Person:
García Montero, María

Loading...
Profile Picture
First Name
María
Last Name
García Montero
Affiliation
Universidad Complutense de Madrid
Faculty / Institute
Óptica y Optometría
Department
Optometría y Visión
Area
Optica
Identifiers
UCM identifierScopus Author IDWeb of Science ResearcherIDDialnet IDGoogle Scholar ID

Search Results

Now showing 1 - 10 of 15
  • Item
    Randomized crossover trial of silicone hydrogel contact lenses
    (Contact Lens and Anterior Eye, 2018) García Montero, María; Rico del Viejo, Laura; Llorens Quintana, Clara; Lorente Velázquez, Amalia; Hernández Verdejo, José Luis; Madrid Costa, David
    Purpose: The aim of the current study is to assess, using new technologies, the interaction of four monthly silicone hydrogel contact lenses on the ocular surface and the comfort over 15 days of use. Methods: Prospective cross-over, randomized and double-masked study including four materials (lotrafilcon-B, samfilcon-A , comfilcon-A and filcom-V3). Clinical examination was performed in the following order: tear meniscus height, first break-up of the tear film, the average time of all tear film breakup incidents, bulbar redness, limbal redness (Keratograph 5M ,Oculus, Germany); central corneal thickness (Pentacam, Oculus, Germany), thermography values (FLIR A325; FLIR Systems Inc., USA), and slit-lamp evaluations, including ocular surface staining. Finally, subjective comfort was obtained from Contact Lens Dry Eye Questionnaire-8. Results: The impact of contact lens wear on the ocular surface didn’t show statistically significant changes over time except for corneal and conjunctival staining grades on day 15 compared to day 1 for the comfilcon A group (P = .003 and P = .01, respectively). Contact lens stability and impact on the ocular surface during contact lens wear didn’t show statistically significant changes over time except in the case of the comfilcon A material with respect to the irritation item (P = .01). Conclusions: These results suggest that the impact of monthly silicone hydrogel contact lens materials on the ocular surface after and during contact lens wear, contact lens stability over time, and subjective comfort did not reveal any significant changes over 15 days of use for any of the materials.
  • Item
    Effects of Blink Rate on Tear Film Optical Quality Dynamics with Different Soft Contact Lenses
    (Journal of Ophthalmology, 2019) García Montero, María; Rico del Viejo, Laura; Martínez Alberquilla, Irene; Hernández Verdejo, José Luis; Lorente Velázquez, Amalia; Madrid Costa, David
    Objective. The aim of this study was to investigate tear film optical quality dynamics for four types of silicone hydrogel contact lenses (SHCLs) for daily wear over a 15-day period and for different blink rate (BR) patterns. Methods. A prospective randomized, double-blind, cross-over pilot study including four SHCLs (A: lotrafilcon B (Air Optix plus HydraGlyde, Alcon Laboratories); B: samfilcon A (Ultra, Bausch & Lomb); C: comfilcon A (Biofinity, CooperVision); and D: filcom V3 (Blu:gen, Mark’Ennovy)). Serial measurements of Objective Scatter Index (OSI) using the HD Analyzer (Visiometrics S.L., Terrassa, Spain) were taken at different blinking patterns: blinking every 2.5 seconds (high BRs) and every 9 seconds (low BRs). They were performed during the first visit before CL insertion (baseline), after 20 minutes of CL wear (Day 1), and during the last visit after 8 hours of CL wear on day 15 of use (Day 15). Results. Normal young healthy subjects were recruited and fitted with the four lenses. For low BRs, the mean OSI value increased over time for all CLs and the slope of the curve also increased for all CLs, except for CL D. However, for high BRs, the mean OSI value increased only for CLs B and C and the slope of the curve did not change over time for any of them. Conclusions. These results suggest that the tear film optical quality dynamics after wearing SCHLs for 15 days seems to undergo a slight deterioration only for lowest BR.
  • Item
    Comparison of the impact of nesofilcon A hydrogel contact lens on the ocular surface and the comfort of presbyopic and non-presbyopic wearers
    (International journal of ophthalmology, 2019) Lorente Velázquez, Amalia; García Montero, María; Gómez Sanz, Fernando Javier; Rico del Viejo, Laura; Hernández Verdejo, José Luis; Madrid Costa, David
    AIM: To assess and compare the impact of a daily disposable contact lens (CL) with high water content on the ocular surface and comfort of the presbyopic and non-presbyopic population after one day of use. METHODS: Totally 20 presbyopes and 30 non-presbyopes non-contact wearers were fitted with nesofilcon A CLs. CL thickness was measured to assess material stability during daily wear, and ocular surface parameters were also assessed. Optical quality was analyzed for all cases. In addition, CL comfort was rated. RESULTS: No significant differences were found in CL thickness, tear film osmolarity, average tear break-up time, bulbar redness, central corneal thickness, corneal volume, root-mean-square of higher-order aberrations (RMS of HOAs) and vertical and horizontal coma, either as a function of the group or time of use. A significant decrease in tear meniscus height and first break-up of the tear film was found in the presbyopic group (P=0.038; P=0.007 respectively). A decrease in spherical aberration coefficient was found after CL insertion (P=0.031 monofocal CL; P=0.023 low addition multifocal CL; P=0.016 high addition multifocal CL). Multifocal CL were thicker than monofocal CL (P=0.045). Comparison between groups showed more discomfort in presbyopes than non-presbyopes (P=0.003). CONCLUSION: This study evidence that the behavior of the daily disposable CL with high water content seems to be stable during the day of use. Ocular parameters measured during wear show that CL behavior is the same for presbyopes and non-presbyopes, being more uncomfortable for presbyopes.
  • Item
    Repeatability of Noninvasive Keratograph 5M Measurements Associated With Contact Lens Wear
    (Eye & Contact lens, 2019) García Montero, María; Rico del Viejo, Laura; Lorente Velázquez, Amalia; Martínez Alberquilla, Irene; Hernández Verdejo, José Luis; Madrid Costa, David
    Objetive: To assess the intrarater repeatability of the measurements of tear meniscus height (TMH), noninvasive keratograph tear break-up time (NIKBUTs), and ocular redness measurements obtained with the Keratograph 5M (K5M) in a sample of soft silicone hydrogel contact lens (CL) wearers over 15 days. Methods: Prospective study over two consecutive weeks. Three measurements of TMH, NIKBUTs (NIKBUT first and NIKBUT average), and ocular redness were obtained in different sessions; the first day (baseline, at 8 hr of wear, and after lens removal) and the last day of wear-15th day (at 8 hr of wear and after lens removal). The repeatability of measurements were assessed by two intraclass correlation coefficient (ICC) forms; single measurement [ICC (2,1)] and multiple measurements (k=3) [ICC (2, k)]. Results: Sixty-four eyes were analyzed. The repeatability of baseline TMH [ICC (2,1) greater than 0.90; coefficient of repeatability (CR)=0.06 mm] and after and during CL wear [ICC (2,k) greater than 0.90; CR≤0.07 mm] were excellent. The repeatability of baseline NIKBUT average [ICC (2,k)=0.89 (0.82-0.93); CR=6.07 sec] was maintained after CL removal but was poorer during CL wear. The repeatability of baseline NIKBUT first [ICC (2,k) =0.80 (0.69-0.87); CR=8.74 sec] was maintained after CL removal and during CL wear at moderate-good level. Conclusions: Intrarater repeatability of TMH, NIKBUTs, and ocular redness performed by K5M after CL wear remains stable when three measurements are performed. However, intrarater repeatability during CL wear decreased only for NIKBUT average and was not affected by time of use (15 days).
  • Item
    Optical Behavior of an Enhanced Monofocal Intraocular Lens Compared with a Standard One
    (Applied Sciences, 2023) Albarrán Diego, César; García Montero, María; Garzón Jiménez, Nuria; González Fernández, Verónica; Gómez Pedrero, José Antonio
    The aim of this work was to compare an enhanced monofocal (RayOne EMV RAO200E, Rayner) and standard monofocal (RayOne RAO600C Aspheric, Rayner) intraocular lenses (IOLs) for three nominal powers (+10.00 D, +20.00 D and +30.00 D) as a function of the optical aperture diameter (pupil diameter) using a commercial Schlieren phase-shifting deflectometer NIMO TR1504 (Lambda-X, Belgium). From the wavefront maps measured by this instrument, the radial power profiles, the spherical aberration coefficients of the Zernike polynomial expansion (as a function of the optical aperture radius), and the root-mean-square (RMS) of the high-order aberrations (HOAs) were obtained and analyzed by comparing the two models. The results showed that the effective added power that could be obtained with the enhanced model depended directly on the pupil size and the power of the IOL implanted. The higher additions were achieved with the higher nominal IOL powers. The relationship between the pupil diameter, the corneal aberration of the patients and the power profile of these IOLs could have a crucial implication on the far distance and the final effective addition. However, it is important to note that these findings should be clinically validated through the implantation of these models in patients’ lenses.
  • Item
    Changes in Accommodative and Binocular Function following Phakic Intraocular Lens for High and Low-to-Moderate Myopia
    (International Journal of Environmental Research and Public Health, 2022) López Artero, Esther; Poyales Galán, Francisco; Garzón Jiménez, Nuria; Matamoros Hondarza, Alicia; Sáenz, Alba; Zhou, Ying; García Montero, María
    settingsOrder Article Reprints Open AccessArticle Changes in Accommodative and Binocular Function following Phakic Intraocular Lens for High and Low-to-Moderate Myopia by Esther López-Artero 1ORCID,Francisco Poyales 1,Nuria Garzón 1,2ORCID,Alicia Matamoros 1,Alba Sáez 1,Ying Zhou 3ORCID andMaría García-Montero 1,2,* 1 Miranza Group, C/Galileo 104, 28003 Madrid, Spain 2 Optometry and Vision Department, Faculty of Optics and Optometry, Complutense University of Madrid, 28037 Madrid, Spain 3 OCULUS Iberia, S.L., Tres Cantos, 28760 Madrid, Spain * Author to whom correspondence should be addressed. Int. J. Environ. Res. Public Health 2022, 19(11), 6716; https://doi.org/10.3390/ijerph19116716 Received: 27 April 2022 / Revised: 27 May 2022 / Accepted: 28 May 2022 / Published: 31 May 2022 Download Versions Notes Abstract The aim was to evaluate accommodative and binocular function of phakic intraocular lens implantable collamer lens (ICL) in high and low-to-moderate myopia. Prospective comparative cohort study with 38 myopic patients who underwent ICL implantation were divided into two groups of 19 patients, each one based on the spherical equivalent (SE): high-power (SE ≤ −6 D) and low-to-moderate (SE > −6 D). The push-up amplitude of accommodation (AA), monocular accommodative facility (MAF), distance and near ocular deviation, near convergence amplitude, near point convergence (NPC), stereopsis, and accommodative convergence/accommodation (AC/A) ratio were assessed before surgery and 1 week and 1 month postoperatively. The mean residual refractive error at 1 month after surgery improved in both groups, 0.18 ± 0.34 D and 0.09 ± 0.26 D, respectively (p < 0.001). There was a significant decrease in AA in both groups between preoperatively and at 1-week (p = 0.001; p = 0.008, respectively) and 1-month follow-up (p = 0.001; p = 0.008). For the rest of the binocular measurements, no statistically significant postoperative changes were found in any group. This finding suggests follow-up studies on amplitude of accommodation in phakic intraocular lens ICL implantation.
  • Item
    Intraocular lens power calculation in eyes with keratoconus
    (Journal of Cataract & Refractive Surgery, 2020) Garzón Jiménez, Nuria; Arriola Villalobos, Pedro; Felipe Márquez, Gema; Poyales Galán, Francisco; García Montero, María
    The purpose was to review and document the methods used to calculate the power of the intraocular lens (IOL) to be implanted in cataract surgery in the specific scenario of eyes with keratoconus (KC). This review was conducted of all scientific articles published in English that focused on the parameters and formulas used to calculate the power of the IOL to be implanted in eyes with KC undergoing cataract surgery. There are few publications that show in detail how IOL power is calculated in those particular cases. If the keratometric value is used based on the standard refractive index (1.3375), this results in a postoperative refractive error with a tendency to hyperopia. The SRK/T formula is the formula yielding the best outcomes. The greater the severity of KC, the greater the deviation of the postoperative refractive status deviation from the target outcome.
  • Item
    Design of an optical bench for polychromatic characterisation of advanced intraocular lens designs with spatial light modulator
    (2023) González Fernández, Verónica; Garzón Jiménez, Nuria; García Montero, María; Gómez Pedrero, José Antonio; Fernandez Nuñez, Sara; Albarrán Diego, César
    In recent years, the design of intraocular lenses (IOLs) has experienced a great deal of development and there is now a wide variety of designs. At the moment, some of the most interesting designs that allow for the greatest degree of innovation and customisation are lenses that combine a refractive part with a diffractive part
  • Item
    Impact of contact lens wear on NLRP3 gene expression: Implications for ocular frailty in middle-aged adults
    (Experimental Eye Research, 2020) Crooke Álvarez, Almudena; Martínez Alberquilla, Irene; García Montero, María; Rico Del Viejo, Laura; Ruiz Alcocer, Javier; Madrid Costa, David
    The inflammatory process plays a crucial role in frailty syndrome, which can appear in middle age and is associated with a poor health outcome. Consequently, gerontologists recommend screening inflammatory biomarkers in middle-aged adults to detect frailty and, therefore, prevent chronic diseases and mortality. External factors could be a risk factor for frailty because they can generate and extend the inflammatory process. For these reasons, we analysed the effect of long-term contact lens wear on mRNA level of genes linked to inflammation (IL-6, NLRP3, NK1R, CD73, MUC16 and TRPV1 genes) in conjunctival cells of middle-aged individuals, by quantitative PCR. Middle-aged contact lens wearers presented a significant increase of NLRP3 and MUC16 mRNA level as well as a decrease of CD73 mRNA level, in comparison with non-contact lens wearers. Additionally, we checked for a potential correlation between these transcript levels and clinical changes of the participants’ ocular surface. Unlike molecular analysis, clinical examination fails to detect inflammation in contact lens wearers. These data suggest that long-term contact lens wear could trigger an inflammatory response in middle age orchestrated by NLRP3 inflammasome and modulated by CD73 and MUC16 proteins. Further studies are needed to confirm our gene expression findings at the protein level as well as to investigate the potential role of long-term CL wear in the onset of ocular frailty.
  • Item
    Visual function, ocular surface integrity and symptomatology of a new extended depth-of-focus and a conventional multifocal contact lens
    (Contact Lens and Anterior Eye, 2020) Martínez Alberquilla, Irene; García Montero, María; Ruiz Alcocer, Javier; Crooke Álvarez, Almudena; Madrid Costa, David
    Purpose: To evaluate visual function, ocular surface integrity and dry eye symptoms with an extended depth-of-focus (EDOF) design and a conventional multifocal (MF) contact lens (CL) after 15 days of wear. Methods: A crossover single mask randomised clinical trial was conducted including 30 presbyopes who used an EDOF and a conventional MF CL (Biofinity MF) for 15 days each. Defocus curves, depth-of-focus range, contrast sensitivity (CS) under photopic and mesopic conditions (with and without glare) and subjective perception of halos and glare were evaluated. The ocular surface was evaluated through non-invasive Keratograph tear breakup time (NIKBUT), averaged tear breakup time (NIKBUT-avg), tear meniscus height (TMH), bulbar and limbal redness, and conjunctival and corneal staining. Dry eye symptoms were assessed with the OSDI questionnaire. Results: No statistically significant differences were found for defocus curves or depth-of-focus between the two CLs (both p > 0.05). Subjective perception of halos and glare was not significantly different between CLs. Statistically significant differences were observed for CS under mesopic conditions for low spatial frequencies (p = 0.008). None of the CL produced significant changes in NIKBUT, NIKBUT-avg, TMH or redness. No change in conjunctival staining was observed in 76.7 % and 73.3 % of participants for EDOF and Biofinity MF, respectively. No change in corneal staining was observed in 86.7 % and 83.3 % of participants for EDOF and Biofinity MF, respectively. No changes were observed in the symptomatology measured with OSDI questionnaire (p > 0.05). Conclusions: Both CL for presbyopia offer good visual quality, preserve the ocular surface integrity and provide the patient with similar symptomatology levels after 15 days of lens wear.