  • Item
    Riesgos personales producidos por LEDs utilizados en dispositivos de uso cotidiano
    (Seguridad y medio ambiente (Fundación MAPFRE), 2012) Chamorro Gutiérrez, Eva; Bonnin Arias, Cristina Natalia; Lobato Rincón, Luis Lucio; Navarro Valls, Juan José; Ramirez Mercado, Guillermo; Navarro Blanco, Carolina; Sánchez Ramos, Celia
    El uso de fuentes de iluminación LED (diodos emisores de luz) está creciendo de manera exponencial tanto en el campo de la iluminación ambiente como en dispositivos de uso personal y doméstico como smartphones, pantallas de ordenador, electrodomésticos, etc. Sin embargo, el principal problema que plantean los LEDs que emiten luz blanca radica en su alto contenido de radiaciones de la banda del azul, que son dañinas para el sistema visual. En este proyecto se ha diseñado un dispositivo de iluminación formado por diodos LED de diferentes características espectrales para comprobar si producen daño en la retina, sobre todo en células del epitelio pigmentario. Los experimentos han demostrado que la exposición a la luz aumenta el porcentaje de muerte celular inducida por la luz para todas las fuentes de luz LED, especialmente en las células expuestas a luz azul y blanca, en las que se produjo un aumento de la muerte celular respecto al control del 92% y 94% respectivamente. El estudio concluye que la exposición a altas intensidades de luz LED durante ciclos de luz/oscuridad produce daños en las células de la retina.
  • Item
    Valoración del espesor del ápex corneal con topógrafo de Scheimpflug: Repetibilidad de las medidas.
    (Gaceta de Optometría y óptica oftálmica, 2012) Bonnin Arias, Cristina Natalia; Chamorro Gutiérrez, Eva; Lobato Rincón, Luis Lucio; Sánchez Ramos, Celia
    Introducción. La medida del espesor corneal (EC) es un parámetro a tener en cuenta en la práctica óptico-oftalmológica, debido a su relación con otras variables de gran interés clínico. Existen distintos instrumentos, con diferentes bases físicas, que valoran el EC. Propósito. El objeto de este estudio fue evaluar la repetibilidad de las medidas de espesor corneal en el ápex, en personas de diferentes edades, obtenidas mediante un topógrafo de Scheimpflug. Material y métodos. La muestra estaba constituida por un total de 120 medidas del espesor del ápex corneal, 20 registros por cada una de las 6 personas seleccionadas, una por cada década de edad. Las medidas se realizaron con el topógrafo Pentacam. Resultados. Se calculó el coeficiente de variación de Pearson (CV) obteniendo, según las décadas, 1º=1,23; 2º=0,75; 3º=1,23; 4º=1.01; 5º=0.71; 6º=1.01. Conclusión. El instrumento también ha demostrado una adecuada repetibilidad para uso clínico de las medidas.
  • Item
    Changes in contrast sensitivity perception due to protector screens for welding tasks : conventional protective optical filter vs novel protective optical filter of selective absorbance
    (2012) Bonnin Arias, Cristina Natalia; Aguirre Vilacoro, V.; Chamorro Gutiérrez, E.; Lobato Rincón, Luis Lucio; Langa Moraga, Antonio; Navarro Valls, J.J.; Sánchez Ramos, Celia
    Purpose: To evaluate diff erences in contrast sensitivity perception in central visual field using protective optic fi lters for welding tasks. Two interposed filters are compared: a conventional protective optical fi lter and a new protective optical fi lter with selective absorption designed by University Complutense of Madrid (UCM). Methods: 36 people of working-age were included in a cross-sectional prospective observational study. Contrast sensitivity threshold in central visual fi eld was evaluated using FDT Perimeter, C-20 procedure (Humphrey systems, USA). ! ree conditions were set: a) without optical fi lters; b) with an interposition of conventional protective optical fi lter for welding (shade 2.5) and c) with an interposition of a novel protective optical fi lter of selective absorbance that fully blocks the short wavelength light and minimally attenuates the remaining bands of the visible spectrum. Results: Contrast sensitivity in all visual fi eld areas evaluated diminished 91-98% with the conventional protective optical fi lters. UCM optical fi lters provoked a low-level decrease in contrast sensitivity (9-19%). Mean contrast sensitivity thresholds were 29.5±5dB, 25.5±4dB, 1.8±2dB in conditions a, b and c respectively Conclusion: Conventional optical fi lters resulted in drastically diminished contrast sensitivity. UCM optical fi lter minimally diminish the visual function, allowing a suitable visibility and also maintaining an appropriate level of protection against phototoxic damage.
  • Item
    Mesopic pupil amplitude depending on the age and the wavelength of the stimuli.
    (2012) Lobato Rincón, Luis Lucio; Navarro Valls, J.J.; Navarro Blanco, Carolina; Bonnin Arias, Cristina Natalia; Ramirez Mercado, G.; Sánchez Ramos, Celia
    Purpose: In the present study, values of the phases of pupil light reflex were recorded and analyzed depending on the age, and the spectral content of the incident light, in order to determine changes on the pupil light reflex by means of various types of lights and compare their effects in every subsample and between them. Methods: The sample consists in 30 old subjects and 32 young subjects. To evaluate possible dementia in old subjects, the clock drawing test was applied. The pupillometer used was Power Refractor II, a binocular, infrared based instrument and autorefractometer. Four optical filters were interposed on the flash: a neutral density filter 05, and three interferential filters with peaks of transmission in 450 nm, 510 nm and 600 nm. Our team designed a parser programmed in java that calculates all the variables implicated. Results: In the old age group, the average amplitude were 1.23 ±0.3 mm, 1.03 ± 0.3mm, 1.11 ± 0.4 mm, and 0.85 ± 0.3 mm for white light, blue monochrome light, green monochrome light and red monochrome light, respectively. In the young age group, the average amplitude to white light was 2.29 ± 0.4 mm, and the average amplitude for blue, green and red monochrome lights were, respectively, 1.91 ± 0.3 mm, 2.04 ± 0.5mm, and 1.60 ± 0.6 mm. Both groups exhibited a similar behaviour when reactions were compared depending on the diff erent wavelength. Conclusion: Age affects considerably to mesopic pupil amplitudes values provoked for luminous stimuli. Likewise, blue and green monochrome lights bias the response in both groups.