<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-06-08T04:19:13Z</responseDate><request verb="GetRecord" identifier="oai:docta.ucm.es:20.500.14352/118055" metadataPrefix="marc">https://docta.ucm.es/rest/oai/request</request><GetRecord><record><header><identifier>oai:docta.ucm.es:20.500.14352/118055</identifier><datestamp>2025-03-18T12:11:17Z</datestamp><setSpec>com_20.500.14352_14</setSpec><setSpec>col_20.500.14352_15</setSpec></header><metadata><record xmlns="http://www.loc.gov/MARC21/slim" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
   <leader>00925njm 22002777a 4500</leader>
   <datafield ind2=" " ind1=" " tag="042">
      <subfield code="a">dc</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="720">
      <subfield code="a">Albero-Ros, Elsa</subfield>
      <subfield code="e">author</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="720">
      <subfield code="a">Lorente Velázquez, Amalia</subfield>
      <subfield code="e">author</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="720">
      <subfield code="a">Madrid Costa, David</subfield>
      <subfield code="e">author</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="720">
      <subfield code="a">González Pérez, Mariano</subfield>
      <subfield code="e">author</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="260">
      <subfield code="c">2025-01</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="520">
      <subfield code="a">Purpose: To create a valid and reliable computer-adaptive testing (CAT) tool for assessing Multifocal Contact Lens (MCL) performance in presbyopic individuals, ensuring high precision. The self-administered tool will initially be accessible online in Spanish.

Methods: Five steps were followed for the correct development of the instruments: item bank development, item refinement phase, item response theory calibration of the refined item bank, CAT simulations and design, and an initial validation study. A total of 1163 presbyopic patients were involved in the over-all study. Convergent validity was assessed by comparing results to the CLDQ-8 questionnaire, and repeatability assessment was performed two weeks after the initial completion.

Results: The final item bank consisted of 108 items assessing various relevant domains for MCL performance evaluation. The calibration study showed a person separation index of 4.69 and a reliability of 0.96 along with a measurement precision of 0.27. The final CAT distinguished between 16 levels of MCL performance by presenting an average of 10.61 ± 1.00 items per patient, with an average completion time of 3:04 ± 1:24 min. Signs of convergent validity showed a correlation of 0.73 and repeatability was assessed showing an intraclass Correlation Coefficient of 0.881 with a 95% Confidence Interval 0,815-0,924, and Limits of Agreement of ± 1.07.

Conclusion: The MCL-PRO-CAT is a groundbreaking tool for evaluating MCL performance in presbyopic individuals. With automated scoring and fewer items, it was feasible, valid, and precise, enhancing clinical practicality.</subfield>
   </datafield>
   <datafield ind1="8" ind2=" " tag="024">
      <subfield code="a">Albero-Ros E, Lorente-Velázquez A, Madrid-Costa D, González-Pérez M. Development and Initial Validation of the MCL-PRO-CAT: A computerized adaptive test designed to measure multifocal contact lens performance from the patient's perspective. Cont Lens Anterior Eye. 2025 Jan 31:102378. doi: 10.1016/j.clae.2025.102378. Epub ahead of print. PMID: 39893061.</subfield>
   </datafield>
   <datafield ind1="8" ind2=" " tag="024">
      <subfield code="a">10.1016/j.clae.2025.102378</subfield>
   </datafield>
   <datafield ind1="8" ind2=" " tag="024">
      <subfield code="a">https://hdl.handle.net/20.500.14352/118055</subfield>
   </datafield>
   <datafield ind1="8" ind2=" " tag="024">
      <subfield code="a">https://doi.org/10.1016/j.clae.2025.102378</subfield>
   </datafield>
   <datafield ind2="0" ind1="0" tag="245">
      <subfield code="a">Development and Initial Validation of the MCL-PRO-CAT: A computerized adaptive test designed to measure multifocal contact lens performance from the patient's perspective</subfield>
   </datafield>
</record></metadata></record></GetRecord></OAI-PMH>