Person:
Campuzano Ruiz, Susana

Loading...
Profile Picture
First Name
Susana
Last Name
Campuzano Ruiz
Affiliation
Universidad Complutense de Madrid
Faculty / Institute
Ciencias Químicas
Department
Química Analítica
Area
Química Analítica
Identifiers
UCM identifierORCIDScopus Author IDDialnet IDGoogle Scholar ID

Search Results

Now showing 1 - 7 of 7
  • Item
    Toward Liquid Biopsy: Determination of the Humoral Immune Response in Cancer Patients Using HaloTag Fusion Protein-Modified Electrochemical Bioplatforms
    (Analytical Chemistry, 2016) Garranzo Asensio, María; Guzmán Aránguez, Ana Isabel; Povés Francés, Carmen; Fernández Aceñero, Mª Jesús; Torrente Rodríguez, Rebeca Magnolia; Ruiz Valdepeñas Montiel, Víctor; Domínguez Muñóz, Gemma; San Frutos Llorente, Luis; Rodríguez Salas, Nuria; Villalba Díaz, Mayte; Pingarrón Carrazón, José Manuel; Campuzano Ruiz, Susana; Barderas Manchado, Rodrigo
    Autoantibodies raised against tumor-associated antigens have shown high promise as clinical biomarkers for reliable diagnosis, prognosis, and therapy monitoring of cancer. An electrochemical disposable biosensor for the specific and sensitive determination of p53-specific autoantibodies has been developed for the first time in this work. This biosensor involves the use of magnetic microcarriers (MBs) modified with covalently immobilized HaloTag fusion p53 protein as solid supports for the selective capture of specific autoantibodies. After magnetic capture of the modified MBs onto screen-printed carbon working electrodes, the amperometric signal using the system hydroquinone/H2O2 was related to the levels of p53-autoantibodies in the sample. The biosensor was applied for the analysis of sera from 24 patients with high-risk of developing colorectal cancer and 6 from patients already diagnosed with colorectal (4) and ovarian (2) cancer. The developed biosensor was able to determine p53 autoantibodies with a sensitivity higher than that of a commercial standard ELISA using a just-in-time produced protein in a simpler protocol with less sample volume and easily miniaturized and cost-effective instrumentation.
  • Item
    Multiplexed biosensing diagnostic platforms detecting autoantibodies to tumor-associated antigens from exosomes released by CRC cells and tissue samples showed high diagnostic ability for colorectal cancer
    (Engineering, 2021) Montero Calle, Ana; Aranguren Abeigon, Itziar; Garranzo Asensio, María; Povés Francés, Carmen; Fernández Aceñero, María Jesús; Martínez Useros, Javier; Sanz, Rodrigo; Dziaková, Jana; Rodríguez Cobos, Javier; Solís Fernández, Guillermo; Povedano, Eloy; Gamella Carballo, Maria; Torrente Rodríguez, Rebeca Magnolia; Alonso Navarro, Miren; Ríos, Vivian de los; Casal, J. Ignacio; Domínguez Muñóz, Gemma; Guzmán Aránguez, Ana Isabel; Peláez García, Alberto, Alberto; Pingarrón Carrazón, José Manuel; Campuzano Ruiz, Susana; Barderas Manchado, Rodrigo
    Colorectal cancer (CRC) is the second leading cause of cancer-related death worldwide. The 5-year survival rate of CRC patients depends on the stage at diagnosis, being higher than 80% when CRC is diagnosed in the early stages but lower than 10% when CRC is diagnosed in advanced stages. Autoantibodies against specific CRC autoantigens (tumor-associated antigens (TAAs)) in the sera of patients have been widely demonstrated to aid in early diagnosis. Thus, we herein aim to identify autoantigens target of autoantibodies specific to CRC that possess a significant ability to discriminate between CRC patients and healthy individuals by means of liquid biopsy. To that end, we examined the protein content of the exosomes released by five CRC cell lines and tissue samples from CRC patients by means of immunoprecipitation coupled with mass spectrometry analysis. A total of 103 proteins were identified as potential autoantigens specific to CRC. After bioinformatics and meta-analysis, we selected 15 proteins that are more likely to be actual CRC autoantigens in order to evaluate their role in CRC prognosis by Western blot (WB) and immunohistochemistry (IHC). We found dysregulation at the protein level for 11 of these proteins in both tissue and plasma exosome samples from patients, along with an association of nine of these proteins with CRC prognosis. After validation, all but one showed a statistically significant high diagnostic ability to distinguish CRC patients and individuals with premalignant lesions from healthy individuals, either by luminescence Halotag-based beads, or by a multiplexed biosensing platform involving the use of magnetic microcarriers as solid support modified with covalently immobilized Halotag fusion proteins constructed for CRC detection. Taken together, our results highlight the usefulness of the approach defined here to identify the TAAs specific to chronic diseases; they also demonstrate that the measurement of autoantibody levels in plasma against the TAAs identified here could be integrated into a point-of-care (POC) device for CRC detection with high diagnostic ability.
  • Item
    p53 and p63 Proteoforms Derived from Alternative Splicing Possess Differential Seroreactivity in Colorectal Cancer with Distinct Diagnostic Ability from the Canonical Proteins
    (Cancers, 2023) Montero Calle, Ana; Garranzo Asensio, María; Torrente Rodríguez, Rebeca Magnolia; Ruiz Valdepeñas Montiel, Víctor; Poves, Carmen; Dziakova, Jana; Sanz, Rodrigo; Díaz Del Arco, Cristina; Pingarrón Carrazón, José Manuel; Fernández Aceñero, María Jesús; Campuzano Ruiz, Susana; Barderas Manchado, Rodrigo
    Colorectal cancer (CRC) is the third most common cancer and the second most frequent cause of cancer-related death worldwide. The detection in plasma samples of autoantibodies against specific tumor-associated antigens has been demonstrated to be useful for the early diagnosis of CRC by liquid biopsy. However, new studies related to the humoral immune response in cancer are needed to enable blood-based diagnosis of the disease. Here, our aim was to characterize the humoral immune response associated with the different p53 and p63 proteoforms derived from alternative splicing and previously described as aberrantly expressed in CRC. Thus, here we investigated the diagnostic ability of the twelve p53 proteoforms and the eight p63 proteoforms described to date, and their specific N-terminal and C-terminal end peptides, by means of luminescence HaloTag beads immunoassays. Full-length proteoforms or specific peptides were cloned as HaloTag fusion proteins and their seroreactivity analyzed using plasma from CRC patients at stages I-IV (n = 31), individuals with premalignant lesions (n = 31), and healthy individuals (n = 48). p53γ, Δ40p53β, Δ40p53γ, Δ133p53γ, Δ160p53γ, TAp63α, TAp63δ, ΔNp63α, and ΔNp63δ, together with the specific C-terminal end α and δ p63 peptides, were found to be more seroreactive against plasma from CRC patients and/or individuals with premalignant lesions than from healthy individuals. In addition, ROC (receiver operating characteristic) curves revealed a high diagnostic ability of those p53 and p63 proteoforms to detect CRC and premalignant individuals (AUC higher than 85%). Finally, electrochemical biosensing platforms were employed in POC-like devices to investigate their usefulness for CRC detection using selected p53 and p63 proteoforms. Our results demonstrate not only the potential of these biosensors for the simultaneous analysis of proteoforms’ seroreactivity, but also their convenience and versatility for the clinical detection of CRC by liquid biopsy. In conclusion, we here show that p53 and p63 proteoforms possess differential seroreactivity in CRC patients in comparison to controls, distinctive from canonical proteins, which should improve the diagnostic panels for obtaining a blood-based biomarker signature for CRC detection.
  • Item
    Multiplexed monitoring of a novel autoantibody diagnostic signature of colorectal cancer using HaloTag technology-based electrochemical immunosensing platform
    (Theranostics, 2020) Garranzo Asensio, María; Guzmán Aránguez, Ana Isabel; Povedano, Eloy; Ruiz Valdepeñas Montiel, Víctor; Povés Francés, Carmen; Fernández Aceñero, María Jesús; Montero Calle, Ana; Solís Fernández, Guillermo; Fernández Díez, Servando; Camps, Jordi; Arenas, Meritxell; Rodríguez Tomás, Elisabeth; Joven, Jorge; Sánchez Martínez, Maricruz; Rodrígez, Nuria; Domínguez Muñóz, Gemma; Yáñez Sedeño, Paloma; Pingarrón Carrazón, José Manuel; Campuzano Ruiz, Susana; Barderas Manchado, Rodrigo
    Background and Purpose: The humoral immune response in cancer patients can be used for early detection of the disease. Autoantibodies raised against tumor-associated antigens (TAAs) are promising clinical biomarkers for reliable cancer diagnosis, prognosis, and therapy monitoring. In this study, an electrochemical disposable multiplexed immunosensing platform able to integrate difficult- and easy-to-express colorectal cancer (CRC) TAAs is reported for the sensitive determination of eight CRC-specific autoantibodies. Methods: The electrochemical immunosensing approach involves the use of magnetic microcarriers (MBs) as solid supports modified with covalently immobilized HaloTag fusion proteins for the selective capture of specific autoantibodies. After magnetic capture of the modified MBs onto screen-printed carbon working electrodes, the amperometric responses measured using the hydroquinone (HQ)/H2O2 system were related to the levels of autoantibodies in plasma. Results: The biosensing platform was applied to the analysis of autoantibodies against 8 TAAs described for the first time in this work in plasma samples from healthy asymptomatic individuals (n=3), and patients with high-risk of developing CRC (n=3), and from patients already diagnosed with colorectal (n=3), lung (n=2) or breast (n=2) cancer. The developed bioplatform demonstrated an improved discrimination between CRC patients and controls (asymptomatic healthy individuals and breast and lung cancer patients) compared to an ELISA-like luminescence test. Conclusions: The proposed methodology uses a just-in-time produced protein in a simpler protocol, with low sample volume, and involves cost-effective instrumentation, which could be used in a high-throughput manner for reliable population screening to facilitate the detection of early CRC patients at affordable cost.
  • Item
    First bioelectronic immunoplatform for quantitative secretomic analysis of total and metastasis-driven glycosylated haptoglobin
    (Analytical and Bioanalytical Chemistry, 2022) Muñoz San Martín, Cristina; Montero Calle, Ana; Garranzo Asensio, María; Gamella Carballo, Maria; Pérez Ginés, Víctor; Pedrero Muñoz, María; Pingarrón Carrazón, José Manuel; Barderas, Rodrigo; Santos Álvarez, Noemí de los; Lobo Castañón, María Jesús; Campuzano Ruiz, Susana
    The glycosylation status of proteins is increasingly used as biomarker to improve the reliability in the diagnosis and prognosis of diseases as relevant as cancer. This feeds the need for tools that allow its simple and reliable analysis and are compatible with applicability in the clinic. With this objective in mind, this work reports the frst bioelectronic immunoplatforms described to date for the determination of glycosylated haptoglobin (Hp) and the simultaneous determination of total and glycosylated Hp. The bioelectronic immunoplatform is based on the implementation of non-competitive bioassays using two diferent antibodies or an antibody and a lectin on the surface of commercial magnetic microcarriers. The resulting bioconjugates are labeled with the horseradish peroxidase (HRP) enzyme, and after their magnetic capture on disposable electroplatforms, the amperometric transduction using the H2O2/hydroquinone (HQ) system allows the single or multiple detection. The developed immunoplatform achieves limits of detection (LODs) of 0.07 and 0.46 ng mL−1 for total and glycosylated Hp in bufer solution, respectively. The immunoplatform allows accurate determination using simple and relatively short protocols (approx. 75 min) of total and glycosylated Hp in the secretomes of in vitro–cultured colorectal cancer (CRC) cells with diferent metastatic potentials, which is not feasible, due to lack of sensitivity, by means of some commercial ELISA kits and Western blot methodology.
  • Item
    Disposable Amperometric Immunosensor for the Determination of Human P53 Protein in Cell Lysates Using Magnetic Micro-Carriers
    (Biosensors, 2016) Pedrero Muñoz, María; Manuel de Villena Rueda, Francisco Javier; Muñoz San Martín, Cristina; Campuzano Ruiz, Susana; Garranzo Asensio, María; Barderas Manchado, Rodrigo; Pingarrón Carrazón, José Manuel
    An amperometric magnetoimmunosensor for the determination of human p53 protein is described in this work using a sandwich configuration involving the covalent immobilization of a specific capture antibody onto activated carboxylic-modified magnetic beads (HOOC-MBs) and incubation of the modified MBs with a mixture of the target protein and horseradish peroxidase-labeled antibody (HRP-anti-p53). The resulting modified MBs are captured by a magnet placed under the surface of a disposable carbon screen-printed electrode (SPCE) and the amperometric responses are measured at −0.20 V (vs. an Ag pseudo-reference electrode), upon addition of hydroquinone (HQ) as a redox mediator and H2O2 as the enzyme substrate. The magnetoimmunosensing platform was successfully applied for the detection of p53 protein in different cell lysates without any matrix effect after a simple sample dilution. The results correlated accurately with those provided by a commercial ELISA kit, thus confirming the immunosensor as an attractive alternative for rapid and simple determination of this protein using portable and affordable instrumentation.
  • Item
    Angiogenesis inhibitor or aggressiveness marker? The function of endostatin in cancer through electrochemical biosensing
    (Bioelectrochemistry, 2024) Tejerina Miranda, Sandra; Pedrero Muñoz, María; Blázquez García, Marina; Serafín González-Carrato, Verónica; Montero Calle, Ana; Garranzo Asensio, María; Reviejo García, Ángel Julio; Pingarrón Carrazón, José Manuel; Barderas Manchado, Rodrigo; Campuzano Ruiz, Susana
    This work reports the first electrochemical bioplatform developed for the determination of human endostatin (HE), a biomarker with recognized antiangiogenic potential whose elevated circulating levels have also been associated with the development of aggressive cancers. The developed electroanalytical biotool combines the benefits of using magnetic microparticles for the implementation of sandwich immunoassays and amperometric transduction on disposable carbon electrodes. A limit of detection (LOD) of 34.1 pg mL−1 for HE standards and a selectivity suitable for its foray into the clinical oncology area, are demonstrated. The determination of HE in clinical samples such as lysates and secretomes of colorectal cancer (CRC) cells, plasma, and tissue samples from patients with CRC in different stages, has been faced with satisfactory results showing the ability for discriminating the metastatic capabilities of cells and for identifying and staging CRC patients. The developed bioplatform allows precise quantitative determinations, requiring minimal pre-treatments and sample amounts in only 75 min. In addition, due to the instrumentation and the type of substrates used in the detection step, the biotool is compatible with implementation in multiplexed and/or point-of-need devices, features in which this bioplatform is advantageous with respect to the enzyme linked immunosorbent assay (ELISA) or immunoblotting technologies.