<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-06-29T16:48:45Z</responseDate><request verb="GetRecord" identifier="oai:docta.ucm.es:20.500.14352/95444" metadataPrefix="rdf">https://docta.ucm.es/rest/oai/request</request><GetRecord><record><header><identifier>oai:docta.ucm.es:20.500.14352/95444</identifier><datestamp>2024-07-18T23:53:35Z</datestamp><setSpec>com_20.500.14352_14</setSpec><setSpec>col_20.500.14352_15</setSpec></header><metadata><rdf:RDF xmlns:rdf="http://www.openarchives.org/OAI/2.0/rdf/" xmlns:ow="http://www.ontoweb.org/ontology/1#" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:ds="http://dspace.org/ds/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/rdf/ http://www.openarchives.org/OAI/2.0/rdf.xsd">
   <ow:Publication rdf:about="oai:docta.ucm.es:20.500.14352/95444">
      <dc:title>Rapid endoglin determination in serum samples using an amperometric magneto-actuated disposable immunosensing platform</dc:title>
      <dc:creator>Torrente Rodríguez, Rebeca Magnolia</dc:creator>
      <dc:creator>Campuzano Ruiz, Susana</dc:creator>
      <dc:creator>Ruiz Valdepeñas Montiel, Víctor</dc:creator>
      <dc:creator>Pedrero Muñoz, María</dc:creator>
      <dc:creator>Fernández Aceñero, María Jesús</dc:creator>
      <dc:creator>Barderas Manchado, Rodrigo</dc:creator>
      <dc:creator>Pingarrón Carrazón, José Manuel</dc:creator>
      <dc:description>A sensitive and rapid method for the determination of the clinically relevant biomarker human endoglin (CD105) in serum samples is presented, involving a magneto-actuated immunoassay and amperometric detection at disposable screen-printed carbon electrodes (SPCEs). Micro-sized magnetic particles were modified with a specific antibody to selectively capture the target protein which was further sandwiched with a secondary HRP-labeled antibody. The immunocomplexes attached to the magnetic carriers were amperometrically detected at SPCEs using the hydroquinone (HQ)/H2O2/HRP system. The magneto-actuated immunosensing platform was able to detect 5 pmoles of endoglin (in 25μL of sample, 0.2μM) in 30min providing statistically similar results to those obtained using a commercial ELISA kit for the determination of endogenous content of endoglin in human serum samples.</dc:description>
      <dc:date>2024-01-25T12:53:18Z</dc:date>
      <dc:date>2024-01-25T12:53:18Z</dc:date>
      <dc:date>2016</dc:date>
      <dc:type>journal article</dc:type>
      <dc:identifier>Torrente-Rodríguez RM, Campuzano S, Ruiz-Valdepeñas-Montiel V, Pedrero M, Fernández-Aceñero MJ, Barderas R, Pingarrón JM. Rapid endoglin determination in serum samples using an amperometric magneto-actuated disposable immunosensing platform. J Pharm Biomed Anal. 2016 Sep 10;129:288-293. doi: 10.1016/j.jpba.2016.07.020. Epub 2016 Jul 15. PMID: 27448312.</dc:identifier>
      <dc:identifier>0731-7085</dc:identifier>
      <dc:identifier>10.1016/j.jpba.2016.07.020</dc:identifier>
      <dc:identifier>https://hdl.handle.net/20.500.14352/95444</dc:identifier>
      <dc:identifier>https://doi.org/10.1016/j.jpba.2016.07.020</dc:identifier>