Person:
Pingarrón Carrazón, José Manuel

Loading...
Profile Picture
First Name
José Manuel
Last Name
Pingarrón Carrazón
Affiliation
Universidad Complutense de Madrid
Faculty / Institute
Ciencias Químicas
Department
Area
Química Analítica
Identifiers
UCM identifierORCIDScopus Author IDWeb of Science ResearcherIDDialnet IDGoogle Scholar ID

Search Results

Now showing 1 - 10 of 71
  • Item
    Amperometric Immunosensing Scaffolds for Rapid, Simple, Non-Invasive and Accurate Determination of Protein Biomarkers of Well-Accepted and Emerging Clinical Importance
    (Proceedings, 2017) Pedrero Muñoz, María; Muñoz San Martín, Cristina; Torrente Rodríguez, Rebeca Magnolia; Ruiz Valdepeñas Montiel, Víctor; Vargas Orgaz, Eva; Manuel de Villena Rueda, Francisco Javier; Barderas Manchado, Rodrigo; Campuzano Ruiz, Susana; Pingarrón Carrazón, José Manuel
  • Item
    Dextran-coated nanoparticles as immunosensing platforms: Consideration of polyaldehyde density, nanoparticle size and functionality
    (Talanta, 2022) Gao, Shipeng; Torrente Rodríguez, Rebeca M.; Pedrero Muñoz, María; Pingarrón Carrazón, José Manuel; Campuzano Ruiz, Susana; Rocha Martin, Javier; Guisán, José M.
    Magnetic nanoparticles (MNPs) can be used as antibody carriers in a wide range of immunosensing applications. The conjugation chemistry for preparing antibody-MNP bionanohybrids should assure the nanoparticle’s colloidal dispersity, directional conformation and high biofunctionality retention of attached antibodies. In this work, peroxidase (HRP) was selected as model target analyte, and stable antibody-MNP conjugates were prepared using polyaldehyde-dextrans as multivalent linkers, also to prevent nanoparticles agglomeration and steric shielding of non-specific proteins. Under the manipulation of the oxidation variables, MNP-conjugated antibody showed the highest Fab accessibility, of 1.32 μmol analyte per μmol antibody, corresponding to 139 μmol aldehyde per gram of nanocarrier (5 mM NaIO4, 4 h). Demonstrating anti-interference advantage up to 10% serum, colorimetric immunoassay gave a detection limit (LOD) of 300 ng mL− 1 , while electrochemical transduction led to a considerable (680 times) improvement, with a LOD of 0.44 ng mL− 1 . In addition, polyaldehydedextran showed priority over polycarboxylated-dextran as the multivalent antibody crosslinker for MNPs in terms of sensitivity and LOD value, while immunosensors constructed with carboxylated magnetic microbeads (HOOC-MBs) outperformed MNPs-based immunoplatforms. This work sheds light on the importance of surface chemistry (type and density of functional groups) and the dimension (nanosize vs micrometer) of magnetic carriers to conjugate antibodies with better directional orientation and improve the analytical performance of the resulting immunosensors.
  • Item
    Toward Liquid Biopsy: Determination of the Humoral Immune Response in Cancer Patients Using HaloTag Fusion Protein-Modified Electrochemical Bioplatforms
    (Analytical Chemistry, 2016) Garranzo Asensio, María; Guzmán Aránguez, Ana Isabel; Povés Francés, Carmen; Fernández Aceñero, Mª Jesús; Torrente Rodríguez, Rebeca Magnolia; Ruiz Valdepeñas Montiel, Víctor; Domínguez Muñóz, Gemma; San Frutos Llorente, Luis; Rodríguez Salas, Nuria; Villalba Díaz, Mayte; Pingarrón Carrazón, José Manuel; Campuzano Ruiz, Susana; Barderas Manchado, Rodrigo
    Autoantibodies raised against tumor-associated antigens have shown high promise as clinical biomarkers for reliable diagnosis, prognosis, and therapy monitoring of cancer. An electrochemical disposable biosensor for the specific and sensitive determination of p53-specific autoantibodies has been developed for the first time in this work. This biosensor involves the use of magnetic microcarriers (MBs) modified with covalently immobilized HaloTag fusion p53 protein as solid supports for the selective capture of specific autoantibodies. After magnetic capture of the modified MBs onto screen-printed carbon working electrodes, the amperometric signal using the system hydroquinone/H2O2 was related to the levels of p53-autoantibodies in the sample. The biosensor was applied for the analysis of sera from 24 patients with high-risk of developing colorectal cancer and 6 from patients already diagnosed with colorectal (4) and ovarian (2) cancer. The developed biosensor was able to determine p53 autoantibodies with a sensitivity higher than that of a commercial standard ELISA using a just-in-time produced protein in a simpler protocol with less sample volume and easily miniaturized and cost-effective instrumentation.
  • Item
    Multiplexed biosensing diagnostic platforms detecting autoantibodies to tumor-associated antigens from exosomes released by CRC cells and tissue samples showed high diagnostic ability for colorectal cancer
    (Engineering, 2021) Montero Calle, Ana; Aranguren Abeigon, Itziar; Garranzo Asensio, María; Povés Francés, Carmen; Fernández Aceñero, María Jesús; Martínez Useros, Javier; Sanz, Rodrigo; Dziaková, Jana; Rodríguez Cobos, Javier; Solís Fernández, Guillermo; Povedano, Eloy; Gamella Carballo, Maria; Torrente Rodríguez, Rebeca Magnolia; Alonso Navarro, Miren; Ríos, Vivian de los; Casal, J. Ignacio; Domínguez Muñóz, Gemma; Guzmán Aránguez, Ana Isabel; Peláez García, Alberto, Alberto; Pingarrón Carrazón, José Manuel; Campuzano Ruiz, Susana; Barderas Manchado, Rodrigo
    Colorectal cancer (CRC) is the second leading cause of cancer-related death worldwide. The 5-year survival rate of CRC patients depends on the stage at diagnosis, being higher than 80% when CRC is diagnosed in the early stages but lower than 10% when CRC is diagnosed in advanced stages. Autoantibodies against specific CRC autoantigens (tumor-associated antigens (TAAs)) in the sera of patients have been widely demonstrated to aid in early diagnosis. Thus, we herein aim to identify autoantigens target of autoantibodies specific to CRC that possess a significant ability to discriminate between CRC patients and healthy individuals by means of liquid biopsy. To that end, we examined the protein content of the exosomes released by five CRC cell lines and tissue samples from CRC patients by means of immunoprecipitation coupled with mass spectrometry analysis. A total of 103 proteins were identified as potential autoantigens specific to CRC. After bioinformatics and meta-analysis, we selected 15 proteins that are more likely to be actual CRC autoantigens in order to evaluate their role in CRC prognosis by Western blot (WB) and immunohistochemistry (IHC). We found dysregulation at the protein level for 11 of these proteins in both tissue and plasma exosome samples from patients, along with an association of nine of these proteins with CRC prognosis. After validation, all but one showed a statistically significant high diagnostic ability to distinguish CRC patients and individuals with premalignant lesions from healthy individuals, either by luminescence Halotag-based beads, or by a multiplexed biosensing platform involving the use of magnetic microcarriers as solid support modified with covalently immobilized Halotag fusion proteins constructed for CRC detection. Taken together, our results highlight the usefulness of the approach defined here to identify the TAAs specific to chronic diseases; they also demonstrate that the measurement of autoantibody levels in plasma against the TAAs identified here could be integrated into a point-of-care (POC) device for CRC detection with high diagnostic ability.
  • Item
    Copper(I)-Catalyzed Click Chemistry as a Tool for the Functionalization of Nanomaterials and the Preparation of Electrochemical (Bio)Sensors
    (Sensors, 2019) Yáñez Sedeño, Paloma; González Cortés, Araceli; Campuzano Ruiz, Susana; Pingarrón Carrazón, José Manuel
    Proper functionalization of electrode surfaces and/or nanomaterials plays a crucial role in the preparation of electrochemical (bio)sensors and their resulting performance. In this context, copper(I)-catalyzed azide-alkyne cycloaddition (CuAAC) has been demonstrated to be a powerful strategy due to the high yields achieved, absence of by-products and moderate conditions required both in aqueous medium and under physiological conditions. This particular chemistry offers great potential to functionalize a wide variety of electrode surfaces, nanomaterials, metallophthalocyanines (MPcs) and polymers, thus providing electrochemical platforms with improved electrocatalytic ability and allowing the stable, reproducible and functional integration of a wide range of nanomaterials and/or different biomolecules (enzymes, antibodies, nucleic acids and peptides). Considering the rapid progress in the field, and the potential of this technology, this review paper outlines the unique features imparted by this particular reaction in the development of electrochemical sensors through the discussion of representative examples of the methods mainly reported over the last five years. Special attention has been paid to electrochemical (bio)sensors prepared using nanomaterials and applied to the determination of relevant analytes at different molecular levels. Current challenges and future directions in this field are also briefly pointed out.
  • Item
    p53 and p63 Proteoforms Derived from Alternative Splicing Possess Differential Seroreactivity in Colorectal Cancer with Distinct Diagnostic Ability from the Canonical Proteins
    (Cancers, 2023) Montero Calle, Ana; Garranzo Asensio, María; Torrente Rodríguez, Rebeca Magnolia; Ruiz Valdepeñas Montiel, Víctor; Poves, Carmen; Dziakova, Jana; Sanz, Rodrigo; Díaz Del Arco, Cristina; Pingarrón Carrazón, José Manuel; Fernández Aceñero, María Jesús; Campuzano Ruiz, Susana; Barderas Manchado, Rodrigo
    Colorectal cancer (CRC) is the third most common cancer and the second most frequent cause of cancer-related death worldwide. The detection in plasma samples of autoantibodies against specific tumor-associated antigens has been demonstrated to be useful for the early diagnosis of CRC by liquid biopsy. However, new studies related to the humoral immune response in cancer are needed to enable blood-based diagnosis of the disease. Here, our aim was to characterize the humoral immune response associated with the different p53 and p63 proteoforms derived from alternative splicing and previously described as aberrantly expressed in CRC. Thus, here we investigated the diagnostic ability of the twelve p53 proteoforms and the eight p63 proteoforms described to date, and their specific N-terminal and C-terminal end peptides, by means of luminescence HaloTag beads immunoassays. Full-length proteoforms or specific peptides were cloned as HaloTag fusion proteins and their seroreactivity analyzed using plasma from CRC patients at stages I-IV (n = 31), individuals with premalignant lesions (n = 31), and healthy individuals (n = 48). p53γ, Δ40p53β, Δ40p53γ, Δ133p53γ, Δ160p53γ, TAp63α, TAp63δ, ΔNp63α, and ΔNp63δ, together with the specific C-terminal end α and δ p63 peptides, were found to be more seroreactive against plasma from CRC patients and/or individuals with premalignant lesions than from healthy individuals. In addition, ROC (receiver operating characteristic) curves revealed a high diagnostic ability of those p53 and p63 proteoforms to detect CRC and premalignant individuals (AUC higher than 85%). Finally, electrochemical biosensing platforms were employed in POC-like devices to investigate their usefulness for CRC detection using selected p53 and p63 proteoforms. Our results demonstrate not only the potential of these biosensors for the simultaneous analysis of proteoforms’ seroreactivity, but also their convenience and versatility for the clinical detection of CRC by liquid biopsy. In conclusion, we here show that p53 and p63 proteoforms possess differential seroreactivity in CRC patients in comparison to controls, distinctive from canonical proteins, which should improve the diagnostic panels for obtaining a blood-based biomarker signature for CRC detection.
  • Item
    Fullerenes in Electrochemical Catalytic and Affinity Biosensing: A Review
    (C: Journal of Carbon Research, 2017) Yáñez Sedeño, Paloma; Campuzano Ruiz, Susana; Pingarrón Carrazón, José Manuel
    Nanotechnology is becoming increasingly important in the field of (bio)sensors. The performance and sensitivity of electrochemical biosensors can be greatly improved by the integration of nanomaterials into their construction. In this sense, carbon nanomaterials have been widely used for preparation of biosensors due to their ability to enhance electron-transfer kinetics, high surface-to-volume ratios, and biocompatibility. Fullerenes are a very promising family of carbon nanomaterials and have attracted great interest in recent years in the design of novel biosensing systems due to fullerenes’ exceptional properties. These include multiple redox states, stability in many redox forms, easy functionalization and signal mediation. This paper outlines the state-of-the-art and future directions in the use and functionalization of fullerene-C60 and its derivatives, both as electrode modifiers and advanced labels in electrochemical catalytic and affinity biosensors through selected applications.
  • Item
    Magnetic Particles Coupled to Disposable Screen Printed Transducers for Electrochemical Biosensing
    (Sensors, 2016) Yáñez Sedeño, Paloma; Campuzano Ruiz, Susana; Pingarrón Carrazón, José Manuel
    Ultrasensitive biosensing is currently a growing demand that has led to the development of numerous strategies for signal amplification. In this context, the unique properties of magnetic particles; both of nano- and micro-size dimensions; have proved to be promising materials to be coupled with disposable electrodes for the design of cost-effective electrochemical affinity biosensing platforms. This review addresses, through discussion of selected examples, the way that nano- and micro-magnetic particles (MNPs and MMPs; respectively) have contributed significantly to the development of electrochemical affinity biosensors, including immuno-, DNA, aptamer and other affinity modes. Different aspects such as type of magnetic particles, assay formats, detection techniques, sensitivity, applicability and other relevant characteristics are discussed. Research opportunities and future development trends in this field are also considered.
  • Item
    Simultaneous Determination of the Main Peanut Allergens in Foods Using Disposable Amperometric Magnetic Beads-Based Immunosensing Platforms
    (Chemosensors, 2016) Ruiz Valdepeñas Montiel, Víctor; Torrente Rodríguez, Rebeca Magnolia; Campuzano Ruiz, Susana; Pellicanò, Alessandro; Reviejo García, Ángel Julio; Cosio, Maria; Pingarrón Carrazón, José Manuel
    In this work, a novel magnetic beads (MBs)-based immunosensing approach for the rapid and simultaneous determination of the main peanut allergenic proteins (Ara h 1 and Ara h 2) is reported. It involves the use of sandwich-type immunoassays using selective capture and detector antibodies and carboxylic acid-modified magnetic beads (HOOC-MBs). Amperometric detection at −0.20 V was performed using dual screen-printed carbon electrodes (SPdCEs) and the H2O2/hydroquinone (HQ) system. This methodology exhibits high sensitivity and selectivity for the target proteins providing detection limits of 18.0 and 0.07 ng/mL for Ara h 1 and Ara h 2, respectively, with an assay time of only 2 h. The usefulness of the approach was evaluated by detecting the endogenous content of both allergenic proteins in different food extracts as well as trace amounts of peanut allergen (0.0001% or 1.0 mg/kg) in wheat flour spiked samples. The developed platform provides better Low detection limits (LODs) in shorter assay times than those claimed for the allergen specific commercial ELISA kits using the same immunoreagents and quantitative information on individual food allergen levels. Moreover, the flexibility of the methodology makes it readily translate to the detection of other food-allergens.
  • Item
    Paving the Way for Reliable Alzheimer’s Disease Blood Diagnosis by Quadruple Electrochemical Immunosensing
    (ChemElectroChem, 2022) Valverde de la Fuente, Alejandro; Gordón Pidal, José María; Montero Calle, Ana; Arévalo Pérez, Beatriz; Serafín González-Carrato, Verónica; Calero, Miguel; Moreno Guzmán, María; López, Miguel Ángel; Escarpa, Alberto; Yáñez Sedeño, Paloma; Barderas, Rodrigo; Campuzano Ruiz, Susana; Pingarrón Carrazón, José Manuel
    Alzheimer’s disease (AD), the most common neurodegenerative disorder, demands new cost-effective and easy-to-use strategies for its reliable detection, mainly in the preclinical stages. Here, we report the first immunoplatform for the electrochemical multidetermination of four candidate protein biomarkers in blood, neurofilament light chain (NfL), Tau, phosphorylated Tau (p-Tau) and TAR DNA-Binding Protein 43 (TDP-43). It involves implementation of sandwich-type immunoassays and enzymatic labelling with horseradish peroxidase (HRP) on the surface of magnetic microbeads (MBs). Amperometric detection is performed after depositing the magnetic immunoconjugates on disposable quadruple transduction platforms by monitoring the enzymatic reduction of H2O2 mediated by hydroquinone (HQ). The immunoplatform achieved LOD values smaller than the content of target biomarkers in plasma of healthy subjects, with RSD values.