Person:
Martínez Alberquilla, Irene

Loading...
Profile Picture
First Name
Irene
Last Name
Martínez Alberquilla
Affiliation
Universidad Complutense de Madrid
Faculty / Institute
Óptica y Optometría
Department
Optometría y Visión
Area
Identifiers
UCM identifierScopus Author IDDialnet ID

Search Results

Now showing 1 - 6 of 6
  • Item
    The role of clinical diagnosis criteria on the frequency of accommodative insufficiency
    (International journal of ophthalmology, 2019) García Montero, María; Antona Peñalba, Beatriz; Barrio de Santos, Ana Rosa; Nieto Zayas, Carmen; Martínez Alberquilla, Irene; Hernández Verdejo, José Luis
    AIM: To estimate and compare the frequency of accommodative insufficiency (AI) within the same clinical population sample depending on the type of clinical criteria used for diagnosis. Comparing the frequency within the same population would help to minimize bias due to sampling or methodological variability. METHODS: Retrospective study of 205 medical records of symptomatic subjects free of any organic cause and symptoms persisting despite optical compensation evaluated. Based on the most commonly clinical diagnostics criteria found in the literature, four diagnostics criteria were established for AI (I, II, III and IV) based on subjective accommodative tests: monocular accommodative amplitude two or more diopters below Hofstetter’s minimum value [15-(0.25×age)] (I, II, III, IV); failing monocular accommodative facility with minus lens, establishing the cut-off in 0 cycles per minute (cpm) (I) and in 6 cpm (II, III); failing binocular accommodative facility with minus lens, establishing the cut-off in 0 cpm (I) and in 3 cpm (II). RESULTS: The proportion of AI (95%CI) for criteria I, II, III and IV were 1.95% (0.04%-3.86%), 2.93% (0.31%-4.57%), 6.34% (1.90%-7.85%) and 41.95% (35.14%-48.76%) respectively, with a statistically significant difference shown between these values (χ2=226.7, P<0.001). A pairwise multiple comparison revealed that the proportion of AI detected for criterion IV was significantly greater than the proportion for the rest of the criteria (P-adjusted<0.05 in all cases). CONCLUSION: The prevalence of cases of AI within the same clinical population varies with the clinical diagnostic criteria selected. The variation is statistically significant when considering the monocular accommodative amplitude as the only clinical diagnostic sign.
  • Item
    Effects of Blink Rate on Tear Film Optical Quality Dynamics with Different Soft Contact Lenses
    (Journal of Ophthalmology, 2019) García Montero, María; Rico del Viejo, Laura; Martínez Alberquilla, Irene; Hernández Verdejo, José Luis; Lorente Velázquez, Amalia; Madrid Costa, David
    Objective. The aim of this study was to investigate tear film optical quality dynamics for four types of silicone hydrogel contact lenses (SHCLs) for daily wear over a 15-day period and for different blink rate (BR) patterns. Methods. A prospective randomized, double-blind, cross-over pilot study including four SHCLs (A: lotrafilcon B (Air Optix plus HydraGlyde, Alcon Laboratories); B: samfilcon A (Ultra, Bausch & Lomb); C: comfilcon A (Biofinity, CooperVision); and D: filcom V3 (Blu:gen, Mark’Ennovy)). Serial measurements of Objective Scatter Index (OSI) using the HD Analyzer (Visiometrics S.L., Terrassa, Spain) were taken at different blinking patterns: blinking every 2.5 seconds (high BRs) and every 9 seconds (low BRs). They were performed during the first visit before CL insertion (baseline), after 20 minutes of CL wear (Day 1), and during the last visit after 8 hours of CL wear on day 15 of use (Day 15). Results. Normal young healthy subjects were recruited and fitted with the four lenses. For low BRs, the mean OSI value increased over time for all CLs and the slope of the curve also increased for all CLs, except for CL D. However, for high BRs, the mean OSI value increased only for CLs B and C and the slope of the curve did not change over time for any of them. Conclusions. These results suggest that the tear film optical quality dynamics after wearing SCHLs for 15 days seems to undergo a slight deterioration only for lowest BR.
  • Item
    Repeatability of Noninvasive Keratograph 5M Measurements Associated With Contact Lens Wear
    (Eye & Contact lens, 2019) García Montero, María; Rico del Viejo, Laura; Lorente Velázquez, Amalia; Martínez Alberquilla, Irene; Hernández Verdejo, José Luis; Madrid Costa, David
    Objetive: To assess the intrarater repeatability of the measurements of tear meniscus height (TMH), noninvasive keratograph tear break-up time (NIKBUTs), and ocular redness measurements obtained with the Keratograph 5M (K5M) in a sample of soft silicone hydrogel contact lens (CL) wearers over 15 days. Methods: Prospective study over two consecutive weeks. Three measurements of TMH, NIKBUTs (NIKBUT first and NIKBUT average), and ocular redness were obtained in different sessions; the first day (baseline, at 8 hr of wear, and after lens removal) and the last day of wear-15th day (at 8 hr of wear and after lens removal). The repeatability of measurements were assessed by two intraclass correlation coefficient (ICC) forms; single measurement [ICC (2,1)] and multiple measurements (k=3) [ICC (2, k)]. Results: Sixty-four eyes were analyzed. The repeatability of baseline TMH [ICC (2,1) greater than 0.90; coefficient of repeatability (CR)=0.06 mm] and after and during CL wear [ICC (2,k) greater than 0.90; CR≤0.07 mm] were excellent. The repeatability of baseline NIKBUT average [ICC (2,k)=0.89 (0.82-0.93); CR=6.07 sec] was maintained after CL removal but was poorer during CL wear. The repeatability of baseline NIKBUT first [ICC (2,k) =0.80 (0.69-0.87); CR=8.74 sec] was maintained after CL removal and during CL wear at moderate-good level. Conclusions: Intrarater repeatability of TMH, NIKBUTs, and ocular redness performed by K5M after CL wear remains stable when three measurements are performed. However, intrarater repeatability during CL wear decreased only for NIKBUT average and was not affected by time of use (15 days).
  • Item
    Project number: 202
    Aplicación de un programa informatizado para emitir informes clínicos en la asignatura de Clínica Optométrica I
    (2019) García Montero, María; Hernández Verdejo, José Luis; Madrid Costa, David; Gómez Sanz, Fernando Javier; Lorente Velázquez, Amalia; Rico Del Viejo, Laura; Martínez Alberquilla, Irene
    El objetivo es optimizar el uso de un programa informático de registro y almacenamiento de datos clínicos y la creación de una nueva herramienta para generar informes clínicos. Los informes clínicos forman parte de la evaluación del alumno.
  • Item
    PhDAY 2020 -FOO (Facultad de Óptica y Optometría)
    (2020) Pintor Just, Jesús Jerónimo; Carpena Torres, Carlos; Peral Cerda, María Asunción; Pérez de Lara, María Jesús; Toral, Fernando; Crooke Álvarez, Almudena; Pastrana Robles, Cristina; Carracedo Rodríguez, Juan Gonzalo; Cayuela López, Ana; Sorzano Sánchez, Óscar; Charbel, Carla; Garzón Jiménez, Nuria; Carballo Álvarez, Jesús; Diz Arias, Elena; Fernández Jiménez, Elena; Lledó Mayans, Victoria Eugenia; Gómez Pedrero, José Antonio; Durán Prieto, Elena; López Alonso, José Manuel; Fernández Torres, Miguel Ángel; Guzmán Aránguez, Ana Isabel; Gómez Manzanares, Ángela; Vázquez Molini, Daniel; Martínez Antón, Juan Carlos; Bernárdez Vilaboa, Ricardo; Mayorga Pinilla, Santiago; Álvarez Fernández-Balbuena, Antonio; Benítez, AntoJ.; Igalla El-Youssfi, Asmae; León Álvarez, Alejandro; Palomo Álvarez, Catalina; Awad Alkozi, Hanan; Sánchez Naves, Juan; Martínez Alberquilla, Irene; García Montero, María; Ruiz Alcocer, Javier; Madrid Costa, David; Martínez Florentín, Gema; Papas, Eric B.; Medrano Muñoz, Sandra Milena; Molina, Nancy; Jurado, Sandra; Oliveiros López, Juan; Platero Alvarado, Nadiuska Cristine; Garrido Mercado, Rafaela; Pérez Garmendia, Carlos; Antona Peñalba, Beatriz; Barrio De Santos, Ana Rosa; González Pérez, Mariano; Pérez Garmendia, Carlos; Serramito Blanco, María; Privado Aroco, Ana; Almalki, Wael; Bodas Romero, Julia; Ouzzani, Mohamed; Paune, Jaume; Calderón García, Raquel; Pitarch Velasco, Aída; Cebrián, José Luis; Sánchez Pérez, María Isabel; García Rojo, Marta María; Bonnin Arias, Cristina Natalia; Sánchez Ramos, Celia; Gutiérrez Jorrín, Sara Carmen; Rodríguez Alonso, Xabier; Laucirica Sáenz, Gorka; Arranz Márquez, Esther; Alonso Castellanos, Miriam; Teus Guezala, Miguel Ángel; Hernández Verdejo, José Luis; Mármol Errasti, Esther; Martín García, Beatriz; Arriola Villalobos, Pedro; Gómez De Liaño Sánchez, María Rosario; Mínguez Caro, N; Orduña Azcona, Javier; Navarro Gil, Francisco Javier; Huete Toral, Fernando; Rodríguez Pomar, Candela; Martínez Águila, Alejandro; Martín Gil, Alba; Tomé de la Torre, Miguel Ángel
    Por cuarto año consecutivo los doctorandos de la Facultad de Óptica y Optometría de la Universidad Complutense de Madrid cuentan con un congreso propio organizado por y para ellos, el 4º PhDAY- FOO. Se trata de un congreso gratuito abierto en la que estos jóvenes científicos podrán presentar sus investigaciones al resto de sus compañeros predoctorales y a toda la comunidad universitaria que quiera disfrutar de este evento. Apunta en tu agenda: el 15 de octubre de 2020. En esta ocasión será un Congreso On-line para evitar que la incertidumbre asociada a la pandemia Covid-19 pudiera condicionar su celebración.
  • Item
    Project number: 274
    Innovación docente en Prácticas de la asignatura Optometría V del Grado en Óptica y Optometría de la UCM
    (2021) García Montero, María; Hernández Verdejo, José Luis; Vázquez Molini, José María; Gómez Sanz, Fernando Javier; Martínez Alberquilla, Irene
    El desarrollo de las prácticas de esta asignatura tiene un componente teórico previo a la ejecución práctica y, en consecuencia, el uso de material en video que favorezcan un aprendizaje on-line activo, autónomo y colaborativo es de vital importancia en conceptos claves. Además, la resolución de casos clínicos a través de cuestiones auto-evaluativas fomenta el aprendizaje clínico basado en el desarrollo de las consultas optométricas con este tipo de pacientes.