<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-06-08T10:18:00Z</responseDate><request verb="GetRecord" identifier="oai:docta.ucm.es:20.500.14352/50784" metadataPrefix="oai_dc">https://docta.ucm.es/rest/oai/request</request><GetRecord><record><header><identifier>oai:docta.ucm.es:20.500.14352/50784</identifier><datestamp>2023-08-27T07:33:55Z</datestamp><setSpec>com_20.500.14352_14</setSpec><setSpec>col_20.500.14352_15</setSpec></header><metadata><oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
   <dc:title>Three-dimensional measurement of microchips using structured light techniques</dc:title>
   <dc:creator>Quiroga Mellado, Juan Antonio</dc:creator>
   <dc:creator>Vargas Balbuena, Javier</dc:creator>
   <dc:creator>Koninckx, Thomas</dc:creator>
   <dc:creator>Van Gool, Luc</dc:creator>
   <dc:subject>535</dc:subject>
   <dc:subject>Calibration</dc:subject>
   <dc:subject>High Dynamic-Range Imaging</dc:subject>
   <dc:subject>Active Three-Dimensional Measure</dc:subject>
   <dc:subject>Microchip Inspection</dc:subject>
   <dc:subject>Óptica (Física)</dc:subject>
   <dc:subject>2209.19 Óptica Física</dc:subject>
   <dc:description>© 2008 Society of Photo-Optical Instrumentation Engineers.</dc:description>
   <dc:description>The industry dealing with microchip inspection requires fast, flexible, repeatable, and stable 3-D measuring systems. The typical devices used for this purpose are coordinate measurement machines (CMMs). These systems have limitations such as high cost, low measurement speed, and small quantity of measured 3-D points. Now optical techniques are beginning to replace the typical touch probes because of their noncontact nature, their full-field measurement capability, their high measurement density, as well as their low cost and high measurement speed. However, typical properties of microchip devices, which include a strongly spatially varying reflectance, make impossible the direct use of the classical optical 3-D measurement techniques. We present a 3-D measurement technique capable of optically measuring these devices using a camera-projector system. The proposed method improves the dynamic range of the imaging system through the use of a set of gray-code (GC) and phase- shift (PS) measures with different CCD integration times. A set of extended-range GC and PS images are obtained and used to acquire a dense 3-D measure of the object. We measure the 3-D shape of an integrated circuit and obtained satisfactory results.</dc:description>
   <dc:description>Depto. de Óptica</dc:description>
   <dc:description>Fac. de Ciencias Físicas</dc:description>
   <dc:description>TRUE</dc:description>
   <dc:description>pub</dc:description>
   <dc:date>2023-06-20T10:37:02Z</dc:date>
   <dc:date>2023-06-20T10:37:02Z</dc:date>
   <dc:date>2008-05</dc:date>
   <dc:type>journal article</dc:type>
   <dc:identifier>https://hdl.handle.net/20.500.14352/50784</dc:identifier>
   <dc:identifier>0091-3286</dc:identifier>
   <dc:identifier>10.1117/1.2919726</dc:identifier>
   <dc:rights>metadata only access</dc:rights>
   <dc:publisher>Spie-Soc Photo-Optical Instrumentation Engineers</dc:publisher>
</oai_dc:dc></metadata></record></GetRecord></OAI-PMH>