Person:
Sanz Fernández, Juan Carlos

Loading...
Profile Picture
First Name
Juan Carlos
Last Name
Sanz Fernández
Affiliation
Universidad Complutense de Madrid
Faculty / Institute
Óptica y Optometría
Department
Optometría y Visión
Area
Optica
Identifiers
UCM identifier

Search Results

Now showing 1 - 2 of 2
  • Item
    Visual outcomes after bilateral trifocal diffractive intraocular lens implantation
    (BMC Ophthalmology, 2015) Carballo Álvarez, Jesús; Vázquez Molini, José María; Sanz Fernández, Juan Carlos; García Bella, Javier; Polo Llorens, Vicente; García Feijoo, Julián; Martínez De La Casa Fernández-Borrella, José María
    Background In recent years new models of intraocular lenses are appearing on the market to reduce requirements for additional optical correction. The purpose of this study is to assess visual outcomes following bilateral cataract surgery and the implant of a FineVision® trifocal intraocular lens (IOL). Methods Prospective, nonrandomized, observational study. Vision was assessed in 44 eyes of 22 patients (mean age 68.4 ± 5.5 years) before and 3 months after surgery. Aberrations were determined using the Topcon KR-1 W wave-front analyzer. LogMAR visual acuity was measured at distance (corrected distance visual acuity, CDVA 4 m), intermediate (distance corrected intermediate visual acuity, DCIVA 60 cm) and near (distance corrected near visual acuity, DCNVA 40 cm). The Pelli-Robson letter chart and the CSV-1000 test were used to estimate contrast sensitivity (CS). Defocus curve testing was performed in photopic and mesopic conditions. Adverse photic phenomena were assessed using the Halo v1.0 program. Results Mean aberration values for a mesopic pupil diameter were: total HOA RMS: 0.41 ± 0.30 μm, coma: 0.32 ± 0.22 μm and spherical aberration: 0.21 ± 0.20 μm. Binocular logMAR measurements were: CDVA −0.05 ± 0.05, DCIVA 0.15 ± 0.10, and DCNVA 0.06 ± 0.10. Mean Pelli-Robson CS was 1.40 ± 0.14 log units. Mean CSV100 CS for the 4 frequencies examined (A: 3 cycles/degree (cpd), B: 6 cpd, C: 12 cpd, D: 18 cpd) were 1.64 ± 0.14, 1.77 ± 0.18, 1.44 ± 0.24 and 0.98 ± 0.24 log units, respectively. Significant differences were observed in defocus curves for photopic and mesopic conditions (p < 0.0001). A mean disturbance index of 0.28 ± 0.22 was obtained. Conclusions Bilateral FineVision IOL implant achieved a full range of adequate vision, satisfactory contrast sensitivity, and a lack of significant adverse photic phenomena. Trial registration Eudract Clinical Trials Registry Number: 2014-003266-2.
  • Item
    Visual outcomes after bilateral implantation of a new diffractive multifocal IOL: Preliminary results
    (2022) García Bella, Javier; Carballo Álvarez, Jesús; Collado Vincueria, Isabel; Sanz Fernández, Juan Carlos; García Feijoo, Julián; Martínez De La Casa Fernández-Borrella, José María; Vázquez Molini, José María
    Background: The aim was to determine visual outcomes and patient satisfaction in patients undergoing cataract surgery after the binocular implant of multifocal difractive Intensity IOL Methods: 21 patients were evaluated. Six weeks after surgery, uncorrected distance visual acuity(UDVA), corrected distance visual acuity(CDVA), distance corrected intermediate visual acuity at 60 cm(DCIVA) and distance corrected near visual acuity at 40cm (DCNVA) were determined using the ETDRS test. Defocus curves were produced both in photopic and mesopic conditions. Contrast sensitivity(CSF) was measured using the CSV-1000 test. Patients were shown pictures about dysphotopic phenomena and informed about their meaning with a likert scale from 0 (no problem) to 4 (overwhelming). Results: Post implantation mean logMAR Binocular UDVA, CDVA, DCIVA and DCNVA were 0.07± 0.09, -0.01 ± 0.04, 0.08 ± 0.05 and 0.12 ± 0.06 respectively. Photopic defocus curve showed a extended range of good vision. Mesopic defocus curve results were better than previously reported with trifocal designs. Mean binocular CSF values for 4 spatial frequencies (3, 6, 12 and 18 cpd) were 1.55±0.29, 1.60±0.17, 1.29±0.26 and 0.81±0.15 log. units, respectively. Halos were more frequent than starburst and glare with a Likert scale mean value of 0.86±0.83. Conclusions: The IOL provided a continuous range of vision from distance to near. Patients were not bothered or only slightly bothered in relation to the visual disturbances.