Person:
Martínez De La Casa Fernández-Borrella, José María

Loading...
Profile Picture
First Name
José María
Last Name
Martínez De La Casa Fernández-Borrella
Affiliation
Universidad Complutense de Madrid
Faculty / Institute
Óptica y Optometría
Department
Inmunología, Oftalmología y ORL
Area
Oftalmología
Identifiers
UCM identifierORCIDScopus Author IDWeb of Science ResearcherIDDialnet IDGoogle Scholar ID

Search Results

Now showing 1 - 10 of 44
  • Item
    Diagnostic ability of vessel density of the optic nerve head and macula versus structural parameters with optical coherence tomography in pseudoexfoliative glaucoma
    (Archivos de la Sociedad Española de Oftalmología (English Edition), 2023) Guemes Villahoz, Noemí; Burgos Blasco, B.; Morales-Fernández, L.; Perez García, P.; García Feijoo, Julián; Martínez De La Casa Fernández-Borrella, José María
    Purpose: To evaluate the diagnostic ability of the vessel density (VD) of the optic nerve head (ONH) and the macula on optical coherence tomography (OCT) angiography and the retinal nerve layer thickness (RNFL) thickness and the macular ganglion cell complex (GCC) thickness on OCT in patients with pseudoexfoliative glaucoma (PXG). Methods: Cross-sectional study including PXG patients and healthy controls. Demographic and clinical data were noted for all participants. Optical coherence tomography (OCT) and OCT angiography (OCTA) images of the ONH and macular area were obtained with the RS-3000 Advance OCT (Nidek Co., Gamagori, Japan). The RNFL and GCC thickness of different sectors was provided by the software. Macular VD of the superficial capillary plexus (SCP) and ONH VD of the radial peripapillary capillary plexus (RPCP) were registered. Groups were compared and area under the receiver operating characteristic (AUROC) curves were used to determine the power of discrimination of each parameter. Results: RNFL and GCC thickness and ONH and macular VD were significantly lower in PXG patients compared with healthy controls (all, p < 0.05). The best discrimination parameter was the average RNFL thickness (AUROC: 0.928). ONH VD AUROC was better than that of macular VD (AUROC: 0.897 and 0.780, respectively). ONH VD AUROC was comparable to RNFL thickness (p < 0.001). Conclusions: The diagnostic ability of ONH vessel density in PXG appears comparable to that of the structural parameters, RNFL and GCC thickness, obtained with OCT, and may be a valuable tool in clinical practice.
  • Item
    Additional Guidance on the Use of the PRESERFLO™ MicroShunt in the Treatment of Glaucoma: Insights from a Second Delphi Consensus Panel
    (Ophthalmology and Therapy, 2024) Khawaja, Anthony P.; Abegão Pinto, Luís; Stalmans, Ingeborg; Aptel, Florent; Barkander, Anna; Barton, Keith; Beckers, Henny; Iliev, Milko; Klink, Thomas; Marchini, Giorgio; Martínez De La Casa Fernández-Borrella, José María; Pillunat, Karin R; Simonsen, Jan H; Vass, Clemens
    Introduction: The PRESERFLO™ MicroShunt (PMS) has been proven to significantly lower intraocular pressure (IOP) in patients with glaucoma and has been available for use since 2019. With increasing published evidence and growing experience of glaucoma surgeons, the aim of this modified Delphi panel was to build on the findings of a previous Delphi panel conducted in 2021 and provide further guidance on the role of the PMS to treat patients with glaucoma in Europe. Methods: Thirteen European glaucoma surgeons experienced in the PMS procedure participated in a 3-round modified Delphi panel. A targeted literature review and expert steering committee guided Round 1 questionnaire development. Consensus was pre-defined at a threshold of ≥ 70% of panellists selecting 'strongly agree'/'agree' or 'strongly disagree'/'disagree' for 6-point Likert scale questions or ≥ 70% selecting the same option for multiple or single-choice questions. Questions not reaching consensus were restated/revised for the next round, following guidance from free-text responses/scoping questions. Results: In total, 28% (n = 9/32), 52% (n = 16/31) and 91% (n = 10/11) of statements reached consensus in Rounds 1, 2 and 3, respectively. There was agreement that the PMS may be used in patients with pigmentary, post-trauma or post-vitrectomy glaucoma and for patients with uveitic glaucoma without active inflammation. The PMS may be more suitable for patients with contact lenses than other subconjunctival filtering surgeries, without eliminating bleb-associated risks. Consensus was reached that combining PMS implantation and phacoemulsification may be as safe as standalone PMS surgery, but further efficacy data are required. Following a late rise in IOP ≥ 4 months post-surgery, topical aqueous suppressant drops or bleb revision may be suitable management options. Conclusions: This Delphi panel builds on the considerations explored in the 2021 Delphi panel and provides further detailed guidance for glaucoma surgeons on the use of the PMS, reflecting the availability of novel evidence and surgical experience. Videos are available for this article.
  • Item
    Corneal aberrations in primary congenital glaucoma and its visual correlation
    (International Ophthalmology, 2024) Ly-Yang, Fernando; Morales Fernández, Laura; García Bella, Javier; Garcia Caride, Sara; Santos Bueso, Enrique Miguel; Saenz Frances, Federico; Fernández-Vigo López, José; García Feijoo, Julián; Martínez De La Casa Fernández-Borrella, José María
    Primary congenital glaucoma (PCG) can cause permanent vision loss, and its prognosis is related to early detection and treatment. The main pathological defect consists of resistance to aqueous outflow through the trabecular meshwork due to abnormal development of tissue derived from the neural crest in the anterior chamber angle. Even after successful intraocular pressure (IOP) management in PCG poor visual outcomes still present a lifelong challenge. Vision loss in PCG is multifactorial, resulting from optic nerve damage, corneal scarring, and myopic astigmatism associated with anisometropic amblyopia. Although it is already known that children with PCG present with an altered corneal configuration, the knowledge of irregular astigmatism due to high-order aberrations (HOA) and due to the unequal expansion of the anterior segment, and its impact on visual outcomes, is not yet fully understood, to the best of our knowledge. Quality vision is influenced by the presence of aberrations in the eye's optical system, which can degrade the quality of the image projected onto the retina. Low-order aberrations (LOA), including myopia, hyperopia, and regular astigmatism, can be corrected by spectacles, while HOA cannot be corrected by ordinary means. Coma and spherical aberrations are the most visually significant HOAs, while trefoil and other HOAs have a lower impact on visual quality. The purpose of this article is to establish a quantitative correlation between HOA and visual acuity (VA) to measure the magnitude of the impact of the altered cornea on visual outcomes in PCG.
  • Item
    Diagnostic Ability of Macular Nerve Fiber Layer Thickness Using New Segmentation Software in Glaucoma Suspects
    (Investigative Ophthalmology & Visual Science, 2014) Martínez De La Casa Fernández-Borrella, José María; Cifuentes Canorea, Pilar; Berrozpe Villabona, Clara; Sastre Ibáñez, Marina; Polo Llorens, Vicente; Moreno Montañes, Javier; García Feijoo, Julián
    Purpose. To assess the capacity of internal retinal layer thickness measurements made at the macula using new spectral-domain optical coherence tomography (OCT) software to distinguish between healthy subjects and those with suspected glaucoma. The diagnostic performance of such measurements also was compared with that of conventional peripapillary retinal nerve fiber layer (RNFL) thickness measurements. Methods. The study included 38 subjects with suspected glaucoma and 38 age-matched healthy subjects. In one randomly selected eye of each participant, thickness measurements at the level of the macula were made of the nerve fiber layer (mRNFL), the ganglion cell layer (GCL), and the ganglion cell complex (GCC; GCL + internal plexiform layer) through automated OCT segmentation. Peripapillary RNFL thickness (pRNFL) also was determined using the conventional scan. Results. As the only variable showing intergroup variation, mRNFL in the glaucoma suspects was significantly thinner in the quadrants inner inferior (P = 0.003), inner temporal (P = 0.010), and outer inferior (P = 0.017). The variable best able to discriminate between the two groups was inner inferior mRNFL thickness, as indicated by an area below the receiver operating characteristic (ROC) curve of 0.742. Conclusions. Macular RNFL thickness measurements showed an improved diagnostic capacity over the other variables examined to distinguish between healthy subjects and glaucoma suspects.
  • Item
    A Diagnostic Calculator for Detecting Glaucoma on the Basis of Retinal Nerve Fiber Layer, Optic Disc, and Retinal Ganglion Cell Analysis by Optical Coherence Tomography
    (Investigative Ophthalmology & Visual Science, 2015) Larrosa Povés, José Manuel; Moreno Montañes, Javier; Martínez De La Casa Fernández-Borrella, José María; Polo Llorens, Vicente; Velázquez Villoria, Álvaro; Berrozpe Villabona, Clara; García Granero, Marta
    Purpose: The purpose of this study was to develop and validate a multivariate predictive model to detect glaucoma by using a combination of retinal nerve fiber layer (RNFL), retinal ganglion cell-inner plexiform (GCIPL), and optic disc parameters measured using spectral-domain optical coherence tomography (OCT). Methods: Five hundred eyes from 500 participants and 187 eyes of another 187 participants were included in the study and validation groups, respectively. Patients with glaucoma were classified in five groups based on visual field damage. Sensitivity and specificity of all glaucoma OCT parameters were analyzed. Receiver operating characteristic curves (ROC) and areas under the ROC (AUC) were compared. Three predictive multivariate models (quantitative, qualitative, and combined) that used a combination of the best OCT parameters were constructed. A diagnostic calculator was created using the combined multivariate model. Results: The best AUC parameters were: inferior RNFL, average RNFL, vertical cup/disc ratio, minimal GCIPL, and inferior-temporal GCIPL. Comparisons among the parameters did not show that the GCIPL parameters were better than those of the RNFL in early and advanced glaucoma. The highest AUC was in the combined predictive model (0.937; 95% confidence interval, 0.911–0.957) and was significantly (P = 0.0001) higher than the other isolated parameters considered in early and advanced glaucoma. The validation group displayed similar results to those of the study group. Conclusions: Best GCIPL, RNFL, and optic disc parameters showed a similar ability to detect glaucoma. The combined predictive formula improved the glaucoma detection compared to the best isolated parameters evaluated. The diagnostic calculator obtained good classification from participants in both the study and validation groups.
  • Item
    CPAMD8 loss-of-function underlies non-dominant congenital glaucoma with variable anterior segment dysgenesis and abnormal extracellular matrix
    (Human Genetics, 2020) Bonet Fernández, Juan Manuel; Aroca Aguilar, José Daniel; Corton Pérez, Marta; Ramírez Sebastián, Ana Isabel; Alexandre Moreno, Susana; García Antón, María Teresa; Salazar Corral, Juan José; Ferre Fernández, Jesús José; Atienzar Aroca, Raquel; Villaverde Montero, Cristina; Iancu, Ionut; Tamayo Durán, Alejandra; Méndez Hernández, Carmen Dora; Morales Fernández, Laura; Rojas López, Blanca; Ayuso García, Carmen; Coca Prados, Miguel; Martínez De La Casa Fernández-Borrella, José María; García Feijoo, Julián; Escribano, Julio
    Abnormal development of the ocular anterior segment may lead to a spectrum of clinical phenotypes ranging from primary congenital glaucoma (PCG) to variable anterior segment dysgenesis (ASD). The main objective of this study was to identify the genetic alterations underlying recessive congenital glaucoma with ASD (CG-ASD). Next-generation DNA sequencing identified rare biallelic CPAMD8 variants in four patients with CG-ASD and in one case with PCG. CPAMD8 is a gene of unknown function and recently associated with ASD. Bioinformatic and in vitro functional evaluation of the variants using quantitative reverse transcription PCR and minigene analysis supported a loss-of-function pathogenic mechanism. Optical and electron microscopy of the trabeculectomy specimen from one of the CG-ASD cases revealed an abnormal anterior chamber angle, with altered extracellular matrix, and apoptotic trabecular meshwork cells. The CPAMD8 protein was immunodetected in adult human ocular fluids and anterior segment tissues involved in glaucoma and ASD (i.e., aqueous humor, non-pigmented ciliary epithelium, and iris muscles), as well as in periocular mesenchyme-like cells of zebrafish embryos. CRISPR/Cas9 disruption of this gene in F0 zebrafish embryos (96 hpf) resulted in varying degrees of gross developmental abnormalities, including microphthalmia, pharyngeal maldevelopment, and pericardial and periocular edemas. Optical and electron microscopy examination of these embryos showed iridocorneal angle hypoplasia (characterized by altered iris stroma cells, reduced anterior chamber, and collagen disorganized corneal stroma extracellular matrix), recapitulating some patients’ features. Our data support the notion that CPAMD8 loss-of-function underlies a spectrum of recessive CG-ASD phenotypes associated with extracellular matrix disorganization and provide new insights into the normal and disease roles of this gene.
  • Item
    Comparision of intraocular pressure measured using the new icare 200™ rebound tonometer and the Perkins™ applanation tonometer in healthy subjects and in patients with primary congenital glaucoma
    (Archivos de la Sociedad Española de Oftalmología (English Edition), 2021) Pérez García, Pilar; Morales Fernández, Laura; Sáenz Francés, Federico; Méndez Hernández, Carmen Dora; García Feijoo, Julián; Santos Bueso, Enrique; Martínez De La Casa Fernández-Borrella, José María
    Objective: To compare intraocular pressure (IOP) measurements obtained using the Icare 200™ (IC200) rebound tonometer and the hand-held version of the Goldmann Applanation Tonometer (Perkins™ tonometer, GAT) in patients with primary congenital glaucoma (PCG) and in healthy subjects. Material and methods: A total of 42 eyes of healthy subjects (G1) and 40 patients with PCG (G2) were analysed. The following clinical data were collected: gender, age, Cup/Disc ratio, central corneal thickness (CCT). IOP was determined in the examination room using the IC200 and GAT tonometers, in the same order. Agreement between both tonometers was determined using the intraclass correlation coefficient (ICC) and Bland-Altman plot. A linear regression analysis was used to establish the IOP was affected by the studied variables. Results: Mean IOP between both tonometers (IC200 minus GAT) was: G1 = 15.91 (2.57) mmHg vs. 15.06 (2.12) mmHg (mean difference, MD = 0.84 (0.50) mmHg; P < .101) and G2=20.10 (6.37) vs.19.12 (5.62) (MD = 0.98 (1.36); P = 0.474). Excellent agreement was found between IC200 and GAT in both groups (ICC = G1: 0.875 (95% CI; 0.768−0.933; P < .001); G2: 0.924 (95% CI; 0.852−0.961; P < .001), and there was a statistically significant correlation between the IOP difference measured with IC200 and GAT and CCT in G1 (B=0.021; 95% CI; 0.005–0.037; P = .008), but was not statistically significant in G2. Conclusions: There was excellent agreement between the IC200 and GAT tonometers, both in healthy subjects and PCG, with a trend to overestimate IOP when measured with IC200. There was no influence by CCT on IOP measurements in patients with PGC.
  • Item
    PreserfloTM MicroShunt implantation combined with OlogenTM in primary and secondary glaucoma patients in a clinical setting
    (Indian Journal of Ophthalmology, 2023) Rojo Arnao, María; Martínez De La Casa Fernández-Borrella, José María; Albis Donado, Óscar; Yáñez Castro, Giovanni; Maroto Cejudo, Raquel; Téllez, Jesús; Menoyo Calatayud, Ricardo
    Purpose: This study aims to assess the effectiveness and safety of combining the Preserflo™ MicroShunt implant (MicroShunt) with a simultaneous Ologen™ implant in patients with glaucoma. Methods: We conducted a retrospective study on consecutive patients with medically uncontrolled glaucoma who underwent MicroShunt + Ologen implantation as a standalone procedure or in combination with phacoemulsification (combined procedure). Success was defined as achieving an intraocular pressure (IOP) of 6-15 mmHg at 18 months post surgery, with a preoperative IOP reduction of at least 20%, and without (complete success) or with (qualified success) the need for antiglaucoma medications. The primary endpoint was the success rate. Results: Forty-eight eyes from 47 patients were included, with 28 eyes (58.3%) undergoing the standalone procedure and 20 eyes (41.7%) undergoing the combined procedure. Overall, there was a significant reduction in preoperative IOP from 19.7 ± 5.8 mmHg to 11.4 ± 2.6 mmHg at 18 months (P < 0.0001). In the standalone procedure group, preoperative IOP decreased from 21.5 ± 5.2 mmHg to 11.7 ± 2.5 mmHg (P < 0.0001), and in the combined procedure group, preoperative IOP decreased from 17.1 ± 5.8 mmHg to 10.9 ± 2.7 mmHg (P = 0.0002), with no significant difference between the two groups regarding final IOP. The mean number of antiglaucoma medications significantly decreased from 3.2 ± 1.1 to 0.3 ± 0.7 in the overall study population (P < 0.0001). At 18 months, 40 eyes (83.3%) were classified as successful. Regarding safety, out of the total number of eyes, two (4.2%) experienced choroidal detachment without visual impairment, two (4.2%) had transient hyphema, one (2.1%) showed reactivation of a corneal herpetic ulcer, one (2.1%) had diplopia, and one (2.1%) exhibited a shallow anterior chamber during the first week. Conclusion: The combination of Ologen™ and Preserflo™ MicroShunt, either alone or in conjunction with phacoemulsification, demonstrated a favorable profile in terms of IOP reduction and safety.
  • Item
    Cambios refractivos post-keratomileusis láser in situ inducidos por hipertensión ocular aguda sin signos de ectasia corneal
    (Archivos de la Sociedad Española de Oftalmología, 2014) Martínez De La Casa Fernández-Borrella, José María; Rodríguez Uña, Ignacio; González Pastor, Elisa; Díaz Valle, David; García Feijoo, Julián
    Caso clínico: se presenta el caso de un varón de 34 años de edad, con pérdida progresiva de visión en el ojo izquierdo, que fue diagnosticado de glaucoma pigmentario con una presión intraocular de 32mmHg. Ocho años antes, el paciente había sido intervenido con cirugía refractiva (lasik). El tratamiento hipotensor condujo a cambios refractivos significativos acompañados de aplanamiento de la curvatura corneal. Discusión: proponemos que una elevada presión intraocular, actuando sobre una córnea previamente debilitada por la cirugía refractiva, puede producir alteraciones en la superficie corneal, induciendo cambios refractivos incluso en ausencia de ectasia corneal.
  • Item
    Scheie's line as a first sign of pigment dispersion syndrome
    (Archivos de la Sociedad Española de Oftalmología (English Edition), 2019) Santos Bueso, Enrique; García Sáenz, Sofía; Morales Fernández, Laura; Martínez De La Casa Fernández-Borrella, José María; Sáenz Francés, Federico
    A 50 year old woman was diagnosed with pigment dispersion syndrome (PDS) in the right eye and pigmentary glaucoma in the left eye in a routine medical examination. A line of pigment was observed in the vitreo-lenticular interface (Scheie's line) of the left eye and with an intraocular pressure of 26 mmHg. The Scheie's line (SL) develops by the accumulation of detached iris pigment in PDS and accumulated in the ligament of Wieger that forms the vitreo-lenticular union. The SL is considered a pathognomonic sign of PDS.