<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-06-28T10:31:57Z</responseDate><request verb="GetRecord" identifier="oai:docta.ucm.es:20.500.14352/72980" metadataPrefix="qdc">https://docta.ucm.es/rest/oai/request</request><GetRecord><record><header><identifier>oai:docta.ucm.es:20.500.14352/72980</identifier><datestamp>2025-11-26T01:19:56Z</datestamp><setSpec>com_20.500.14352_14</setSpec><setSpec>col_20.500.14352_15</setSpec></header><metadata><qdc:qualifieddc xmlns:qdc="http://dspace.org/qualifieddc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://purl.org/dc/elements/1.1/ http://dublincore.org/schemas/xmls/qdc/2006/01/06/dc.xsd http://purl.org/dc/terms/ http://dublincore.org/schemas/xmls/qdc/2006/01/06/dcterms.xsd http://dspace.org/qualifieddc/ http://www.ukoln.ac.uk/metadata/dcmi/xmlschema/qualifieddc.xsd">
   <dc:title>Beam-Shaping Extended Depth of Focus Intraocular Lens: Optical Assessment With Corneas of Increasing Spherical Aberration</dc:title>
   <dc:creator>Madrid Costa, David</dc:creator>
   <dc:creator>Fernández Vega-Cueto, Luis</dc:creator>
   <dc:creator>Azor-Morón, Juan Antonio</dc:creator>
   <dc:creator>Vega Lerin, Fidel</dc:creator>
   <dc:creator>Millán García-Varela, María Sagrario</dc:creator>
   <dc:creator>Alfonso, José F.</dc:creator>
   <dcterms:abstract>PURPOSE:To assess the optical quality and halo formation of a beam-shaping extended depth-of-focus (EDOF) intraocular lens (IOL) (AcrySof IQ Vivity; Alcon Laboratories, Inc) with corneas of long-range spherical aberration (SA) such as those resulting from myopic laser ablations.
METHODS:The optical quality of the EDOF IOL and a reference monofocal IOL was evaluated with three corneas (A, B, and C, with SA =+0.135, +0.290, +0.540 µm, respectively, for a 5.15-mm pupil at the IOL plane). The through-focus modulation transfer function area (MTFa) curves were obtained between −5.00 and +2.00 diopters (D) defocus range. The halo was also assessed with the three corneas.
RESULTS:Through-focus MTFa curves for a 4.5-mm IOL pupil showed a slight decrease in the maximum MTFa value provided by the EDOF IOL compared to the monofocal IOL in the three corneal situations (A: 45.9 vs 38.6 units; B: 41.1 vs 33.1 units, and C: 26.9 vs 23.8 units). For the 3.0-mm pupil, the EDOF IOL also had lower maximum MTFa than the monofocal IOL; however, the depth-of-focus increased to −2.20 D. With corneas A and B, the halo induced was of low energy with both IOLs. With cornea C, the EDOF IOL created a much larger and intense halo.
CONCLUSIONS:The EDOF IOL provided a good distance optical performance and an extended range of focus of approximately 2.00 D, with a halo of low intensity when evaluated with a corneal SA similar to the one induced by a low to moderate myopic ablation. With a high myopic ablation, the halo induced would be of considerable size and energy.</dcterms:abstract>
   <dcterms:dateAccepted>2023-06-22T12:38:40Z</dcterms:dateAccepted>
   <dcterms:available>2023-06-22T12:38:40Z</dcterms:available>
   <dcterms:created>2023-06-22T12:38:40Z</dcterms:created>
   <dcterms:issued>2023-02-01</dcterms:issued>
   <dc:type>journal article</dc:type>
   <dc:identifier>https://hdl.handle.net/20.500.14352/72980</dc:identifier>
   <dc:identifier>1081-597X</dc:identifier>
   <dc:identifier>10.3928/1081597X-20221215-02</dc:identifier>
   <dc:language>eng</dc:language>
   <dc:relation>info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/PID2020-114582RB-I00/ES/IMPLANTES OPTICOS INTRAOCULARES CORRECTORES DE LA PRESBICIA PARA UNA COMPENSACION VISUAL PERSONALIZADA/</dc:relation>
   <dc:relation>Madrid-Costa D, Fernández-Vega-Cueto L, Azor-Morón JA, Vega F, Millán MS, Alfonso JF. Beam-Shaping Extended Depth of Focus Intraocular Lens: Optical Assessment With Corneas of Increasing Spherical Aberration. Journal of Refractive Surgery. 2023;39(2):95-102. doi:10.3928/1081597X-20221215-02</dc:relation>
   <dc:rights>restricted access</dc:rights>
   <dc:rights>open access</dc:rights>
   <dc:publisher>Slack Incorporated</dc:publisher>
</qdc:qualifieddc></metadata></record></GetRecord></OAI-PMH>