<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-06-01T02:13:36Z</responseDate><request verb="GetRecord" identifier="oai:docta.ucm.es:20.500.14352/109317" metadataPrefix="oai_dc">https://docta.ucm.es/rest/oai/request</request><GetRecord><record><header><identifier>oai:docta.ucm.es:20.500.14352/109317</identifier><datestamp>2024-10-28T14:12:50Z</datestamp><setSpec>com_20.500.14352_14</setSpec><setSpec>col_20.500.14352_15</setSpec></header><metadata><oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
   <dc:title>Influence of the ambient color lighting on the accuracy of complete arch implant scans recorded by using two intraoral scanners</dc:title>
   <dc:creator>Ochoa López, Gastón</dc:creator>
   <dc:creator>Revilla León, Marta</dc:creator>
   <dc:creator>Gómez Polo, Miguel Ángel</dc:creator>
   <dc:subject>616.314-089.843</dc:subject>
   <dc:subject>Color lighting</dc:subject>
   <dc:subject>Complete arch</dc:subject>
   <dc:subject>Dental implants</dc:subject>
   <dc:subject>Intraoral scanners</dc:subject>
   <dc:subject>Odontología (Odontología)</dc:subject>
   <dc:subject>Implantes dentales</dc:subject>
   <dc:subject>3213.13 Ortodoncia-Estomatología</dc:subject>
   <dc:description>Objectives: To measure the influence of scanning pattern on the accuracy, time, and number of photograms of complete-arch intraoral implant scans.

Methods: A maxillary edentulous patient with 7 implants was selected. The reference implant cast was obtained using conventional methods (7Series Scanner). Four groups were created based on the scanning pattern used to acquire the complete-arch implant scans by using an intraoral scanner (IOS) (Trios4): manufacturer’s recom- mended (Occlusal-Buccal-Lingual (OBL)), zig-zag (Zig-zag), circumferential (Circumf), and novel pattern that included locking an initial occlusal scan (O-Lock group) (n = 15). Scanning time and number of photograms were recorded. The linear and angular measurements were used to assess scanning accuracy. One-way ANOVA and Tukey tests were used to analyze trueness, scanning time, and number of photograms. The Levene test was selected to assess precision (α=0.05).

Results: Statistically significant differences in trueness were detected among OBL, Zig-zag, Circumf, and O-Lock regarding linear discrepancy (P &lt; 0.01), angular discrepancy (P &lt; 0.01), scanning time (P &lt; 0.01), and number of photograms (P &lt; 0.01). The O-Lock (63 ± 20 μm) showed the best linear trueness with statistically significant differences (P &lt; 0.01) with Circumferential (86 ± 16 μm) and OBL (87 ± 19 μm) groups. The O-Lock (93.5 ± 13.4 s, 1080 ± 104 photograms) and Circumf groups (102.9 ± 15.1 s, 1112 ± 179 photograms) obtained lower scanning times (P &lt; 0.01) and number of photograms (P &lt; 0.01) than OBL (130.3 ± 19.4 s, 1293 ± 161 pho- tograms) and Zig-zag (125.7 ± 22.1 s, 1316 ± 160 photograms) groups.

Conclusions: The scanning patterns tested influenced scanning accuracy, time, and number of photograms of the complete-arch scans obtained by using the IOS tested. The zig-zag and O-Lock scanning patterns are recom- mended to obtain complete-arch implant scans when using the selected IOS.</dc:description>
   <dc:description>Depto. de Odontología Conservadora y Prótesis</dc:description>
   <dc:description>Fac. de Odontología</dc:description>
   <dc:description>TRUE</dc:description>
   <dc:description>inpress</dc:description>
   <dc:description>APC financiada por la UCM</dc:description>
   <dc:date>2024-10-23T11:56:03Z</dc:date>
   <dc:date>2024-10-23T11:56:03Z</dc:date>
   <dc:date>2024-04-30</dc:date>
   <dc:type>journal article</dc:type>
   <dc:identifier>https://hdl.handle.net/20.500.14352/109317</dc:identifier>
   <dc:identifier>0022-3913</dc:identifier>
   <dc:identifier>10.1016/j.prosdent.2024.03.030</dc:identifier>
   <dc:language>eng</dc:language>
   <dc:relation>Ochoa-López G, Revilla-León M, Gómez-Polo M. Influence of the ambient color lighting on the accuracy of complete arch implant scans recorded by using two intraoral scanners. J Prosthet Dent. 2024 Apr 22:S0022-3913(24)00224-5. doi: 10.1016/j.prosdent.2024.03.030. Epub ahead of print. PMID: 38653690.</dc:relation>
   <dc:rights>open access</dc:rights>
   <dc:format>application/pdf</dc:format>
   <dc:publisher>Elsevier</dc:publisher>