<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-06-08T03:24:01Z</responseDate><request verb="GetRecord" identifier="oai:docta.ucm.es:20.500.14352/118055" metadataPrefix="oai_dc">https://docta.ucm.es/rest/oai/request</request><GetRecord><record><header><identifier>oai:docta.ucm.es:20.500.14352/118055</identifier><datestamp>2025-03-18T12:11:17Z</datestamp><setSpec>com_20.500.14352_14</setSpec><setSpec>col_20.500.14352_15</setSpec></header><metadata><oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
   <dc:title>Development and Initial Validation of the MCL-PRO-CAT: A computerized adaptive test designed to measure multifocal contact lens performance from the patient's perspective</dc:title>
   <dc:creator>Albero-Ros, Elsa</dc:creator>
   <dc:creator>Lorente Velázquez, Amalia</dc:creator>
   <dc:creator>Madrid Costa, David</dc:creator>
   <dc:creator>González Pérez, Mariano</dc:creator>
   <dc:subject>617.7-089.243</dc:subject>
   <dc:subject>Computer adaptive test</dc:subject>
   <dc:subject>Multifocal contact lens performance</dc:subject>
   <dc:subject>Patient reported outcomes instrument</dc:subject>
   <dc:subject>Presbyopia</dc:subject>
   <dc:subject>Questionnaire</dc:subject>
   <dc:subject>Óptica y optometría</dc:subject>
   <dc:subject>2209.15 Optometría</dc:subject>
   <dc:description>Purpose: To create a valid and reliable computer-adaptive testing (CAT) tool for assessing Multifocal Contact Lens (MCL) performance in presbyopic individuals, ensuring high precision. The self-administered tool will initially be accessible online in Spanish.

Methods: Five steps were followed for the correct development of the instruments: item bank development, item refinement phase, item response theory calibration of the refined item bank, CAT simulations and design, and an initial validation study. A total of 1163 presbyopic patients were involved in the over-all study. Convergent validity was assessed by comparing results to the CLDQ-8 questionnaire, and repeatability assessment was performed two weeks after the initial completion.

Results: The final item bank consisted of 108 items assessing various relevant domains for MCL performance evaluation. The calibration study showed a person separation index of 4.69 and a reliability of 0.96 along with a measurement precision of 0.27. The final CAT distinguished between 16 levels of MCL performance by presenting an average of 10.61 ± 1.00 items per patient, with an average completion time of 3:04 ± 1:24 min. Signs of convergent validity showed a correlation of 0.73 and repeatability was assessed showing an intraclass Correlation Coefficient of 0.881 with a 95% Confidence Interval 0,815-0,924, and Limits of Agreement of ± 1.07.

Conclusion: The MCL-PRO-CAT is a groundbreaking tool for evaluating MCL performance in presbyopic individuals. With automated scoring and fewer items, it was feasible, valid, and precise, enhancing clinical practicality.</dc:description>
   <dc:description>Depto. de Optometría y Visión</dc:description>
   <dc:description>Fac. de Óptica y Optometría</dc:description>
   <dc:description>TRUE</dc:description>
   <dc:description>pub</dc:description>
   <dc:date>2025-02-13T13:42:59Z</dc:date>
   <dc:date>2025-02-13T13:42:59Z</dc:date>
   <dc:date>2025-01</dc:date>
   <dc:type>journal article</dc:type>
   <dc:type>VoR</dc:type>
   <dc:identifier>https://hdl.handle.net/20.500.14352/118055</dc:identifier>
   <dc:identifier>XXXX-XXXX</dc:identifier>
   <dc:identifier>10.1016/j.clae.2025.102378</dc:identifier>
   <dc:language>eng</dc:language>
   <dc:relation>Albero-Ros E, Lorente-Velázquez A, Madrid-Costa D, González-Pérez M. Development and Initial Validation of the MCL-PRO-CAT: A computerized adaptive test designed to measure multifocal contact lens performance from the patient's perspective. Cont Lens Anterior Eye. 2025 Jan 31:102378. doi: 10.1016/j.clae.2025.102378. Epub ahead of print. PMID: 39893061.</dc:relation>
   <dc:rights>restricted access</dc:rights>
   <dc:format>text/html</dc:format>
   <dc:publisher>PubMed</dc:publisher>
</oai_dc:dc></metadata></record></GetRecord></OAI-PMH>