>XXXX-XXXX</dc:identifier>
   <dc:language>eng</dc:language>
   <dc:rights>open access</dc:rights>
</qdc:qualifieddc></metadata></record></GetRecord></OAI-PMH>