Person:
Carballo Álvarez, Jesús

Loading...
Profile Picture
First Name
Jesús
Last Name
Carballo Álvarez
Affiliation
Universidad Complutense de Madrid
Faculty / Institute
Óptica y Optometría
Department
Optometría y Visión
Area
Optica
Identifiers
UCM identifierORCIDScopus Author IDWeb of Science ResearcherIDDialnet IDGoogle Scholar ID

Search Results

Now showing 1 - 6 of 6
  • Item
    Posterior cornea and thickness changes after scleral lens wear in keratoconus patients
    (Contact Lens and Anterior Eye, 2018) Serramito Blanco, María; Carpena Torres, Carlos; Carballo Álvarez, Jesús; Piñero, David Pablo; Lipson, Michael; Carracedo Rodríguez, Juan Gonzalo
    Purpose: To evaluate the changes in the corneal thickness, anterior chamber depth and posterior corneal curvature and aberrations after scleral lens wear in keratoconus patients with and without intrastromal corneal ring segments (ICRS). Methods:Twenty-six keratoconus subjects (36.95 ± 8.95 years) were evaluated after 8 h of scleral lens wear. The subjects were divided into two groups: those with ICRS (ICRS group) and without ICRS (KC group). The study variables evaluated before and immediately after scleral lens wear included corneal thickness evaluated in different quadrants, posterior corneal curvature at 2, 4, 6 and 8 mm of corneal diameter, posterior corneal aberrations for 4, 6 and 8 mm of pupil size and anterior chamber depth. Results: There was a statistically significant corneal thinning (p < 0.05) in the inferior region of the KC group and in the superior region of the ICRS group. No change (p > 0.05) in the anterior chamber depth was found. The KC group showed a steepening (p < 0.05) in the temporal quadrant and a flattening that mainly affected to the superior-nasal quadrant. The ICRS group showed a steepening (p < 0.05) that mainly affected to the superior-nasal quadrant. Regarding posterior corneal aberrations, only changes (p < 0.05) in Z4 for 8 mm and Z8 for 4 mm were found in the KC group. Conclusions: Short-term scleral lens wear showed a thinning of the cornea and changes in the posterior corneal curvature affects different regions in keratoconus patients with and without ICRS.
  • Item
    Project number: 238
    Herramientas audiovisuales online y protocolos en la formación, adaptación y gestión de lentes de contacto. Un modelo innovador en la Clínica Universitaria de Optometría de la UCM
    (2018) Carballo Álvarez, Jesús; Batres Valderas, Laura; Padrino Natividad, Esther; Rodríguez-Lafora Lorente, María; Serramito Blanco, María; Martín Prieto, Marina; Niño Rueda, Aranzazu; Niño Rueda, Cristina; Álvarez Rojas, David; Bartolomé Bartolomé, Gema; Peral Cerda, María Asunción; Carpena Torres, Carlos; Bella Gala, Rafael; Carracedo Rodríguez, Juan Gonzalo; González Blanco, Félix; García Alonso, Zoe Alexandra; Sánchez Pérez, María Isabel
    Con fines docentes y asistenciales, incluye Videos sobre manejo y limpieza de distintos tipos de lentes de contacto. Para la correcta formación de los estudiantes incluye varios manuales sobre el estudio ocular previo a la adaptación. Con fines asistenciales incorpora Material para acompañar la adaptación y entrega de las lentes de contacto. Para mejorar la gestión, incluye un Video-tutorial y los protocolos creados para los pedidos y gestión de las lentes de contacto.
  • Item
    Anterior Corneal Curvature and Aberration Changes After Scleral Lens Wear in Keratoconus Patients With and Without Ring Segments
    (Eye & Contact Lens: Science & Clinical Practice, 2019) Serramito Blanco, María; Carpena Torres, Carlos; Carballo Álvarez, Jesús; Piñero, David; Lipson, Michael; Carracedo Rodríguez, Juan Gonzalo
    Objective: To evaluate changes in the anterior corneal curvature and aberrometry after scleral contact lens wear in keratoconus (KC) subjects with and without intracorneal ring segments (ICRS). Methods: Twenty-six subjects diagnosed with keratoconus were selected to participate in the study. Subjects were divided into 2 groups, those with ICRS (KC-ICRS group) and those without ICRS (KC group). Subjects were instructed to wear 16.5-mm scleral lenses for 8 hours. Topographic and aberrometric parameters were evaluated before lens wear and immediately after lens removal. Anterior corneal curvature was evaluated at corneal diameters of 2, 4, 6, and 8 mm, and corneal aberrations were measured at 4-, 6-, and 8-mm pupil diameters. Results: The mean age of subjects was 36.95±8.95 years. In KC group, there was a statistically significant flattening of the central corneal curvature, from 6.98 to 7.09 mm (P<0.05). No changes were found in the central corneal curvature in the KC-ICRS group. The KC group showed anterior corneal curvature flattening, mainly in the nasal quadrant. The KC-ICRS group showed flattening primarily in the inferior hemisphere. In the KC group, spherical aberration for 6-mm pupil increased significantly. In the KC-ICRS group, changes in aberrations were significant for high-order root mean square at 4- and 6-mm pupil diameters (P<0.05), for oblique astigmatism for 4 mm and 6 mm, and for vertical coma for 4-mm pupil (P<0.05). Conclusion: Short-term scleral lens wear showed flattening of the anterior corneal surface in all subjects. In the KC group, the flattening was more pronounced in the nasal quadrant while changes were more pronounced inferiorly in KC-ICRS group.
  • Item
    PhDAY 2020 -FOO (Facultad de Óptica y Optometría)
    (2020) Pintor Just, Jesús Jerónimo; Carpena Torres, Carlos; Peral Cerda, María Asunción; Pérez de Lara, María Jesús; Toral, Fernando; Crooke Álvarez, Almudena; Pastrana Robles, Cristina; Carracedo Rodríguez, Juan Gonzalo; Cayuela López, Ana; Sorzano Sánchez, Óscar; Charbel, Carla; Garzón Jiménez, Nuria; Carballo Álvarez, Jesús; Diz Arias, Elena; Fernández Jiménez, Elena; Lledó Mayans, Victoria Eugenia; Gómez Pedrero, José Antonio; Durán Prieto, Elena; López Alonso, José Manuel; Fernández Torres, Miguel Ángel; Guzmán Aránguez, Ana Isabel; Gómez Manzanares, Ángela; Vázquez Molini, Daniel; Martínez Antón, Juan Carlos; Bernárdez Vilaboa, Ricardo; Mayorga Pinilla, Santiago; Álvarez Fernández-Balbuena, Antonio; Benítez, AntoJ.; Igalla El-Youssfi, Asmae; León Álvarez, Alejandro; Palomo Álvarez, Catalina; Awad Alkozi, Hanan; Sánchez Naves, Juan; Martínez Alberquilla, Irene; García Montero, María; Ruiz Alcocer, Javier; Madrid Costa, David; Martínez Florentín, Gema; Papas, Eric B.; Medrano Muñoz, Sandra Milena; Molina, Nancy; Jurado, Sandra; Oliveiros López, Juan; Platero Alvarado, Nadiuska Cristine; Garrido Mercado, Rafaela; Pérez Garmendia, Carlos; Antona Peñalba, Beatriz; Barrio De Santos, Ana Rosa; González Pérez, Mariano; Pérez Garmendia, Carlos; Serramito Blanco, María; Privado Aroco, Ana; Almalki, Wael; Bodas Romero, Julia; Ouzzani, Mohamed; Paune, Jaume; Calderón García, Raquel; Pitarch Velasco, Aída; Cebrián, José Luis; Sánchez Pérez, María Isabel; García Rojo, Marta María; Bonnin Arias, Cristina Natalia; Sánchez Ramos, Celia; Gutiérrez Jorrín, Sara Carmen; Rodríguez Alonso, Xabier; Laucirica Sáenz, Gorka; Arranz Márquez, Esther; Alonso Castellanos, Miriam; Teus Guezala, Miguel Ángel; Hernández Verdejo, José Luis; Mármol Errasti, Esther; Martín García, Beatriz; Arriola Villalobos, Pedro; Gómez De Liaño Sánchez, María Rosario; Mínguez Caro, N; Orduña Azcona, Javier; Navarro Gil, Francisco Javier; Huete Toral, Fernando; Rodríguez Pomar, Candela; Martínez Águila, Alejandro; Martín Gil, Alba; Tomé de la Torre, Miguel Ángel
    Por cuarto año consecutivo los doctorandos de la Facultad de Óptica y Optometría de la Universidad Complutense de Madrid cuentan con un congreso propio organizado por y para ellos, el 4º PhDAY- FOO. Se trata de un congreso gratuito abierto en la que estos jóvenes científicos podrán presentar sus investigaciones al resto de sus compañeros predoctorales y a toda la comunidad universitaria que quiera disfrutar de este evento. Apunta en tu agenda: el 15 de octubre de 2020. En esta ocasión será un Congreso On-line para evitar que la incertidumbre asociada a la pandemia Covid-19 pudiera condicionar su celebración.
  • Item
    Variation of Coma Aberration With Prismatic Soft Contact Lenses
    (Eye & Contact Lens, 2018) Carpena Torres, Carlos; López Alonso, José Manuel; Burgos Martínez, Mercedes; Carracedo Rodríguez, Juan Gonzalo; Carballo Álvarez, Jesús
    PURPOSE: To analyze the variation in vertical coma and the rest of ocular aberrations before and after fitting prismatic soft contact lenses (PSCL). METHODS: Thirty-seven eyes of 20 healthy subjects (24.30±2.03 years) were evaluated to analyze the variation in ocular wavefront aberrations before and after fitting PSCL of different base-down prism values (1.0, 1.5, and 2.0 prism diopters [PD]), designed to study its influence in the compensation of vertical coma aberration. A Hartmann-Shack sensor with a wavelength of 780 nm was used, considering a pupil size of 3 mm. In addition, the influence of PSCL in visual function under photopic conditions in terms of high-contrast visual acuity and contrast sensitivity was evaluated. RESULTS: There was statistically significant differences (P<0.05) in ocular aberrations from first to seventh order after fitting PSCL, but only the differences in vertical tilt, horizontal tilt, defocus, vertical astigmatism, and vertical coma were clinically relevant (Strehl ratio <0.8). The mean of vertical coma (μm) was 0.022±0.030 for control, 0.045±0.064 for 1.0 PD (P=0.645), 0.048±0.053 for 1.5 PD (P=0.037), and 0.074±0.047 for 2.0 PD (P<0.001). The changes in visual function under photopic conditions were not clinically relevant. CONCLUSIONS: PSCL induce a magnitude of vertical coma aberration directly proportional to prism value without affecting the rest of ocular high-order aberrations.
  • Item
    The effect of soft contact lens thickness in visual function after intracorneal ring segments surgery
    (Contact Lens and Anterior Eye, 2017) Carracedo Rodríguez, Juan Gonzalo; Canales Calvo, Javier; González Balboa, Paula; Recchioni, Alberto; Carpena Torres, Carlos; Carballo Álvarez, Jesús
    Objective: To study the influence of soft contact lens (SCL) central thickness and material in keratoconus on visual function after intracorneal ring segment (ICRS) surgery. Methods: A pilot, experimental, prospective, cross-sectional and double-blind study was performed. Fourteen keratoconus patients with age range of 34.75 ± 9.22 years (7 males and 7 females) with ICRS implanted were involved in the study. Two different SCL materials [Hioxifilcon A (G-5X/p-GMA/HEMA) and Lucifilcon A (silicone-hydrogel)] with four different central thicknesses (0.1, 0.2, 0.3 and 0.4 mm) were fitted in one eye per patient, selected randomly. High and low corrected distance visual acuity (CDVA) and contrast sensitivity (CS), corneal topography and corneal and total aberrometry were measured. Results: Corneal spherical like, coma like and root mean square (RMS) decreased significantly for 0.3 and 0.4 mm in both SCL materials (p < 0.05). Total RMS decreased significantly for 0.4 mm with both SCL materials (p < 0.05). High and low CDVA improved for 0.4 mm of thickness for both materials (p < 0.05). Statistically increasing were found in all thicknesses studied for CS in both materials (p < 0.05). Conclusion: A central thickness of the SCL equal or superior to 0.4 mm seems to decrease the ocular high order aberration (HOA) and to improve the visual function in keratoconus patients implanted with ICRS. However, the modulus of rigidity of the SCL would not influence the HOA correction.