Person:
Marco Martínez, Fernando

Loading...
Profile Picture
First Name
Fernando
Last Name
Marco Martínez
Affiliation
Universidad Complutense de Madrid
Faculty / Institute
Medicina
Department
Cirugía
Area
Traumatología y Ortopedia
Identifiers
UCM identifierScopus Author IDWeb of Science ResearcherIDDialnet ID

Search Results

Now showing 1 - 2 of 2
  • Item
    Do the humeral radiographic changes at 5-year follow-up affect the clinical outcomes of press-fit humeral stems in primary reverse shoulder arthroplasties?
    (European Journal of Orthopaedic Surgery & Traumatology, 2024) García Fernández, Carlos; Lópiz Morales, María Yaiza; Garríguez Pérez, Daniel; Arvinius, Camilla; Ponz, Virginia; Echevarria, Marta; Garrido, Ana; Marco Martínez, Fernando
    Introduction: The purposes of this study were to analyze and compare the functional outcomes and radiological changes around the press-fit humeral components in two contemporary medialized reverse total shoulder arthroplasty (RTSA) systems at a minimum of 5-year follow-up. Materials and methods: Between December 2003 and December 2015, 249 consecutive RTSAs were performed at our hospital. Of these, 68 primary uncemented RTSA met our inclusion criteria. The Constant-Murley score (CMS), the modified Constant score, a visual analog scale (VAS) and active shoulder range of motion (ROM) were measured pre- and postoperatively. Radiological assessment was performed by plain radiographs at a minimum of 5 years postoperatively. Results: At a mean follow-up of 80.2 months, there was no significant difference (p = .59) between the postoperative functional scores and range of motion of the two groups (Delta Xtend and Lima SMR). Radiological data of stress-shielding were observed in 38 patients (55.9%) being slightly more frequent in the Lima SMR group (21 patients) than in the Delta Xtend group (17 patients) (p = .62). Conclusions: Our study shows that the good functional results are similar between the two uncemented RTSA systems used and that they do not depend on the presence of radiological changes (stress-shielding) in the humeral stem at a minimum 5-year follow-up.
  • Item
    Does fluoroscopy improve baseplate position compared to conventional technique in reverse shoulder arthroplasty? A preliminary study
    (Shoulder and Elbow, 2021) Galán Olleros, María; Lópiz Morales, María Yaiza; Ciller, Gabriel; Alcobía Díaz, Borja; García Fernández, Carlos; Marco Martínez, Fernando
    Background: Accurate placement of glenoid component in reverse shoulder arthroplasty remains a challenge for surgeons of all levels of expertise; however, no studies have evaluated the utility of fluoroscopy as a surgical assistance method. Methods: Prospective comparative study of 33 patients undergoing primary reverse shoulder arthroplasty during a 12-month period. Fifteen patients had a baseplate placed using the conventional "free hand" technique (control group), and 18 patients using intraoperative fluoroscopy assistance group, in a case-control design. Postoperative glenoid position was evaluated on postoperative Computed Tomography (CT) scan. Results: The mean deviation of version and inclination for fluoroscopy assistance vs. control group was 1.75° (0.675-3.125) vs. 4.2° (1.975-10.45) (p = .015), and 3.85° (0-7.225) vs. 10.35° (4.35-18.75) (p = .009). The distance from the central peg midpoint to the inferior glenoid rim (fluoroscopy assistance 14.61 mm/control 4.75 mm, p = .581) and the surgical time (fluoroscopy assistance 1.93 ± 0.57/control 2.18 ± 0.44 h, p = .400) showed no differences, with an average radiation dose of 0.45 mGy and fluoroscopy time of 14 s. Conclusions: Accurate axial and coronal scapular plane positioning of glenoid component is improved with intraoperative fluoroscopy at the cost of a greater radiation dose and without differences in surgical time. Comparative studies are needed to determine whether their use in relation to more expensive surgical assistance systems result in similar effectiveness.L evel of evidence : Level III, therapeutic study.