Person:
Pérez Carrasco, María Jesús

Loading...
Profile Picture
First Name
María Jesús
Last Name
Pérez Carrasco
Affiliation
Universidad Complutense de Madrid
Faculty / Institute
Óptica y Optometría
Department
Optometría y Visión
Area
Optica
Identifiers
UCM identifierORCIDScopus Author IDWeb of Science ResearcherIDDialnet ID

Search Results

Now showing 1 - 9 of 9
  • Item
    Effect of a yellow filter on mesopic contrast perception and differential light sensitivity in the visual field.
    (Ophthalmic Research, 2003) Pérez Carrasco, María Jesús; Puell Marín, María Cinta; Sánchez Ramos, Celia; Langa Moraga, Antonio
    Purpose: Previous studies on the effects of yellow filters in the visual performance have been carried out, presenting discrepancies among the different investigations. Our study reports the influence of the yellow filter without residual reflections on contrast perception and differential light sensitivity (DLS) under mesopic conditions. Methods: Contrast sensitivity, low contrast visual acuity and luminance thresholds in the central visual field (30 degrees ) were measured in a group of 38 adult subjects with and without a coated yellow lens (482-nm cut-off) under mesopic conditions. Results: The contrast sensitivity mean was significantly better with the filter at low- and middle-range spatial frequencies (1.5 cycles/degree p = 0.002 and 6 cycles/degree p = 0.02). At 5% contrast, the mesopic low contrast visual acuity improved significantly (p = 0.004) when interposing the yellow filter. The increase in DLS was statistically significant [e.g. all visual fields p = 0.0003 and macular visual field (9.5 degrees ) p = 0.00001] through the yellow filter on the different established areas of the visual field (30 degrees ). Conclusions: The yellow filter without residual reflections had a positive influence on the brightness and contrast perception of healthy subjects, for which its use would be beneficial under mesopic conditions.
  • Item
    Nuevo instrumento para medir la sensibilidad al contraste sin y con deslumbramiento
    (Archivos de la Sociedad Española de Oftalmología, 2003) Sánchez Ramos, Celia; Puell Marín, María Cinta; Pérez Carrasco, María Jesús; Langa Moraga, Antonio; Benítez Del Castillo Sánchez, José Manuel
    OBJETIVO/MÉTODO: valorar la sensibilidad al contraste fotópica, sin y con deslumbramiento con un nuevo instrumento. Se estudiaron 78 ojos derechos de 49 adultos jóvenes y de 29 adultos entre 35 y 55 años. La sensibilidad al contraste se midió con el Contrast Glarester CGT-1000 mediante una estrategia automatizada de reconocimiento para seis frecuencias espaciales. RESULTADOS/CONCLUSIONES: Los valores de sensibilidad al contraste fueron semejantes a los obtenidos con otros test clínicos. El aumento de la edad disminuyó significativamente la sensibilidad al contraste sin y con deslumbramiento. Sin embargo, el deslumbramiento no modificó la sensibilidad al contraste fotópica.
  • Item
    Effect of Mesopic/Scotopic Luminance on Pupil Diameter and Anisocoria in Drivers Over 65 Years of Age
    (2005) Pérez Carrasco, María Jesús; Sánchez Ramos, Celia; Moral Martínez, M.I.; Puell Marín, María Cinta; Langa Moraga, Antonio
    Purpose: To evaluate the changes produced in pupil diameter and anisocoria in mesopic and scotopic conditions in subjects over the age of 65 years. Methods: A prospective evaluation was performed of pupil diameter in 45 motor car drivers aged 65 to 80 years (69±6 years). Measurements were made using an infrared, binocular pupillometer P2000 (Procyon Instruments Ltd) at 3 luminance levels: 0.04 lux (scotopic), 0.4 lux (low mesopic) and 4 lux (high mesopic). For each measurement, 10 photographs of both eyes are automatically taken by the instrument. Results: In scotopic conditions, mean pupil sizes were RE 5.37±1.1 mm, LE 5.29±1 mm. When the luminance level was increased to 0.4 lux (low mesopic conditions) mioses of 18% and 17%, respectively for the right and left eyes, were observed, resulting in pupil diameters of RE 4.55±0.83 mm, LE 4.51±0.78 mm. In high mesopic conditions (4 lux), pupil diameters were RE 3.47±0.60 mm, LE 3.41±0.89 mm, corresponding to mioses from the previous luminance level of 28% and 29%, respectively. The diferences in pupil diameter among the three luminance levels were significant. No diferences attributable to the luminance level were detected between each eye. The degrees of anisocoria observed were 5.77%, 5.78% and 5.77% in scotopic, low and high mesopic conditions, respectively. No significant diferences in scotopic/mesopic pupil sizes were revealed when the population was divided into three (15–year) age groups, or according to sex. Conclusions: At scotopic and mesopic luminance levels, drivers over 65 years show significant diferences in pupil diameter but no changes in anisocoria.
  • Item
    Mesopic contrast sensitivity and glare disability in drivers.
    (2003) Sánchez Ramos, Celia; Puell Marín, María Cinta; Pérez Carrasco, María Jesús; Langa Moraga, Antonio; Benítez Del Castillo Sánchez, José Manuel
    Visual Acuity is a poor predictor of driving ability and it is likely to be a poor predictor of many aspects of real-world vision, because the real world is not composed purely of fine objects with sharp edges at high contrast. Although not all objects are at contrst treshold either, it has been shown that a loss of contrast sensitivity (CS) is roughly equivalent to a loss of image contrast in the normal eye (OWSLEY, 1994). The extent of contrast loss required before real-world performance is reduced depends on the real-world task being performed. Somo tasks, such as optimal speed reading and mobility orientation in a well-llit room, tolerate large reductions in contrast (Elliot, 1996; Leffe, 1993; Pelli, 1986). These tasks would probably only be affected in patients with a severe loss of contrast sensitivity. However, other tasks such as speed reading newspaper-size print and face recognition are moderately affected by contrast reduction (Elliot, 1996). Further, mobility orientation under dim illumination has been shown to be seriously affected by reduced contrast. Thus, under low-iluminance conditions and when a subject is working near his or her acuity limit, tolerance to contrast loss is reduced (Legge, 1993)
  • Item
    Age effects on mesopic and scotopic anisocoria determined in vehicle drivers.
    (2005) Sánchez Ramos, Celia; Puell Marín, María Cinta; Pérez Carrasco, María Jesús; Langa Moraga, Antonio; Moral Martínez, M.I.
    The diameter of the pupil affects a person´s vision in a complex manner. As the pupil dilates, it allows more light to enter the eye and stimulate the retina, reducing blur caused by diffraction to a minimum. A narrow pupil, on the other hand, reduces the negative effects of these aberrations on the crystaline lens. In general, a pupil diameter of 3 to 6 mm increases clarity of vision. Owing to the adaptation process, humans can tolerate a difference in luminance conditions from 1 to 10000000 cd/m2. The spectrum of visual sensitivity is so broad that in a graph, the intensity of light has to be plotted on a logarithmic scale.
  • Item
    Características funcionales y ergonómicas de las lentes ocupacionales.
    (2005) Sánchez Ramos, Celia; Moral Martínez, M.I.; Alonso Fernández, José; Puell Marín, María Cinta; Langa Moraga, Antonio; Pérez Carrasco, María Jesús
    El propósito de este trabajo ha sido evaluar tanto objetiva como subjetivamente las características ergonómicas y funcionales de las lentes ocupacionales, comparándolas con las lentes monofocales convencionales. Esta evaluación se ha realizado con pruebas psicofísicas como sensibilidad al contraste, agudeza visual de contraste variable, y perimetría FDT, además de con un cuestionario subjetivo. La muestra ha estado compuesta por 30 pacientes con edades comprendidas entre 40 y 58 años. Las conclusiones indican que tanto objetiva como subjetivamente se obtienen diferencias por el uso de las lentes ocupacionales.
  • Item
    Agudeza visual Snellen versus agudeza visual medida por interferencia.
    (1996) Langa Moraga, Antonio; Sánchez Ramos, Celia; Puell Marín, María Cinta; Pérez Carrasco, María Jesús
    Los test de interferencias para la agudeza visual permiten la función macular con independencia del estado del sistema óptico ocular, siendo de gran inte´res por ser un método objetivo, además de ser útil cuando los medios oculares presentan opacidades. Nuestro objetivo es investigar en población joven universitaria la relación existente entre los valores de agudeza visual obtenidos con la E de Snellen y los obtenidos con el IRAS GT 761, con objeto hacer una valoración de este nuevo método de medida y evaluar la posible pérdida de agudeza visual debida al sistema óptico.
  • Item
    Efecto del hialuronato sódico (0.15%) en la sensibilidad al contraste en ojo seco con déficit hormonal.
    (2005) Sánchez Ramos, Celia; Llorens Casado, María Belén; Moral Martínez, I.; Puell Marín, María Cinta; Gonzalvo, M.T.; Pérez Carrasco, María Jesús; Langa Moraga, Antonio; Benítez Del Castillo Sánchez, José Manuel; Sáenz Francés, F.
    Los cambios de la actividad metabólica inducidos por las variaciones hormonales producen síntomas asociados, como la patología del "ojo seco". El tratamiento más frecuente para la sequedad ocular es la aplicación de lágrimas artificiales. El hialuronato sódico es uno de los fármacos que reconstruye la película lagrimal. No obstante, se desconoce su efecto en la percepción visual, especialmente en los que respeta a su posible repercusión en la sensibilidad al contraste y más concretamente en pacientes postmenopáusicas que presentan patología de "ojo seco". Por ello se plantea este estudio, cuyo objetivo es valorar la eficacia del hialuronato sódico en mujeres potmenopáusicas que sufren esta patología, mediante la determinación de las variaciones en su función de la sensibilidad al contraste.
  • Item
    Eficacia bloqueante de filtros amarillos artificiales en procesos de degeneración retiniana
    (2005) Sánchez Ramos, Celia; Benítez Del Castillo Sánchez, José Manuel; Moral Martínez, M.I.; Sáenz Francés, F.; Álvarez, A.; Pérez Carrasco, María Jesús; Puell Marín, María Cinta; Langa Moraga, Antonio
    El ojo dispone de un sistema de protección combinado que consiste evitar que las neuronas maculares absorban la luz visible azul. La protección retineana natural está sustentada por cromóforos producidos en el proceso de madurez y envejecimiento del cristalino y por pigmentos maculares: carotenoides- luteína y zeaxantina. Con la extracción del cristalino, en ojos operados de cataratas, se eliminan con la lente los cromóforos, dejando la retina expuesta a la acción de longitudes de onda corta que producen daños irreversibles. El propósito de este trabajo es comparar el efecto bloqueante de las sustancias amarillas naturales y de os filtros artificiales así como su papel protector en procesos evolutivos de degeneración macular asociada a la edad. La tomografía de coherencia óptica es una innovadora tecnología imprescindible para valorar la evolución de los procesos degenerativos del epitelio pigmentario, de la capa de neuronas ganglionares y de los fotorreceptores de la retina. En esta investigación se ha diseñado un estudio transversal y longitudinal de tres años de duración en ojos vivos viejos psudoafáquicos. Se realiza cirugía de catarata extracapsular con implantación de lente intraocular transparentes o con filtro amarillo en el saco capsular de conejos pigmentados mayores de dos años. Los animales erán expuestos a la cantidad variable de luz blanca y luz azul según el grupo. Para la evolución histológica se utilizará el instrumento de tomografía de coherencia óptica.