Person:
Martínez Alberquilla, Irene

Loading...
Profile Picture
First Name
Irene
Last Name
Martínez Alberquilla
Affiliation
Universidad Complutense de Madrid
Faculty / Institute
Óptica y Optometría
Department
Optometría y Visión
Area
Identifiers
UCM identifierScopus Author IDDialnet ID

Search Results

Now showing 1 - 5 of 5
  • Item
    Effects of Blink Rate on Tear Film Optical Quality Dynamics with Different Soft Contact Lenses
    (Journal of Ophthalmology, 2019) García Montero, María; Rico del Viejo, Laura; Martínez Alberquilla, Irene; Hernández Verdejo, José Luis; Lorente Velázquez, Amalia; Madrid Costa, David
    Objective. The aim of this study was to investigate tear film optical quality dynamics for four types of silicone hydrogel contact lenses (SHCLs) for daily wear over a 15-day period and for different blink rate (BR) patterns. Methods. A prospective randomized, double-blind, cross-over pilot study including four SHCLs (A: lotrafilcon B (Air Optix plus HydraGlyde, Alcon Laboratories); B: samfilcon A (Ultra, Bausch & Lomb); C: comfilcon A (Biofinity, CooperVision); and D: filcom V3 (Blu:gen, Mark’Ennovy)). Serial measurements of Objective Scatter Index (OSI) using the HD Analyzer (Visiometrics S.L., Terrassa, Spain) were taken at different blinking patterns: blinking every 2.5 seconds (high BRs) and every 9 seconds (low BRs). They were performed during the first visit before CL insertion (baseline), after 20 minutes of CL wear (Day 1), and during the last visit after 8 hours of CL wear on day 15 of use (Day 15). Results. Normal young healthy subjects were recruited and fitted with the four lenses. For low BRs, the mean OSI value increased over time for all CLs and the slope of the curve also increased for all CLs, except for CL D. However, for high BRs, the mean OSI value increased only for CLs B and C and the slope of the curve did not change over time for any of them. Conclusions. These results suggest that the tear film optical quality dynamics after wearing SCHLs for 15 days seems to undergo a slight deterioration only for lowest BR.
  • Item
    Repeatability of Noninvasive Keratograph 5M Measurements Associated With Contact Lens Wear
    (Eye & Contact lens, 2019) García Montero, María; Rico del Viejo, Laura; Lorente Velázquez, Amalia; Martínez Alberquilla, Irene; Hernández Verdejo, José Luis; Madrid Costa, David
    Objetive: To assess the intrarater repeatability of the measurements of tear meniscus height (TMH), noninvasive keratograph tear break-up time (NIKBUTs), and ocular redness measurements obtained with the Keratograph 5M (K5M) in a sample of soft silicone hydrogel contact lens (CL) wearers over 15 days. Methods: Prospective study over two consecutive weeks. Three measurements of TMH, NIKBUTs (NIKBUT first and NIKBUT average), and ocular redness were obtained in different sessions; the first day (baseline, at 8 hr of wear, and after lens removal) and the last day of wear-15th day (at 8 hr of wear and after lens removal). The repeatability of measurements were assessed by two intraclass correlation coefficient (ICC) forms; single measurement [ICC (2,1)] and multiple measurements (k=3) [ICC (2, k)]. Results: Sixty-four eyes were analyzed. The repeatability of baseline TMH [ICC (2,1) greater than 0.90; coefficient of repeatability (CR)=0.06 mm] and after and during CL wear [ICC (2,k) greater than 0.90; CR≤0.07 mm] were excellent. The repeatability of baseline NIKBUT average [ICC (2,k)=0.89 (0.82-0.93); CR=6.07 sec] was maintained after CL removal but was poorer during CL wear. The repeatability of baseline NIKBUT first [ICC (2,k) =0.80 (0.69-0.87); CR=8.74 sec] was maintained after CL removal and during CL wear at moderate-good level. Conclusions: Intrarater repeatability of TMH, NIKBUTs, and ocular redness performed by K5M after CL wear remains stable when three measurements are performed. However, intrarater repeatability during CL wear decreased only for NIKBUT average and was not affected by time of use (15 days).
  • Item
    The Topographical Effect of Optical Zone Diameter in Orthokeratology Contact Lenses in High Myopes
    (Journal of Ophthalmology, 2019) Carracedo Rodríguez, Juan Gonzalo; Espinosa Vidal, Teresa M.; Martínez Alberquilla, Irene; Batres Valderas, Laura
    Purpose. To evaluate the effect of the optical zone diameter (OZ) in orthokeratology contact lenses regarding the topographical profile in patients with high myopia (−4.00 D to −7.00 D) and to study its effect over the visual quality. Materials and Methods. Twelve patients (18 eyes) were fitted with overnight orthokeratology (OrthoK) with a randomized 6 mm or 5 mm OZ lens worn for 2 weeks, followed by a 2-week washout period, between both designs. Keratometry (K) readings, optical zone treatment diameter (OZT), peripheral ring width (PRW), higher-order aberrations (HOA), high (HC) and low contrast (LC) visual acuity, and subjective vision and comfort were measured at baseline and after 2 weeks of OrthoK lens wear of each contact lens. Results. No significant differences were found between any measurements for the same subject at both baselines ( value > 0.05). There was no difference between OZ lens designs found in refraction, subjective vision or comfort, and HC and LC visual acuity. Contrast sensitivity was decreased in the 5 mm OZ lens design compared with 6 mm OZ design (-value < 0.05). 5 mm OZ design provoked a greater flattening, more powerful midperipheral ring and 4th-order corneal and total spherical aberration than the 6 mm OZ design, being statistically significant after 7 days, for corneal aberration, and 15 days, for corneal and total, of wearing the lens (-value < 0.05). The OZT obtained were 2.8 ± 0.2 mm and 3.1 ± 0.1 mm for 5 mm and 6 mm OZ design, respectively (-value < 0.05). Regarding PRW, the 5 mm OZ design had a wider ring width in both the nasal and temporal zones (-value < 0.05). Conclusions. A smaller diameter optical zone (5 mm) in orthokeratology lenses produces a smaller treatment area and a larger and more powerful midperipheral ring, increasing the 4th-order spherical aberration that affects only the contrast sensitivity but without differences in visual acuity and subjective vision compared with a larger OZ diameter (6 mm).
  • Item
    Impact of contact lens wear on NLRP3 gene expression: Implications for ocular frailty in middle-aged adults
    (Experimental Eye Research, 2020) Crooke Álvarez, Almudena; Martínez Alberquilla, Irene; García Montero, María; Rico Del Viejo, Laura; Ruiz Alcocer, Javier; Madrid Costa, David
    The inflammatory process plays a crucial role in frailty syndrome, which can appear in middle age and is associated with a poor health outcome. Consequently, gerontologists recommend screening inflammatory biomarkers in middle-aged adults to detect frailty and, therefore, prevent chronic diseases and mortality. External factors could be a risk factor for frailty because they can generate and extend the inflammatory process. For these reasons, we analysed the effect of long-term contact lens wear on mRNA level of genes linked to inflammation (IL-6, NLRP3, NK1R, CD73, MUC16 and TRPV1 genes) in conjunctival cells of middle-aged individuals, by quantitative PCR. Middle-aged contact lens wearers presented a significant increase of NLRP3 and MUC16 mRNA level as well as a decrease of CD73 mRNA level, in comparison with non-contact lens wearers. Additionally, we checked for a potential correlation between these transcript levels and clinical changes of the participants’ ocular surface. Unlike molecular analysis, clinical examination fails to detect inflammation in contact lens wearers. These data suggest that long-term contact lens wear could trigger an inflammatory response in middle age orchestrated by NLRP3 inflammasome and modulated by CD73 and MUC16 proteins. Further studies are needed to confirm our gene expression findings at the protein level as well as to investigate the potential role of long-term CL wear in the onset of ocular frailty.
  • Item
    Visual function, ocular surface integrity and symptomatology of a new extended depth-of-focus and a conventional multifocal contact lens
    (Contact Lens and Anterior Eye, 2020) Martínez Alberquilla, Irene; García Montero, María; Ruiz Alcocer, Javier; Crooke Álvarez, Almudena; Madrid Costa, David
    Purpose: To evaluate visual function, ocular surface integrity and dry eye symptoms with an extended depth-of-focus (EDOF) design and a conventional multifocal (MF) contact lens (CL) after 15 days of wear. Methods: A crossover single mask randomised clinical trial was conducted including 30 presbyopes who used an EDOF and a conventional MF CL (Biofinity MF) for 15 days each. Defocus curves, depth-of-focus range, contrast sensitivity (CS) under photopic and mesopic conditions (with and without glare) and subjective perception of halos and glare were evaluated. The ocular surface was evaluated through non-invasive Keratograph tear breakup time (NIKBUT), averaged tear breakup time (NIKBUT-avg), tear meniscus height (TMH), bulbar and limbal redness, and conjunctival and corneal staining. Dry eye symptoms were assessed with the OSDI questionnaire. Results: No statistically significant differences were found for defocus curves or depth-of-focus between the two CLs (both p > 0.05). Subjective perception of halos and glare was not significantly different between CLs. Statistically significant differences were observed for CS under mesopic conditions for low spatial frequencies (p = 0.008). None of the CL produced significant changes in NIKBUT, NIKBUT-avg, TMH or redness. No change in conjunctival staining was observed in 76.7 % and 73.3 % of participants for EDOF and Biofinity MF, respectively. No change in corneal staining was observed in 86.7 % and 83.3 % of participants for EDOF and Biofinity MF, respectively. No changes were observed in the symptomatology measured with OSDI questionnaire (p > 0.05). Conclusions: Both CL for presbyopia offer good visual quality, preserve the ocular surface integrity and provide the patient with similar symptomatology levels after 15 days of lens wear.