Person:
Diz Arias, Elena

Loading...
Profile Picture
First Name
Elena
Last Name
Diz Arias
Affiliation
Universidad Complutense de Madrid
Faculty / Institute
Óptica y Optometría
Department
Óptica
Area
Identifiers
UCM identifierORCIDScopus Author IDDialnet ID

Search Results

Now showing 1 - 5 of 5
  • Item
    Improving ocular surface comfort in contact lens wearers
    (Contact Lens and Anterior Eye, 2021) Fernández Jiménez, Elena; Diz Arias, Elena; Peral Cerda, María Asunción
    Purpose Contact lens discomfort (CLD) is a major concern that can lead to the decreased or abandoned use of contact lenses. Contact lens users with dry eye disease are more likely to present with CLD. This study was conducted to evaluate the efficacy of a bioprotective preservative free, hypotonic, 0.15% hyaluronic acid (HA)-3% Trehalose artificial tear in managing dry eye symptoms in contact lens wearers. Methods A prospective, single-arm, observational pilot study to evaluate the effectiveness of treatment with HA-Trehalose artificial tears in contact lens wearers (N = 33) aged 18–45 years with symptoms of ocular discomfort. Participants used a preservative-free, hypotonic HA-Trehalose artificial tear (1 drop/4 times per day) for 84 days. Participants were assessed using Visual Analogue Scale (VAS) for dry eye symptoms (pain, photophobia, dry eye sensation, blurry vision, foreign body sensation, itching, tingling/burning, and sticky eye feeling), Ocular Surface Disease Index (OSDI), Contact Lens Dry Eye questionnaire (CLDEQ-8), Berkley Dry Eye Flow-Chart (DEFC) on Day 0 and Day 84 and tear break-up time (TBUT), ocular surface staining with fluorescein and lissamine green, tear meniscus evaluation, and visual acuity on Day 0, 35, and 84. Results All VAS symptoms (except tingling/burning and sticky eye feeling), OSDI, CLEDQ-8, and DEFC showed statistically significant (p < 0.05) improvement from baseline (Day 0) to Day 84. Similarly, corneal (fluorescein) and conjunctival (lissamine green) quality improved during the study (p < 0.05 at Day 84 versus baseline). Tear break-up time (TBUT), conjunctival (lissamine green) staining, and tear meniscus decreased but the changes were not statistically significant. Visual acuity did not change during the study. There were no ocular or systemic adverse events. Conclusions This study showed that the instillation of a preservative-free, hypotonic, HA-Trehalose artificial tear in contact lenses wearers with dry eye syndrome significantly improved symptoms and reduced associated signs such as corneal and conjunctival staining.
  • Item
    Variation of Meibomian glands contrats throughout the day
    (2024) Peral Cerda, María Asunción; Fernandez Jimenez Elena; Diz Arias, Elena; Gómez Pedrero, José Antonio; Peral Cerda, María Asunción; Gómez Pedrero, José Antonio; Peral A
    Purpose: To evaluate Meibomian glands (MG), specialized imaging techniques are used. The most commonly used technique for the observation of MG is non-contact meibography with infrared light. This technique allows to see specific details of the MG, provides quantitative measurements, in addition to structural appearance, shortening, distortions or atrophy. [1] Recent studies have shown that the analysis of MG contrasts can represent an advance in the diagnosis of related pathologies to MG, such as Meibomian gland dysfunction and Blepharitis. [2] The present study wants to observe the contrast variation throughout the day in the spaces between two adjacent MG, interglandular contrasts (CINTER) and within the same gland, intraglandular contrasts (CIN). The main objective of this study is to observe the variation of MG contrasts throughout the day and analyze its possible correlation with alterations related to these glands. Methods: A prospective, descriptive, pilot study was carried out on 8 participants, including controls, MG pathology participants, and contact lens users. A set of tests were performed, including symptomatology tests, clinical tests to recognize the ocular surface and an assessment of the MG. Images of the MG were taken throughout the day, with the Oculus Keratograph 5MTM. Meibography images were captured from 8 am to 8 pm in two hours slots. The eyelids were everted and the images were always captured by the same clinical examiner. The meibography images have been processed with the Matlab® program to analyze the CINTER and CIN contrast. [3] Results: Preliminary results show that there is an oscillatory and fluctuating trend in glandular contrasts throughout the day, following different patterns in each subject. Conclusions: As has been previously studied, MG contrasts are postulated as a possible biomarker of MG alterations. The study of the behavior of these contrasts throughout the day and in different groups of subjects may lead to advances in the diagnosis of MG alterations or pathologies such as Meibomian gland dysfunction or Blepharitis, and could also provide further insight on the meibum production cycle and MG physiology.
  • Item
    PhDAY 2020 -FOO (Facultad de Óptica y Optometría)
    (2020) Pintor Just, Jesús Jerónimo; Carpena Torres, Carlos; Peral Cerda, María Asunción; Pérez de Lara, María Jesús; Toral, Fernando; Crooke Álvarez, Almudena; Pastrana Robles, Cristina; Carracedo Rodríguez, Juan Gonzalo; Cayuela López, Ana; Sorzano Sánchez, Óscar; Charbel, Carla; Garzón Jiménez, Nuria; Carballo Álvarez, Jesús; Diz Arias, Elena; Fernández Jiménez, Elena; Lledó Mayans, Victoria Eugenia; Gómez Pedrero, José Antonio; Durán Prieto, Elena; López Alonso, José Manuel; Fernández Torres, Miguel Ángel; Guzmán Aránguez, Ana Isabel; Gómez Manzanares, Ángela; Vázquez Molini, Daniel; Martínez Antón, Juan Carlos; Bernárdez Vilaboa, Ricardo; Mayorga Pinilla, Santiago; Álvarez Fernández-Balbuena, Antonio; Benítez, AntoJ.; Igalla El-Youssfi, Asmae; León Álvarez, Alejandro; Palomo Álvarez, Catalina; Awad Alkozi, Hanan; Sánchez Naves, Juan; Martínez Alberquilla, Irene; García Montero, María; Ruiz Alcocer, Javier; Madrid Costa, David; Martínez Florentín, Gema; Papas, Eric B.; Medrano Muñoz, Sandra Milena; Molina, Nancy; Jurado, Sandra; Oliveiros López, Juan; Platero Alvarado, Nadiuska Cristine; Garrido Mercado, Rafaela; Pérez Garmendia, Carlos; Antona Peñalba, Beatriz; Barrio De Santos, Ana Rosa; González Pérez, Mariano; Pérez Garmendia, Carlos; Serramito Blanco, María; Privado Aroco, Ana; Almalki, Wael; Bodas Romero, Julia; Ouzzani, Mohamed; Paune, Jaume; Calderón García, Raquel; Pitarch Velasco, Aída; Cebrián, José Luis; Sánchez Pérez, María Isabel; García Rojo, Marta María; Bonnin Arias, Cristina Natalia; Sánchez Ramos, Celia; Gutiérrez Jorrín, Sara Carmen; Rodríguez Alonso, Xabier; Laucirica Sáenz, Gorka; Arranz Márquez, Esther; Alonso Castellanos, Miriam; Teus Guezala, Miguel Ángel; Hernández Verdejo, José Luis; Mármol Errasti, Esther; Martín García, Beatriz; Arriola Villalobos, Pedro; Gómez De Liaño Sánchez, María Rosario; Mínguez Caro, N; Orduña Azcona, Javier; Navarro Gil, Francisco Javier; Huete Toral, Fernando; Rodríguez Pomar, Candela; Martínez Águila, Alejandro; Martín Gil, Alba; Tomé de la Torre, Miguel Ángel
    Por cuarto año consecutivo los doctorandos de la Facultad de Óptica y Optometría de la Universidad Complutense de Madrid cuentan con un congreso propio organizado por y para ellos, el 4º PhDAY- FOO. Se trata de un congreso gratuito abierto en la que estos jóvenes científicos podrán presentar sus investigaciones al resto de sus compañeros predoctorales y a toda la comunidad universitaria que quiera disfrutar de este evento. Apunta en tu agenda: el 15 de octubre de 2020. En esta ocasión será un Congreso On-line para evitar que la incertidumbre asociada a la pandemia Covid-19 pudiera condicionar su celebración.
  • Item
    A Comparative Study of Two Imaging Techniques of Meibomian Glands
    (Life, 2023) Diz Arias, Elena; Fernández Jiménez, Elena; Peral Cerda, María Asunción; Gómez Pedrero, José Antonio
    In the present study, two different meibographers, Oculus Keratograph 5M (K5M) that uses 840 nm infrared light and the Visible Light Non-Contact Meibographer (VLNCM) that uses 610 nm visible light have been used to obtain meibography images from normal and Meibomian Gland Dysfunction (MGD) population. The main objective has been to validate and demonstrate that the use of visible light is useful for observation and quantification of MG in clinical practice. Twenty participants were enrolled in this prospective study. The upper eyelids of one randomly chosen eye were used to obtain results. Forty images were captured and analysed. Three specialized observers were recruited to grade images using Pult and Riede Pult 5-degree scale, in two different sessions. Intra-observer agreement between sessions for both devices was shown. Inter-observer variability analysis showed discrepancy between meiboscores obtained from observers with K5M (p-value < 0.05), except for session 2 in the pathology group, while no statistical difference was found with VLNCM. Repeatability analysis found no statistically significant differences between sessions. Correlation between meibographers showed no statistically significant difference and a moderate correlation coefficient between meiboscores graded with the two devices. The current study suggests that VLNCM can allow MG to be properly visualized and classified in the upper eyelids.
  • Item
    Role of instrumental factors in Meibomian gland contrast assessment
    (Ophthalmic and Physiological Optics, 2023) Diz Arias, Elena; Fernández Jiménez, Elena; Peral Cerda, María Asunción; Gómez Pedrero, José Antonio
    Purpose: Meibomian gland contrast has been suggested as a potential biomarker in Meibomian gland dysfunction. This study analysed the instrumental factors related to contrast. The objectives were to determine whether the mathematical equations used to compute gland contrast (e.g., Michelson or Yeh and Lin), impact the ability to identify abnormal individuals, to ascertain whether contrast between the gland and the background could be an effective biomarker and to assess whether using contrast-enhancement on the gland image improves its diagnostic efficacy. Methods: A total of 240 meibography images from 40 participants (20 controls and 20 having Meibomian gland dysfunction or blepharitis), were included. The Oculus Keratograph 5M was used to capture images from the upper and lower eyelids of each eye. The contrast of unprocessed images and those pre-processed with contrast-enhancement algorithms were analysed. Contrast was measured on the eight central glands. Two equations for contrast computation were used, and the contrast both between glands and within a gland were calculated. Results: Significant differences were found between the groups for inter-gland area in the upper (p = 0.01) and lower eyelids (p = 0.001) for contrast measured with the Michelson formula. Similar effects were observed when using the Yeh and Lin method in the upper (p = 0.01) and lower eyelids (p = 0.04). These results were obtained for images enhanced with the Keratograph 5M algorithm. Conclusions: Meibomian gland contrast is a useful biomarker of disease related to the Meibomian glands. Contrast measurement should be determined using contrast-enhanced images in the inter-gland area. However, the method used to compute contrast did not influence the results.