<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-07-29T09:33:01Z</responseDate><request verb="GetRecord" identifier="oai:docta.ucm.es:20.500.14352/138323" metadataPrefix="oai_dc">https://docta.ucm.es/rest/oai/request</request><GetRecord><record><header><identifier>oai:docta.ucm.es:20.500.14352/138323</identifier><datestamp>2026-07-10T00:17:53Z</datestamp><setSpec>com_20.500.14352_14</setSpec><setSpec>col_20.500.14352_15</setSpec></header><metadata><oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
   <dc:title>Comparison of Visual Performance Between Two Diffractive Trifocal Intraocular Lenses.</dc:title>
   <dc:creator>Segura Duch, Gloria</dc:creator>
   <dc:creator>Oliver Gutierrez, David</dc:creator>
   <dc:creator>Arans, Mar</dc:creator>
   <dc:creator>Duch Tuesta, Susana</dc:creator>
   <dc:creator>Carpena Torres, Carlos</dc:creator>
   <dc:creator>Carracedo Rodríguez, Juan Gonzalo</dc:creator>
   <dc:creator>Andreu Andreu, David</dc:creator>
   <dc:subject>Defocus curve</dc:subject>
   <dc:subject>Diffraction</dc:subject>
   <dc:subject>Multifocality</dc:subject>
   <dc:subject>Trifocal intraocular lenses</dc:subject>
   <dc:subject>Visual acuity</dc:subject>
   <dc:subject>Óptica y optometría</dc:subject>
   <dc:subject>2209.15 Optometría</dc:subject>
   <dc:description>Background/Objectives: This study aimed to compare the visual outcomes of two diffractive trifocal intraocular lenses (IOLs): the Bi-Flex Liberty 677MY (Medicontur; Zsámbék, Hungary) and the FineVision POD F (BVI Medical; Waltham, MA, USA). Methods: A prospective study with a 3-month follow-up was conducted. A total of 62 patients were divided into two groups according to the type of lens implanted: 31 patients with the Liberty lens (61.1 ± 6.4 years) and 31 patients with the Finevision lens (61.9 ± 6.8 years). Three measurement sessions were conducted (baseline, 1 month, and 3 months). These sessions included measurements of the subjective refraction, visual acuity, and defocus curve. Both eyes of each patient were operated on and included in the statistical analysis. Results: Three months after surgery, monocular visual acuity with the Liberty lens was statistically greater than with the Finevision lens at defocus values of -2.00 D (50 cm) and -2.50 D (40 cm) (p &lt; 0.01). In this regard, the near visual acuity results (40-50 cm) with the Liberty lens showed greater variability compared to those of the Finevision lens. Binocularly, however, the Finevision lens demonstrated a statistically significant improvement in visual acuity than the Liberty lens at a defocus of -1.50 D (67 cm) (p = 0.01). Both IOLs provided visual acuities better than 0.20 logMAR for a defocus range from distance (0.00 D) to near (-3.50 D). Conclusions: Future studies are needed to investigate which patient ocular parameters could predict improved near vision with the Liberty lens or intermediate vision with the Finevision lens.</dc:description>
   <dc:description>Depto. de Optometría y Visión</dc:description>
   <dc:description>Fac. de Óptica y Optometría</dc:description>
   <dc:description>TRUE</dc:description>
   <dc:description>pub</dc:description>
   <dc:date>2026-07-09T13:41:11Z</dc:date>
   <dc:date>2026-07-09T13:41:11Z</dc:date>
   <dc:date>2025-04-30</dc:date>
   <dc:type>journal article</dc:type>
   <dc:type>VoR</dc:type>
   <dc:identifier>https://hdl.handle.net/20.500.14352/138323</dc:identifier>
   <dc:identifier>XXXX-XXXX</dc:identifier>
   <dc:identifier>10.3390/jcm14093128</dc:identifier>
   <dc:language>eng</dc:language>
   <dc:relation>Segura-Duch, G.; Oliver-Gutierrez, D.; Arans, M.; Duch-Tuesta, S.; Carpena-Torres, C.; Carracedo, G.; Andreu-Andreu, D. Comparison of Visual Performance Between Two Diffractive Trifocal Intraocular Lenses. J. Clin. Med. 2025, 14, 3128. https://doi.org/10.3390/jcm14093128</dc:relation>
   <dc:rights>Attribution-NonCommercial-NoDerivatives 4.0 International</dc:rights>
   <dc:rights>http://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights>
   <dc:rights>open access</dc:rights>
   <dc:format>application/pdf</dc:format>
   <dc:publisher>MDPI</dc:publisher>
</oai_dc:dc></metadata></record></GetRecord></OAI-PMH>