Person:
Pedrero Muñoz, María

Loading...
Profile Picture
First Name
María
Last Name
Pedrero Muñoz
Affiliation
Universidad Complutense de Madrid
Faculty / Institute
Ciencias Químicas
Department
Química Analítica
Area
Química Analítica
Identifiers
UCM identifierORCIDScopus Author IDWeb of Science ResearcherIDDialnet IDGoogle Scholar ID

Search Results

Now showing 1 - 10 of 11
  • Item
    Amperometric Immunosensing Scaffolds for Rapid, Simple, Non-Invasive and Accurate Determination of Protein Biomarkers of Well-Accepted and Emerging Clinical Importance
    (Proceedings, 2017) Pedrero Muñoz, María; Muñoz San Martín, Cristina; Torrente Rodríguez, Rebeca Magnolia; Ruiz Valdepeñas Montiel, Víctor; Vargas Orgaz, Eva; Manuel de Villena Rueda, Francisco Javier; Barderas Manchado, Rodrigo; Campuzano Ruiz, Susana; Pingarrón Carrazón, José Manuel
  • Item
    Magnetic Beads-Based Sensor with Tailored Sensitivity for Rapid and Single-Step Amperometric Determination of miRNAs
    (International Journal of Molecular Sciences, 2017) Vargas Orgaz, Eva; Torrente Rodríguez, Rebeca Magnolia; Ruiz Valdepeñas Montiel, Víctor; Povedano Muñumel, Eloy; Pedrero Muñoz, María; Montoya, Juan; Campuzano Ruiz, Susana; Pingarrón Carrazón, José Manuel
    This work describes a sensitive amperometric magneto-biosensor for single-step and rapid determination of microRNAs (miRNAs). The developed strategy involves the use of direct hybridization of the target miRNA (miRNA-21) with a specific biotinylated DNA probe immobilized on streptavidin-modified magnetic beads (MBs), and labeling of the resulting heteroduplexes with a specific DNA–RNA antibody and the bacterial protein A (ProtA) conjugated with an horseradish peroxidase (HRP) homopolymer (Poly-HRP40) as an enzymatic label for signal amplification. Amperometric detection is performed upon magnetic capture of the modified MBs onto the working electrode surface of disposable screen-printed carbon electrodes (SPCEs) using the H2O2/hydroquinone (HQ) system. The magnitude of the cathodic signal obtained at −0.20 V (vs. the Ag pseudo-reference electrode) demonstrated linear dependence with the concentration of the synthetic target miRNA over the 1.0 to 100 pM range. The method provided a detection limit (LOD) of 10 attomoles (in a 25 μL sample) without any target miRNA amplification in just 30 min (once the DNA capture probe-MBs were prepared). This approach shows improved sensitivity compared with that of biosensors constructed with the same anti-DNA–RNA Ab as capture instead of a detector antibody and further labeling with a Strep-HRP conjugate instead of the Poly-HRP40 homopolymer. The developed strategy involves a single step working protocol, as well as the possibility to tailor the sensitivity by enlarging the length of the DNA/miRNA heteroduplexes using additional probes and/or performing the labelling with ProtA conjugated with homopolymers prepared with different numbers of HRP molecules. The practical usefulness was demonstrated by determination of the endogenous levels of the mature target miRNA in 250 ng raw total RNA (RNAt) extracted from human mammary epithelial normal (MCF-10A) and cancer (MCF-7) cells and tumor tissues.
  • Item
    Project number: 316
    Implementación de la metodología flipped classroom en los laboratorios de Química Analítica
    (2023) Reviejo García, Ángel Julio; Agüí Chicharro, María Lourdes; Campuzano Ruiz, Susana; Gamella Carballo, Maria; García Martín, Ángel Felipe; González Cortés, Araceli; Guerrero Blanco, José Ignacio; Mateos Briz, María Raquel; Miguel Bravo, María; Pérez Ginés, Víctor; Reviejo Martínez, Eva; Romano Martín, Santiago; Ruiz-Valdepeñas Montiel, Víctor; Sánchez Tirado, Esther; Santiago Sáez, Andrés Sebastián; Serafín González-Carrato, Verónica; Torrente Rodríguez, Rebeca Magnolia; Yáñez-Sedeño, Paloma; Pedrero Muñoz, María
    Adaptar el sistema tradicional de aprendizaje a las necesidades actuales del alumnado empleando la metodología flipped classroom en el laboratorio de Química Analítica I, con el objetivo de fomentar el aprendizaje utilizando herramientas digitales.
  • Item
    Electrochemical immunoplatform to help managing pancreatic cancer
    (Journal of Electroanalytical Chemistry, 2023) Pérez Ginés, Víctor; Torrente Rodríguez, Rebeca Magnolia; Pedrero Muñoz, María; Martínez-Bosch, Neus; García de Frutos, Pablo; Navarro, Pilar; Pingarrón Carrazón, José Manuel; Campuzano Ruiz, Susana
    Pancreatic ductal adenocarcinoma (PDAC) is the solid tumor with the worst prognosis, representing today the third cause of cancer-related deaths in developed countries and expected to be the second in 2030. Today, CA19-9 remains the only clinically used marker for management of PDAC (FDA-approved as a disease moni- toring marker). This work reports a disposable amperometric immunoplatform for the determination of CA19-9. The immunoplatform skilfully combines the advantages of magnetic microsupports (MBs) for implementation of the immunoassay and amperometric transduction on screen-printed carbon electrodes (SPCEs). The method involves the preparation of sándwich immunocomplexes enzymatically labeled with the enzyme horseradish peroxidase (HRP) on the MBs and uses a detection antibody conjugated to HRP. Once the HRP- labeled sandwich immunocomplexes-bearing MBs were trapped on the SPCE surface, the variation of the catho- dic current was measured in the presence of H2O2 and hydroquinone (HQ), which was directly proportional to the concentration of CA19-9. Under the optimized experimental conditions, the immunoplatform allowed the amperometric determination of CA19-9 standards over the 5.0 to 500 U mL−1 concentration range, with a limit of detection (LOD) value of 1.5 U mL−1 in 1 h. The method exhibits good reproducibility and selectivity and the magnetic immunoconjugates shows a good storage stability. The immunoplatform was applied to the deter- mination of CA19-9 in serum samples of a medium-sized cohort (22 individuals) of healthy subjects and patients diagnosed with PDAC. The obtained results demonstrated the immunoplatform ability to discriminateboth types of individuals within 1 h after sample dilution. The developed immunoplatform represents an improvement in terms of cost, applicability and accessibility compared to the ELISA-based techniques currently used in the clinic.
  • Item
    Affinity-Based Wearable Electrochemical Biosensors: Natural versus Biomimetic Receptors
    (Analysis and Sensing, 2022) Campuzano Ruiz, Susana; Pedrero Muñoz, María; Torrente Rodríguez, Rebeca Magnolia; Pingarrón Carrazón, José Manuel
    This review delves into the titanic research efforts carried out during the last years on affinity-based wearable electrochemical biosensors, using both natural (antibodies) and biomimetic (aptamers, peptides and molecular imprinted polymers) receptors. The rationale and application of selected representative strategies is critically discussed, ending with realistic and futuristic visions of the technical barriers, challenges and prospects in the development and adoption of these biodevices in daily routines to ensure well-being against known, unknown and unexpected threats.
  • Item
    Project number: PIMCD320/23-24
    Contribuyendo a la internacionalización de la docencia práctica inclusiva y sostenible en Química Analítica
    (0024) Gamella Carballo, María; Pedrero Muñoz, María; Campuzano Ruiz, Susana; Serafín González-Carrato, Verónica; Torrente Rodríguez, Rebeca Magnolia; Ruiz Valdepeñas Montiel, Víctor; Valverde De La Fuente, Alejandro; Povedano Muñumel, Eloy; Muñoz San Martín, Cristina; Pérez Ginés, Víctor; Blázquez García, Marina; Tejerina Miranda, Sandra; de Valle Ávila, Marcos; Molla Escudero, David
  • Item
    Multiplexed magnetic beads-assisted amperometric bioplatforms for global detection of methylations in nucleic acids
    (Analytica Chimica Acta, 2021) Povedano Muñumel, Eloy; Gamella Carballo, María; Torrente Rodríguez, Rebeca Magnolia; Ruiz Valdepeñas Montiel, Víctor; Montero-Calle, Ana; Solís-Fernández, Guillermo; Navarro Villoslada, Fernando; Pedrero, María; Peláez-García, Alberto; Mendiola, Marta; Hardisson, David; Feliú, Jaime; Barderas, Rodrigo; Pedrero Muñoz, María; Pingarrón Carrazón, José Manuel
    This work reports the first electrochemical bioplatform developed for the multidetection of 5-methylcytosine (5-mC) and 5-hydroxymethylcytosine (5-hmC) in DNA, DNA N6-methyladenine (6mA) and RNA N6-methyladenosine (m6A) methylations at global level. Direct competitive immunoassays were implemented on the surface of magnetic beads (MBs) and optimized for the single amperometric determination of different targets varying in length, sequence and number of methylations on screenprinted carbon electrodes. After evaluating the sensitivity and selectivity of such determinations and the confirmation of no cross-reactivity, a multiplexed disposable platform allowing the simultaneous determination of the mentioned four methylation events in only 45 min has been prepared. The multiplexed bioplatform was successfully applied to the determination of m6A in cellular total RNA and of 5-mC, 5-hmC and 6mA in genomic DNA extracted from tissues. The developed bioplatform showed its usefulness to discriminate the aggressiveness of cancerous cells and between healthy and tumor tissues of colorectal cancer patients.
  • Item
    Amperometric magnetoimmunoassay for the determination of lipoprotein(a)
    (Microchimica Acta, 2015) Kaçar, Ceren; Torrente Rodríguez, Rebeca Magnolia; Pedrero Muñoz, María; Campuzano Ruiz, Susana; Kilic, Esma; Pingarrón Carrazón, José Manuel
    A highly sensitive amperometric magnetoimmunoassay for rapid determination of lipoprotein(a) (Lp(a)), an important predictor of cardiovascular disease risk, in human serum, is described. It uses a sandwich configuration involving selective capture antibody [antiLp(a)] and biotinylated detector antibody [biotinantiLp(a)], and a streptavidin-HRP conjugate on carboxymodified magnetic beads (HOOC-MBs). The resulting MBs bearing the sandwiched immunoconjugates were captured by a magnet placed under the working electrode surface of a disposable screen-printed carbon electrode and the extent of the affinity reaction was monitored amperometrically at −0.20 V (vs a silver pseudo-reference electrode) in the presence of hydroquinone as an electron transfer mediator and upon addition of H2O2 as the enzyme substrate. The method exhibited a wide linear response range (from 0.01 to 0.5 μgmL−1), a detection limit of 4 ng mL−1, and an excellent selectivity over other serum components. The utility of the immunoassay was demonstrated by analyzing a reference serum containing a certified quantity of Lp(a). The performance of this magnetoimmunoassay compares favorably to that of an integrated amperometric immunoassay described earlier.
  • Item
    Comparison of Different Strategies for the Development of Highly Sensitive Electrochemical Nucleic Acid Biosensors Using Neither Nanomaterials nor Nucleic Acid Amplification
    (ACS Sensors, 2017) Ruiz Valdepeñas Montiel, Víctor; Povedano Muñumel, Eloy; Vargas, Eva; Torrente Rodríguez, Rebeca Magnolia; Pedrero Muñoz, María; Reviejo García, Ángel Julio; Campuzano Ruiz, Susana; Pingarrón Carrazón, José Manuel
    Currently, electrochemical nucleic acid-based biosensing methodologies involving hybridization assays, specific recognition of RNA/DNA and RNA/RNAduplexes, and amplification systems provide an attractive alternative to conventional quantification strategies for the routine determination of relevant nucleic acids at different settings. A particularly relevant objective in the development of such nucleic acid biosensors is the design of as many as possible affordable, quick, and simple methods while keeping the required sensitivity. With this aim in mind, this work reports, for the first time, a thorough comparison between 11 methodologies that involve different assay formats and labeling strategies for targeting the same DNA. The assayed approaches use conventional sandwich and competitive hybridization assays, direct hybridization coupled to bioreceptors with affinity for RNA/DNA duplexes, multienzyme labeling bioreagents, and DNA concatamers. All of them have been implemented on the surface of magnetic beads (MBs) and involve amperometrictransduction at screen-printed carbon electrodes (SPCEs). The influence of the formed duplex length and of the labeling strategy have also been evaluated. Results demonstrate that these strategies can provide very sensitive methods without the need for using nanomaterials or polymerase chain reaction (PCR). In addition, the sensitivity can be tailored within several orders of magnitude simply by varying the bioassay format, hybrid length or labeling strategy. This comparative study allowed us to conclude that the use of strategies involving longer hybrids, the use of antibodies with specificity for RNA/DNA heteroduplexes and labeling with bacterial antibody binding proteins conjugated with multiple enzyme molecules, provides the best sensitivity.
  • Item
    Rapid endoglin determination in serum samples using an amperometric magneto-actuated disposable immunosensing platform
    (Journal of Pharmaceutical and Biomedical Analysis, 2016) Torrente Rodríguez, Rebeca Magnolia; Campuzano Ruiz, Susana; Ruiz Valdepeñas Montiel, Víctor; Pedrero Muñoz, María; Fernández Aceñero, María Jesús; Barderas Manchado, Rodrigo; Pingarrón Carrazón, José Manuel
    A sensitive and rapid method for the determination of the clinically relevant biomarker human endoglin (CD105) in serum samples is presented, involving a magneto-actuated immunoassay and amperometric detection at disposable screen-printed carbon electrodes (SPCEs). Micro-sized magnetic particles were modified with a specific antibody to selectively capture the target protein which was further sandwiched with a secondary HRP-labeled antibody. The immunocomplexes attached to the magnetic carriers were amperometrically detected at SPCEs using the hydroquinone (HQ)/H2O2/HRP system. The magneto-actuated immunosensing platform was able to detect 5 pmoles of endoglin (in 25μL of sample, 0.2μM) in 30min providing statistically similar results to those obtained using a commercial ELISA kit for the determination of endogenous content of endoglin in human serum samples.