<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-06-27T01:02:17Z</responseDate><request verb="GetRecord" identifier="oai:docta.ucm.es:20.500.14352/52011" metadataPrefix="marc">https://docta.ucm.es/rest/oai/request</request><GetRecord><record><header><identifier>oai:docta.ucm.es:20.500.14352/52011</identifier><datestamp>2024-09-23T16:22:03Z</datestamp><setSpec>com_20.500.14352_14</setSpec><setSpec>col_20.500.14352_15</setSpec></header><metadata><record xmlns="http://www.loc.gov/MARC21/slim" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
   <leader>00925njm 22002777a 4500</leader>
   <datafield ind2=" " ind1=" " tag="042">
      <subfield code="a">dc</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="720">
      <subfield code="a">Aguilar Martínez, R.</subfield>
      <subfield code="e">author</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="720">
      <subfield code="a">Palacios Corvillo, María Antonia</subfield>
      <subfield code="e">author</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="720">
      <subfield code="a">Greenwood, R.</subfield>
      <subfield code="e">author</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="720">
      <subfield code="a">Mills, G.A.</subfield>
      <subfield code="e">author</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="720">
      <subfield code="a">Vrana, B.</subfield>
      <subfield code="e">author</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="720">
      <subfield code="a">Gómez Gómez, María Milagros</subfield>
      <subfield code="e">author</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="260">
      <subfield code="c">2008</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="520">
      <subfield code="a">An integrative passive sampler (Chemcatcher®) consisting of a 47 mm C18 Empore™ disk as the receiving phase overlaid with a thin cellulose acetate diffusion membrane was developed and calibrated for the measurement of time-weighted average water concentrations of organotin compounds [monobutyltin (MBT), dibutyltin (DBT), tributlytin (TBT) and triphenyltin (TPhT)] in water. The effect of water temperature and turbulence on the uptake rate of these analytes was evaluated in the laboratory using a flow-through tank. Uptake was linear over a 14-day period being in the range: MBT (3–23 mL day−1), DBT (40–200 mL day−1), TBT (30–200 mL day−1) and TPhT (30–190 mL day−1) for all the different conditions tested. These sampling rates were high enough to permit the use of the Chemcatcher® to monitor levels of organotin compounds typically found in polluted aquatic environments. Using gas chromatography (GC) with either ICP-MS or flame photometric detection, limits of detection for the device (14-day deployment) for the different organotin compounds in water were in the range of 0.2–7.5 ng L−1, and once accumulated in the receiving phase the compounds were stable over prolonged periods. Due to anisotropic exchange kinetics, performance reference compounds could not be used with this passive sampling system to compensate for changes in sampling rate due to variations in water temperature, turbulence and biofouling of the surface of the diffusion membrane during field deployments. The performance of the Chemcatcher® was evaluated alongside spot water sampling in Alicante Habour, Spain which is known to contain elevated levels of organotin compounds. The samplers provided time-weighted average concentrations of the bioavailable fractions of the tin compounds where environmental concentrations fluctuated markedly in time.</subfield>
   </datafield>
   <datafield ind1="8" ind2=" " tag="024">
      <subfield code="a">1873-4324 (Online) 0003-2670 (Print)</subfield>
   </datafield>
   <datafield ind1="8" ind2=" " tag="024">
      <subfield code="a">doi.org/10.1016/j.aca.2008.04.052</subfield>
   </datafield>
   <datafield ind1="8" ind2=" " tag="024">
      <subfield code="a">https://hdl.handle.net/20.500.14352/52011</subfield>
   </datafield>
   <datafield ind1="8" ind2=" " tag="024">
      <subfield code="a">http://www.sciencedirect.com/science/article/pii/S0003267008008039</subfield>
   </datafield>
   <datafield ind2="0" ind1="0" tag="245">
      <subfield code="a">Calibration and use of the Chemcatcher® passive sampler
for monitoring organotin compounds in water</subfield>
   </datafield>
</record></metadata></record></GetRecord></OAI-PMH>