Person:
Sánchez Ramos, Celia

Loading...
Profile Picture
First Name
Celia
Last Name
Sánchez Ramos
Affiliation
Universidad Complutense de Madrid
Faculty / Institute
Óptica y Optometría
Department
Optometría y Visión
Area
Optica
Identifiers
UCM identifierScopus Author IDDialnet IDGoogle Scholar ID

Search Results

Now showing 1 - 10 of 61
  • Item
    Acid-sensing ion channels (ASICs) 2 and 4.2 are expressed in the retina of the adult zebrafish
    (Cell and Tissue Research, 2015) Viña Fernández, Eliseo; Parisi, Valentina; Sánchez Ramos, Celia; Cabo, Roberto; Guerrera, María Cristina; Quirós, Luis Manuel; Germaná, Antonio M.; Vega, José Antonio; García Suárez, Olivia
    Acid-sensing ion channels (ASICs) are H+-gated, voltage-insensitive cation channels involved in synaptic transmission, mechanosensation and nociception. Different ASICs have been detected in the retina of mammals but it is not known whether they are expressed in adult zebrafish, a commonly used animal model to study the retina in both normal and pathological conditions. We study the expression and distribution of ASIC2 and ASIC4 in the retina of adult zebrafish and its regulation by light using PCR, in situ hybridization, western blot and immunohistochemistry. We detected mRNA encoding zASIC2 and zASIC4.2 but not zASIC4.1. ASIC2, at the mRNA or protein level, was detected in the outer nuclear layer, the outer plexiform layer, the inner plexiform layer, the retinal ganglion cell layer and the optic nerve. ASIC4 was expressed in the photoreceptors layer and to a lesser extent in the retinal ganglion cell layer. Furthermore, the expression of both ASIC2 and ASIC4.2 was down-regulated by light and darkness. These results are the first demonstration that ASIC2 and ASIC4 are expressed in the adult zebrafish retina and suggest that zebrafish could be used as a model organism for studying retinal pathologies involving ASICs.
  • Item
    Elemento bloqueante de longitudes de onda corta en fuentes de iluminación de tipo LED
    (2015) Sánchez Ramos, Celia; Universidad Complutense de Madrid
    Método, producto y elemento bloqueante de longitudes de onda corta en fuentes de iluminación de tipo LED que consiste en un sustrato con un pigmento distribuido de manera uniforme en su superficie y, porque dicho pigmento tiene una densidad óptica tal que permite la absorción selectiva de longitudes de onda corta comprendidas entre 380 nm y 500 nm en un rango comprendido entre el 1 y el 99%.
  • Item
    Método y aparato para el reconocimiento biométrico corneal
    (2019) Sánchez Ramos, Celia; Bonnin Arias, Cristina Natalia; Pascau González-Garzón, Javier; Moreta Martínez, Rafael; Universidad Complutense de Madrid, Universidad Carlos III de Madrid
    Método de reconocimiento biométrico corneal que comprende: (i) capturar al menos una imagen de las superficies corneales; y (ii) cuantificar las irregularidades topográficas de dichas superficies corneales para obtener parámetros característicos y diferenciales de la topografía corneal para al menos un sujeto; y donde cada captura se configura como un registro con al menos un parámetro ocular; y que comprende una etapa de comparar: al menos un primer registro con al menos un parámetro ocular; y al menos un segundo registro del mismo parámetro ocular; y donde además comprende una etapa de clasificación de los datos resultantes de la comparación mediante un algoritmo de clasificación con auto-aprendizaje.
  • Item
    Technical Report: Potential risks to human health of Light Emitting Diodes (LEDs) (European Commission)
    (2018) Ana Proykova; Theodoros Samaras; Rodica-Mariana Ion; Ellen M Bruzell; Jean-François Doré; Massimo Nicolo; John O'Hagan; Sánchez Ramos, Celia; Linda van Kerkhof
    Following a request from the European Commission, the Scientific Committee on Health, Environmental and Emerging Risks (SCHEER) reviewed recent evidence to assess potential risks to human health posed by Light Emitting Diodes (LEDs) emissions. The review of the published research conducted by the SCHEER has led to valuable conclusions and identified certain gaps in knowledge on potential risks to human health from LEDs. The Committee concluded that there is no evidence of direct adverse health effects from LEDs emission in normal use (lamps and displays) by the general healthy population. There is some evidence that exposure to light in the late evening, including that from LED lighting and/or screens, may have an impact on the circadian rhythm. At the moment, it is not yet clear if this disturbance of the circadian system leads to adverse health effects. Vulnerable and susceptible populations (young children, adolescents and elderly people) have been considered separately. Children have a higher sensitivity to blue light and although emissions may not be harmful, blue LEDs (between 400 nm and 500 nm) including those in toys may be very dazzling and may induce photochemical retinopathy, which is a concern especially for children below three years of age. Older people may experience discomfort from exposure to light that is rich in blue light. Although there are cellular and animal studies showing adverse effects raising concerns, particularly in susceptible populations, their conclusions derive from results obtained either using exposure conditions that are difficult to relate to human exposures or using exposure levels greater than those likely to be achieved with LED lighting systems in practice. Some LEDs present potential health concerns due to temporal light modulation (flicker) at frequencies of 100 Hz and above. Reliable information on the dose-response relationship for adverse health effects for the healthy general public is not available in the scientific literature for all wavelengths emitted by LED devices. Since the use of LED technology is still evolving, the Committee considers that it is important to closely monitor the risk of adverse health effects from long-term LED use by the general population.
  • Item
    Dioptrio bloqueante de radiaciones de longitudes de onda corta y media del espectro visible que afecta a la fisiología humana
    (2017) Sánchez Ramos, Celia; García Manchado, Nilo; Universidad Complutense de Madrid / Tecnología Sostenible y Responsable SL
    Dioptrio bloqueante de radiaciones de longitudes onda corta y media del espectro visible que afectan la fisiología humana que comprende la absorción selectiva de longitudes de onda corta comprendidas entre 380 nm y 500 nm entre un umbral máximo y un umbral mínimo de absorción; y la absorción selectiva de longitudes de onda media comprendida entre 500 nm y 590 nm entre un umbral máximo y un umbral mínimo de absorción; y donde la absorción selectiva de longitudes de onda corta y media comprendidas entre los 380-590 nm no bloquea totalmente el paso de luz visible en dicho rango. Otras realizaciones incluyen una pantalla LED, un producto de programa informático y un dispositivo electrónicoy lentes, oftálmicas, intraoculares u solares.
  • Item
    Dispositivo y Método simulador de entornos para la evaluación de la función visual
    (2018) Sánchez Ramos, Celia; Bonnin Arias, Cristina Natalia; Universidad Complutense de Madrid
    Dispositivo y método simulador de entornos de evaluación de la función visual que comprende un soporte que aloja un luxómetro medidor de la iluminación ambiente que comprende una pluralidad de dioptrios de densidad óptica neutra (DO); y donde la relación entre la densidad óptica y la transmitancia (T) del dioptrio viene dada por DO=log(1/T); y donde los dioptrios de densidad óptica neutra (DO) están dispuestos en el soporte en correspondencia con el sistema visual de un individuo y configurados para alcanzar distintos niveles de iluminación directamente en el sistema visual del individuo sin realizar una variación real de la iluminación ambiente.
  • Item
    Removal of the blue component of light significantly decreases retinal damage after high intensity exposure
    (PLoS ONE, 2018) Vicente-Tejedor, Javier; Marchena, Miguel; Ramírez, Laura; García Ayuso, Diego; Gómez Vicente, Violeta; Sánchez Ramos, Celia; Villa Polo, Pedro de la; Germain, Francisco
    Light causes damage to the retina (phototoxicity) and decreases photoreceptor responses to light. The most harmful component of visible light is the blue wavelength (400–500 nm). Different filters have been tested, but so far all of them allow passing a lot of this wavelength (70%). The aim of this work has been to prove that a filter that removes 94% of the blue component may protect the function and morphology of the retina significantly. Three experimental groups were designed. The first group was unexposed to light, the second one was exposed and the third one was exposed and protected by a blue-blocking filter. Light damage was induced in young albino mice (p30) by exposing them to white light of high intensity (5,000 lux) continuously for 7 days. Short wavelength light filters were used for light protection. The blue component was removed (94%) from the light source by our filter. Electroretinographical recordings were performed before and after light damage. Changes in retinal structure were studied using immunohistochemistry, and TUNEL labeling. Also, cells in the outer nuclear layer were counted and compared among the three different groups. Functional visual responses were significantly more conserved in protected animals (with the blue-blocking filter) than in unprotected animals. Also, retinal structure was better kept and photoreceptor survival was greater in protected animals, these differences were significant in central areas of the retina. Still, functional and morphological responses were significantly lower in protected than in unexposed groups. In conclusion, this blue-blocking filter decreases significantly photoreceptor damage after exposure to high intensity light. Actually, our eyes are exposed for a very long time to high levels of blue light (screens, artificial light LED, neons…). The potential damage caused by blue light can be palliated.
  • Item
    New Optical Filter Plate for Use as Eye Protection by Welders
    (Welding journal, 2013) Langa Moraga, Antonio; Bonnin Arias, Cristina Natalia; Chamorro, Eva; Pérez Carrasco, María Jesús; Sánchez Ramos, Celia
    People whose work tasks involve the use of welding torches are at special risk of suffering eye injuries due to the emission of visible, short-wavelength radiation. Current legislation requires that a company provide its employees with protection against the harmful radiation produced by welding equipment. Often, however, a worker will be reluctant to use protective goggles since these markedly cut visibility and can consequently lead to errors or even burns. This practice of avoiding the use of protection makes them susceptible to suffer irreversible severe retinal damage leading to partial or complete loss of vision. In this paper, we propose the use of a new photoprotective filter in the form of safety goggles that seeks to improve the compromised vision produced by conventional filters. We compare a series of visual function variables in 36 adults, aged 30 to 58 years, using the new optical filter and a conventional filter used for welding protection. Our findings suggest that the filter proposed provides optimal protection against the harmful effects of short-wavelength radiation while minimizing the reduced vision effects of conventional filters used for this purpose.
  • Item
    Pupilometría dinámica mesópica: valores patrón y su variación con el efecto del alcohol
    (2015) Lobato Rincón, Luis-Lucio; Sánchez Ramos, Celia; Murciano Cespedosa, Antonio
    El reflejo pupilar a la luz puede ser usado como un indicador ocular no invasivo de la integridad del sistema nervioso autónomo cefálico. En este sentido, la sensibilidad espectral de la respuesta pupilar en condiciones mesópicas es un elemento novedoso que no se ha estudiado convenientemente hasta ahora en relación a la edad. Asimismo, la literatura es escasa en lo concerniente a la relación que existe entre el diámetro pupilar basal y el consumo gradual de alcohol. La presente tesis doctoral consta de dos experimentos. Por un lado, investiga, en una muestra amplia, los efectos de los factores edad (grupo 45 años frente a grupo mayor de 45 años) y longitud de onda (luz monocromática roja de 600 nm, verde de 510 nm y azul de 450 nm, además de luz blanca de 5600gradosK), sobre tres variables del reflejo pupilar a la luz: latencia de respuesta, amplitud de constricción y velocidad media de constricción. Por otro lado, en una muestra de adultos jóvenes, se aborda la relación entre posible el efecto del consumo de alcohol sobre el diámetro pupilar en condiciones mesópicas. En la estadística del primer estudio se utilizan, en un primer lugar, Modelos Lineares Generalizados y, en la medida que los resultados de la interacción entre factores sugieren análisis posteriores, se desarrolla un Diseño en Bloques Completamente Aleatorizados para estudiar por separado el efecto de la luz; y una comparación t de Student y Análisis de la Covarianza para estudiar el efecto de la edad. Para todos los sujetos, la respuesta pupilar a la luz tuvo la mayor amplitud y menor latencia en las condiciones de luz blanca y 510 nm respectivamente. En relación con la edad, los sujetos mayores de 45 años exhibieron un incremento de la latencia en luz blanca y un declive de la velocidad a luz de 510 nm comparados con los sujetos de menor edad. En el segundo experimento, el test estadístico utilizado es la relación lineal simple entre incremento de diámetro pupilar basal y concentración de alcohol en aire espirado, confirmándose dicha relación de forma significativa, de tal manera que a cada unidad que aumenta la alcoholemia, le corresponde una estimación de un aumento del valor medio de 1,14 unidades de diámetro basal. Finalmente, se destacan posibles las implicaciones de los hallazgos, como la posibilidad de complementar la evaluación de la integridad del sistema nervioso cefálico con métodos pupilométricos.
  • Item
    Reliability of retinal imaging screening in retinopathy of prematurity
    (Anales de Pediatría, 2014) Navarro Blanco, Carolina; Peralta Calvo, Jesús M.; Pastora Salvador, Natalia; Álvarez Rementería, Laureano; Chamorro Gutiérrez, Eva; Sánchez Ramos, Celia
    Introducción: La retinopatía del prematuro (ROP) es una causa potencialmente evitable de ceguera en niños. Los avances en la atención neonatal posibilitan la supervivencia de bebés extremadamente prematuros, que presentan una mayor incidencia de la enfermedad. El objetivo del estudio es evaluar la fiabilidad del cribado de ROP mediante retinografía con la cámara gran angular RetCam 3 y también estudiar la variabilidad del diagnóstico de ROP según el evaluador. Material y métodos: El examen de oftalmoscopia indirecta fue realizado por un Oftalmólogo Pediátrico Experto en ROP. El mismo oftalmólogo y un técnico especializado en captura de imágenes digitales tomaron imágenes de retina utilizando la cámara gran angular RetCam 3. Un total de 30 conjuntos de imágenes fueron analizados por 3 grupos enmascarados: grupo A (8 oftalmólogos), grupo B (5 expertos en visión) y grupo C (2 oftalmólogos expertos en ROP). Resultados: Según el diagnóstico mediante oftalmoscopia indirecta, la sensibilidad (26-93), Kappa (0,24-0,80) y el porcentaje de concordancia fueron estadísticamente significativos en el grupo C para el diagnóstico de ROP Tipo 1. En el diagnóstico de ROP Tipo 1 +Tipo 2, Kappa (0,17-0,33) y el porcentaje de acuerdo (58-90) fueron estadísticamente significativos, con valores superiores en el grupo C. Conclusión: El diagnóstico realizado por oftalmólogos expertos en ROP con la cámara gran angular RetCam 3 ha demostrado ser un método fiable.