Person:
Ruiz Valdepeñas Montiel, Víctor

Loading...
Profile Picture
First Name
Víctor
Last Name
Ruiz Valdepeñas Montiel
Affiliation
Universidad Complutense de Madrid
Faculty / Institute
Ciencias Químicas
Department
Química en Ciencias Farmacéuticas
Area
Identifiers
UCM identifierORCIDScopus Author IDDialnet ID

Search Results

Now showing 1 - 10 of 19
  • Item
    Amperometric Immunosensing Scaffolds for Rapid, Simple, Non-Invasive and Accurate Determination of Protein Biomarkers of Well-Accepted and Emerging Clinical Importance
    (Proceedings, 2017) Pedrero Muñoz, María; Muñoz San Martín, Cristina; Torrente Rodríguez, Rebeca Magnolia; Ruiz Valdepeñas Montiel, Víctor; Vargas Orgaz, Eva; Manuel de Villena Rueda, Francisco Javier; Barderas Manchado, Rodrigo; Campuzano Ruiz, Susana; Pingarrón Carrazón, José Manuel
  • Item
    Toward Liquid Biopsy: Determination of the Humoral Immune Response in Cancer Patients Using HaloTag Fusion Protein-Modified Electrochemical Bioplatforms
    (Analytical Chemistry, 2016) Garranzo Asensio, María; Guzmán Aránguez, Ana Isabel; Povés Francés, Carmen; Fernández Aceñero, Mª Jesús; Torrente Rodríguez, Rebeca Magnolia; Ruiz Valdepeñas Montiel, Víctor; Domínguez Muñóz, Gemma; San Frutos Llorente, Luis; Rodríguez Salas, Nuria; Villalba Díaz, Mayte; Pingarrón Carrazón, José Manuel; Campuzano Ruiz, Susana; Barderas Manchado, Rodrigo
    Autoantibodies raised against tumor-associated antigens have shown high promise as clinical biomarkers for reliable diagnosis, prognosis, and therapy monitoring of cancer. An electrochemical disposable biosensor for the specific and sensitive determination of p53-specific autoantibodies has been developed for the first time in this work. This biosensor involves the use of magnetic microcarriers (MBs) modified with covalently immobilized HaloTag fusion p53 protein as solid supports for the selective capture of specific autoantibodies. After magnetic capture of the modified MBs onto screen-printed carbon working electrodes, the amperometric signal using the system hydroquinone/H2O2 was related to the levels of p53-autoantibodies in the sample. The biosensor was applied for the analysis of sera from 24 patients with high-risk of developing colorectal cancer and 6 from patients already diagnosed with colorectal (4) and ovarian (2) cancer. The developed biosensor was able to determine p53 autoantibodies with a sensitivity higher than that of a commercial standard ELISA using a just-in-time produced protein in a simpler protocol with less sample volume and easily miniaturized and cost-effective instrumentation.
  • Item
    p53 and p63 Proteoforms Derived from Alternative Splicing Possess Differential Seroreactivity in Colorectal Cancer with Distinct Diagnostic Ability from the Canonical Proteins
    (Cancers, 2023) Montero Calle, Ana; Garranzo Asensio, María; Torrente Rodríguez, Rebeca Magnolia; Ruiz Valdepeñas Montiel, Víctor; Poves, Carmen; Dziakova, Jana; Sanz, Rodrigo; Díaz Del Arco, Cristina; Pingarrón Carrazón, José Manuel; Fernández Aceñero, María Jesús; Campuzano Ruiz, Susana; Barderas Manchado, Rodrigo
    Colorectal cancer (CRC) is the third most common cancer and the second most frequent cause of cancer-related death worldwide. The detection in plasma samples of autoantibodies against specific tumor-associated antigens has been demonstrated to be useful for the early diagnosis of CRC by liquid biopsy. However, new studies related to the humoral immune response in cancer are needed to enable blood-based diagnosis of the disease. Here, our aim was to characterize the humoral immune response associated with the different p53 and p63 proteoforms derived from alternative splicing and previously described as aberrantly expressed in CRC. Thus, here we investigated the diagnostic ability of the twelve p53 proteoforms and the eight p63 proteoforms described to date, and their specific N-terminal and C-terminal end peptides, by means of luminescence HaloTag beads immunoassays. Full-length proteoforms or specific peptides were cloned as HaloTag fusion proteins and their seroreactivity analyzed using plasma from CRC patients at stages I-IV (n = 31), individuals with premalignant lesions (n = 31), and healthy individuals (n = 48). p53γ, Δ40p53β, Δ40p53γ, Δ133p53γ, Δ160p53γ, TAp63α, TAp63δ, ΔNp63α, and ΔNp63δ, together with the specific C-terminal end α and δ p63 peptides, were found to be more seroreactive against plasma from CRC patients and/or individuals with premalignant lesions than from healthy individuals. In addition, ROC (receiver operating characteristic) curves revealed a high diagnostic ability of those p53 and p63 proteoforms to detect CRC and premalignant individuals (AUC higher than 85%). Finally, electrochemical biosensing platforms were employed in POC-like devices to investigate their usefulness for CRC detection using selected p53 and p63 proteoforms. Our results demonstrate not only the potential of these biosensors for the simultaneous analysis of proteoforms’ seroreactivity, but also their convenience and versatility for the clinical detection of CRC by liquid biopsy. In conclusion, we here show that p53 and p63 proteoforms possess differential seroreactivity in CRC patients in comparison to controls, distinctive from canonical proteins, which should improve the diagnostic panels for obtaining a blood-based biomarker signature for CRC detection.
  • Item
    Simultaneous Determination of the Main Peanut Allergens in Foods Using Disposable Amperometric Magnetic Beads-Based Immunosensing Platforms
    (Chemosensors, 2016) Ruiz Valdepeñas Montiel, Víctor; Torrente Rodríguez, Rebeca Magnolia; Campuzano Ruiz, Susana; Pellicanò, Alessandro; Reviejo García, Ángel Julio; Cosio, Maria; Pingarrón Carrazón, José Manuel
    In this work, a novel magnetic beads (MBs)-based immunosensing approach for the rapid and simultaneous determination of the main peanut allergenic proteins (Ara h 1 and Ara h 2) is reported. It involves the use of sandwich-type immunoassays using selective capture and detector antibodies and carboxylic acid-modified magnetic beads (HOOC-MBs). Amperometric detection at −0.20 V was performed using dual screen-printed carbon electrodes (SPdCEs) and the H2O2/hydroquinone (HQ) system. This methodology exhibits high sensitivity and selectivity for the target proteins providing detection limits of 18.0 and 0.07 ng/mL for Ara h 1 and Ara h 2, respectively, with an assay time of only 2 h. The usefulness of the approach was evaluated by detecting the endogenous content of both allergenic proteins in different food extracts as well as trace amounts of peanut allergen (0.0001% or 1.0 mg/kg) in wheat flour spiked samples. The developed platform provides better Low detection limits (LODs) in shorter assay times than those claimed for the allergen specific commercial ELISA kits using the same immunoreagents and quantitative information on individual food allergen levels. Moreover, the flexibility of the methodology makes it readily translate to the detection of other food-allergens.
  • Item
    Magnetic Beads-Based Sensor with Tailored Sensitivity for Rapid and Single-Step Amperometric Determination of miRNAs
    (International Journal of Molecular Sciences, 2017) Vargas Orgaz, Eva; Torrente Rodríguez, Rebeca Magnolia; Ruiz Valdepeñas Montiel, Víctor; Povedano Muñumel, Eloy; Pedrero Muñoz, María; Montoya, Juan; Campuzano Ruiz, Susana; Pingarrón Carrazón, José Manuel
    This work describes a sensitive amperometric magneto-biosensor for single-step and rapid determination of microRNAs (miRNAs). The developed strategy involves the use of direct hybridization of the target miRNA (miRNA-21) with a specific biotinylated DNA probe immobilized on streptavidin-modified magnetic beads (MBs), and labeling of the resulting heteroduplexes with a specific DNA–RNA antibody and the bacterial protein A (ProtA) conjugated with an horseradish peroxidase (HRP) homopolymer (Poly-HRP40) as an enzymatic label for signal amplification. Amperometric detection is performed upon magnetic capture of the modified MBs onto the working electrode surface of disposable screen-printed carbon electrodes (SPCEs) using the H2O2/hydroquinone (HQ) system. The magnitude of the cathodic signal obtained at −0.20 V (vs. the Ag pseudo-reference electrode) demonstrated linear dependence with the concentration of the synthetic target miRNA over the 1.0 to 100 pM range. The method provided a detection limit (LOD) of 10 attomoles (in a 25 μL sample) without any target miRNA amplification in just 30 min (once the DNA capture probe-MBs were prepared). This approach shows improved sensitivity compared with that of biosensors constructed with the same anti-DNA–RNA Ab as capture instead of a detector antibody and further labeling with a Strep-HRP conjugate instead of the Poly-HRP40 homopolymer. The developed strategy involves a single step working protocol, as well as the possibility to tailor the sensitivity by enlarging the length of the DNA/miRNA heteroduplexes using additional probes and/or performing the labelling with ProtA conjugated with homopolymers prepared with different numbers of HRP molecules. The practical usefulness was demonstrated by determination of the endogenous levels of the mature target miRNA in 250 ng raw total RNA (RNAt) extracted from human mammary epithelial normal (MCF-10A) and cancer (MCF-7) cells and tumor tissues.
  • Item
    Disposable electrochemical immunoplatform to shed light on the role of the multifunctional glycoprotein TIM-1 in cancer cells invasion
    (Talanta, 2024) Quinchia, Jennifer; Blázquez-García, Marina; Torrente Rodríguez, Rebeca Magnolia; Ruiz Valdepeñas Montiel, Víctor; Serafín González-Carrato, Verónica; Rejas-González, Raquel; Montero-Calle, Ana; Orozco, Jahir; Pingarrón Carrazón, José Manuel; Barderas Manchado, Rodrigo; Campuzano Ruiz, Susana
    Detecting overexpression of cancer biomarkers is an excellent tool for diagnostic/prognostic and follow-up of patients with cancer or their response to treatment. This work illustrates the relevance of interrogating the levels of T-cell immunoglobulin and mucin domain 1 (TIM-1) protein as a diagnostic/prognostic biomarker of high-prevalence breast and lung cancers by using an amperometric disposable magnetic microparticles-assisted immunoplatform. The developed method integrates the inherent advantages of carboxylic acid-functionalized magnetic beads (HOOC-MBs) as pre-concentrator support and the amperometric transduction at screen-printed carbon electrodes (SPCEs). The immunoplatform involves a sandwich-type immunoassay assembled on HOOC-MBs through the specific capture/labeling of TIM-1 using capture antibodies and horseradish peroxidase (HRP)-conjugated biotinylated detection antibodies as biorecognition elements. The magnetic immunoconjugates were confined onto the working electrode (WE) surface of the SPCEs for amperometric detection using the hydroquinone/hydrogen peroxide/HRP (HQ/H2O2/HRP) redox system. The method allows the selective detection of TIM-1 protein over the 87–7500 pg mL−1 concentration range in only 45 min, with a limit of detection of 26 pg mL−1. The developed bioplatform was successfully applied to the analysis of breast and lung cancer cell extracts, providing the first quantitative results of the target glycoprotein in these types of samples.
  • Item
    Improving Cancer Outcomes through Electrochemical Biosensing of Early Diagnosis/Prognosis Biomarkers in Human Biopsies
    (Proceedings, 2017) Pingarrón Carrazón, José Manuel; Campuzano Ruiz, Susana; Torrente Rodríguez, Rebeca Magnolia; Ruiz Valdepeñas Montiel, Víctor; Vargas Orgaz, Eva; Barderas Manchado, Rodrigo
  • Item
    Single-Step Incubation Determination of miRNAs in Cancer Cells Using an Amperometric Biosensor Based on Competitive Hybridization onto Magnetic Beads
    (Sensors, 2018) Vargas Orgaz, Eva; Povedano Muñumel, Eloy; Ruiz Valdepeñas Montiel, Víctor; Torrente Rodríguez, Rebeca Magnolia; Zouari, Mohamed; Montoya Miñano, Juan José; Raouafi, Noureddine; Campuzano Ruiz, Susana; Pingarrón Carrazón, José Manuel
    This work reports an amperometric biosensor for the determination of miRNA-21, a relevant oncogene. The methodology involves a competitive DNA-target miRNA hybridization assay performed on the surface of magnetic microbeads (MBs) and amperometric transduction at screen-printed carbon electrodes (SPCEs). The target miRNA competes with a synthetic fluorescein isothiocyanate (FITC)-modified miRNA with an identical sequence for hybridization with a biotinylated and complementary DNA probe (b-Cp) immobilized on the surface of streptavidin-modified MBs (b-Cp-MBs). Upon labeling, the FITC-modified miRNA attached to the MBs with horseradish peroxidase (HRP)-conjugated anti-FITC Fab fragments and magnetic capturing of the MBs onto the working electrode surface of SPCEs. The cathodic current measured at −0.20 V (versus the Ag pseudo-reference electrode) was demonstrated to be inversely proportional to the concentration of the target miRNA. This convenient biosensing method provided a linear range between 0.7 and 10.0 nM and a limit of detection (LOD) of 0.2 nM (5 fmol in 25 μL of sample) for the synthetic target miRNA without any amplification step. An acceptable selectivity towards single-base mismatched oligonucleotides, a high storage stability of the b-Cp-MBs, and usefulness for the accurate determination of miRNA-21 in raw total RNA (RNAt) extracted from breast cancer cells (MCF-7) were demonstrated.
  • Item
    Project number: PIMCD320/23-24
    Contribuyendo a la internacionalización de la docencia práctica inclusiva y sostenible en Química Analítica
    (0024) Gamella Carballo, María; Pedrero Muñoz, María; Campuzano Ruiz, Susana; Serafín González-Carrato, Verónica; Torrente Rodríguez, Rebeca Magnolia; Ruiz Valdepeñas Montiel, Víctor; Valverde De La Fuente, Alejandro; Povedano Muñumel, Eloy; Muñoz San Martín, Cristina; Pérez Ginés, Víctor; Blázquez García, Marina; Tejerina Miranda, Sandra; de Valle Ávila, Marcos; Molla Escudero, David
  • Item
    Multiplexed magnetic beads-assisted amperometric bioplatforms for global detection of methylations in nucleic acids
    (Analytica Chimica Acta, 2021) Povedano Muñumel, Eloy; Gamella Carballo, María; Torrente Rodríguez, Rebeca Magnolia; Ruiz Valdepeñas Montiel, Víctor; Montero-Calle, Ana; Solís-Fernández, Guillermo; Navarro Villoslada, Fernando; Pedrero, María; Peláez-García, Alberto; Mendiola, Marta; Hardisson, David; Feliú, Jaime; Barderas, Rodrigo; Pedrero Muñoz, María; Pingarrón Carrazón, José Manuel
    This work reports the first electrochemical bioplatform developed for the multidetection of 5-methylcytosine (5-mC) and 5-hydroxymethylcytosine (5-hmC) in DNA, DNA N6-methyladenine (6mA) and RNA N6-methyladenosine (m6A) methylations at global level. Direct competitive immunoassays were implemented on the surface of magnetic beads (MBs) and optimized for the single amperometric determination of different targets varying in length, sequence and number of methylations on screenprinted carbon electrodes. After evaluating the sensitivity and selectivity of such determinations and the confirmation of no cross-reactivity, a multiplexed disposable platform allowing the simultaneous determination of the mentioned four methylation events in only 45 min has been prepared. The multiplexed bioplatform was successfully applied to the determination of m6A in cellular total RNA and of 5-mC, 5-hmC and 6mA in genomic DNA extracted from tissues. The developed bioplatform showed its usefulness to discriminate the aggressiveness of cancerous cells and between healthy and tumor tissues of colorectal cancer patients.