<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-10-02T16:00:06Z</responseDate><request verb="GetRecord" identifier="oai:docta.ucm.es:20.500.14352/13089" metadataPrefix="oai_dc">https://docta.ucm.es/rest/oai/request</request><GetRecord><record><header><identifier>oai:docta.ucm.es:20.500.14352/13089</identifier><datestamp>2023-08-27T09:15:36Z</datestamp><setSpec>com_20.500.14352_14</setSpec><setSpec>col_20.500.14352_15</setSpec></header><metadata><oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
   <dc:title>Variation of Coma Aberration With Prismatic Soft Contact Lenses</dc:title>
   <dc:creator>Carpena Torres, Carlos</dc:creator>
   <dc:creator>López Alonso, José Manuel</dc:creator>
   <dc:creator>Burgos Martínez, Mercedes</dc:creator>
   <dc:creator>Carracedo Rodríguez, Juan Gonzalo</dc:creator>
   <dc:creator>Carballo Álvarez, Jesús</dc:creator>
   <dc:subject>617.7-089.243</dc:subject>
   <dc:subject>681.73</dc:subject>
   <dc:subject>612.84</dc:subject>
   <dc:subject>Coma aberration</dc:subject>
   <dc:subject>Tilt</dc:subject>
   <dc:subject>Prism</dc:subject>
   <dc:subject>Soft contact lenses</dc:subject>
   <dc:subject>Lentes de contacto</dc:subject>
   <dc:subject>Optometría</dc:subject>
   <dc:subject>3311.11 Instrumentos ópticos</dc:subject>
   <dc:subject>2209.15 Optometría</dc:subject>
   <dc:description>PURPOSE: To analyze the variation in vertical coma and the rest of ocular aberrations before and after fitting prismatic soft contact lenses (PSCL). METHODS: Thirty-seven eyes of 20 healthy subjects (24.30±2.03 years) were evaluated to analyze the variation in ocular wavefront aberrations before and after fitting PSCL of different base-down prism values (1.0, 1.5, and 2.0 prism diopters [PD]), designed to study its influence in the compensation of vertical coma aberration. A Hartmann-Shack sensor with a wavelength of 780 nm was used, considering a pupil size of 3 mm. In addition, the influence of PSCL in visual function under photopic conditions in terms of high-contrast visual acuity and contrast sensitivity was evaluated. RESULTS: There was statistically significant differences (P&lt;0.05) in ocular aberrations from first to seventh order after fitting PSCL, but only the differences in vertical tilt, horizontal tilt, defocus, vertical astigmatism, and vertical coma were clinically relevant (Strehl ratio &lt;0.8). The mean of vertical coma (μm) was 0.022±0.030 for control, 0.045±0.064 for 1.0 PD (P=0.645), 0.048±0.053 for 1.5 PD (P=0.037), and 0.074±0.047 for 2.0 PD (P&lt;0.001). The changes in visual function under photopic conditions were not clinically relevant. CONCLUSIONS: PSCL induce a magnitude of vertical coma aberration directly proportional to prism value without affecting the rest of ocular high-order aberrations.</dc:description>
   <dc:description>Depto. de Optometría y Visión</dc:description>
   <dc:description>Sección Deptal. de Óptica (Óptica)</dc:description>
   <dc:description>Fac. de Óptica y Optometría</dc:description>
   <dc:description>TRUE</dc:description>
   <dc:description>pub</dc:description>
   <dc:date>2023-06-17T13:19:40Z</dc:date>
   <dc:date>2023-06-17T13:19:40Z</dc:date>
   <dc:date>2018-11</dc:date>
   <dc:type>journal article</dc:type>
   <dc:identifier>https://hdl.handle.net/20.500.14352/13089</dc:identifier>
   <dc:identifier>1542-233X</dc:identifier>
   <dc:identifier>10.1097/ICL.0000000000000485</dc:identifier>
   <dc:language>eng</dc:language>
   <dc:rights>restricted access</dc:rights>
   <dc:format>application/pdf</dc:format>
   <dc:publisher>Wolters Kluwer</dc:publisher>
</oai_dc:dc></metadata></record></GetRecord></OAI-PMH>