Person:
Pastrana Robles, Cristina

Loading...
Profile Picture
First Name
Cristina
Last Name
Pastrana Robles
Affiliation
Universidad Complutense de Madrid
Faculty / Institute
Óptica y Optometría
Department
Optometría y Visión
Area
Optica
Identifiers
UCM identifierORCIDScopus Author IDWeb of Science ResearcherIDDialnet ID

Search Results

Now showing 1 - 7 of 7
  • Item
    Accuracy and precision of automated subjective refraction in young hyperopes under cycloplegia
    (Journal of Optometry, 2023) Carracedo Rodríguez, Juan Gonzalo; Carpena Torres, Carlos; Pastrana Robles, Cristina; Rodríguez -Lafora Lorente, María; Serramito Blanco, María; Privado Aroco, Ana; Espinosa Vidal, Teresa M.
    Purpose: To assess the agreement between the Eye Refract, an instrument to perform subjective automated refraction, and the traditional subjective refraction, as the gold standard, in young hyperopes under noncycloplegic and cycloplegic conditions. Methods: A cross-section and randomized study was carried out, involving 42 participants (18.2 ± 7.7 years, range 6 to 31 years). Only one eye was chosen for the analysis, randomly. An optometrist conducted the refraction with the Eye Refract, while another different optometrist conducted the traditional subjective refraction. Spherical equivalent (M), cylindrical components (J0 and J45), and corrected distance visual acuity (CDVA) were compared between both refraction methods under noncycloplegic and cycloplegic conditions. A Bland-Altman analysis was performed to assess the agreement (accuracy and precision) between both refraction methods. Results: Without cycloplegia, the Eye Refract showed significantly lower values of hyperopia than the traditional subjective refraction (p < 0.009), the mean difference (accuracy) and its 95% limits of agreement (precision) being -0.31 (+0.85, -1.47) D. Conversely, there were no statistical differences between both refraction methods under cycloplegic conditions (p ≥ 0.05). Regarding J0 and J45, both refraction methods manifested no significant differences between them under noncycloplegic and cycloplegic conditions (p ≥ 0.05). Finally, the Eye Refract significantly improved CDVA (0.04 ± 0.01 logMAR) compared with the traditional subjective refraction without cycloplegia (p = 0.01). Conclusions: The Eye Refract is presented as a useful instrument to determine the refractive error in young hyperopes, the use of cycloplegia being necessary to obtain accurate and precise spherical refraction.
  • Item
    A Comparison between Automated Subjective Refraction and Traditional Subjective Refraction in Keratoconus Patients
    (Optometry and Vision Science, 2021) Carracedo Rodríguez, Juan Gonzalo; Carpena Torres, Carlos; Pastrana Robles, Cristina; Privado Aroco, Ana; Serramito Blanco, María; Espinosa Vidal, Teresa M.; Rodríguez-Lafora Lorente, María
    SIGNIFICANCE: The performance of the Eye Refract (Luneau Technology, Chartres, France), a new instrument to perform aberrometry-based automated subjective refraction, has been previously evaluated in healthy subjects. However, its clinical implications in other ocular conditions are still unknown. PURPOSE: The purpose of this study was to evaluate the agreement between the Eye Refract and the traditional subjective refraction, as the criterion standard, in keratoconus patients with and without intracorneal ring segments (ICRSs). METHODS: A total of 50 eyes of 50 keratoconus patients were evaluated, dividing the sample into 2 groups: 27 eyes without ICRS (37.78 ± 9.35 years) and 23 eyes with ICRS (39.26 ± 13.62 years). An optometrist conducted the refraction with the Eye Refract, and another different optometrist conducted the traditional subjective refraction on the same day. Spherical equivalent (M), cylindrical vectors (J0 and J45), and corrected distance visual acuity were compared between both methods of refraction. In addition, Bland-Altman analysis was performed to assess the agreement between both methods of refraction. RESULTS: There were no statistically significant differences (P ≥ .05) between the Eye Refract and the traditional subjective refraction for all the variables under study in either group. Without ICRS, the mean difference and 95% limits of agreement (upper, lower) were −0.20 (+1.50, −1.89) D for M, −0.14 (+1.40, −1.68) D for J0, and +0.05 (+1.23, −1.14) D for J45. With ICRS, these values worsened to −0.62 (+3.89, −5.12) D for M, +0.06 (+2.46, −2.34) D for J0, and −0.02 (+2.23, −2.28) D for J45. CONCLUSIONS: The Eye Refract seems to offer similar results compared with the traditional subjective refraction in keratoconus patients not implanted with ICRS. However, some patients could show abnormal measurements, especially those with ICRS, who should be treated with caution in clinical practice.
  • Item
    PhDAY 2020 -FOO (Facultad de Óptica y Optometría)
    (2020) Pintor Just, Jesús Jerónimo; Carpena Torres, Carlos; Peral Cerda, María Asunción; Pérez de Lara, María Jesús; Toral, Fernando; Crooke Álvarez, Almudena; Pastrana Robles, Cristina; Carracedo Rodríguez, Juan Gonzalo; Cayuela López, Ana; Sorzano Sánchez, Óscar; Charbel, Carla; Garzón Jiménez, Nuria; Carballo Álvarez, Jesús; Diz Arias, Elena; Fernández Jiménez, Elena; Lledó Mayans, Victoria Eugenia; Gómez Pedrero, José Antonio; Durán Prieto, Elena; López Alonso, José Manuel; Fernández Torres, Miguel Ángel; Guzmán Aránguez, Ana Isabel; Gómez Manzanares, Ángela; Vázquez Molini, Daniel; Martínez Antón, Juan Carlos; Bernárdez Vilaboa, Ricardo; Mayorga Pinilla, Santiago; Álvarez Fernández-Balbuena, Antonio; Benítez, AntoJ.; Igalla El-Youssfi, Asmae; León Álvarez, Alejandro; Palomo Álvarez, Catalina; Awad Alkozi, Hanan; Sánchez Naves, Juan; Martínez Alberquilla, Irene; García Montero, María; Ruiz Alcocer, Javier; Madrid Costa, David; Martínez Florentín, Gema; Papas, Eric B.; Medrano Muñoz, Sandra Milena; Molina, Nancy; Jurado, Sandra; Oliveiros López, Juan; Platero Alvarado, Nadiuska Cristine; Garrido Mercado, Rafaela; Pérez Garmendia, Carlos; Antona Peñalba, Beatriz; Barrio De Santos, Ana Rosa; González Pérez, Mariano; Pérez Garmendia, Carlos; Serramito Blanco, María; Privado Aroco, Ana; Almalki, Wael; Bodas Romero, Julia; Ouzzani, Mohamed; Paune, Jaume; Calderón García, Raquel; Pitarch Velasco, Aída; Cebrián, José Luis; Sánchez Pérez, María Isabel; García Rojo, Marta María; Bonnin Arias, Cristina Natalia; Sánchez Ramos, Celia; Gutiérrez Jorrín, Sara Carmen; Rodríguez Alonso, Xabier; Laucirica Sáenz, Gorka; Arranz Márquez, Esther; Alonso Castellanos, Miriam; Teus Guezala, Miguel Ángel; Hernández Verdejo, José Luis; Mármol Errasti, Esther; Martín García, Beatriz; Arriola Villalobos, Pedro; Gómez De Liaño Sánchez, María Rosario; Mínguez Caro, N; Orduña Azcona, Javier; Navarro Gil, Francisco Javier; Huete Toral, Fernando; Rodríguez Pomar, Candela; Martínez Águila, Alejandro; Martín Gil, Alba; Tomé de la Torre, Miguel Ángel
    Por cuarto año consecutivo los doctorandos de la Facultad de Óptica y Optometría de la Universidad Complutense de Madrid cuentan con un congreso propio organizado por y para ellos, el 4º PhDAY- FOO. Se trata de un congreso gratuito abierto en la que estos jóvenes científicos podrán presentar sus investigaciones al resto de sus compañeros predoctorales y a toda la comunidad universitaria que quiera disfrutar de este evento. Apunta en tu agenda: el 15 de octubre de 2020. En esta ocasión será un Congreso On-line para evitar que la incertidumbre asociada a la pandemia Covid-19 pudiera condicionar su celebración.
  • Item
    Changes in visual quality with soft contact lenses after the instillation of hyaluronic acid eye drops
    (Contact Lens & Anterior Eye, 2021) Carpena Torres, Carlos; Pastrana Robles, Cristina; Rodríguez Pomar, Candela; Serramito Blanco, María; Batres Valderas, Laura; Carracedo Rodríguez, Juan Gonzalo
    Purpose: To evaluate the changes in visual function and anterior surface aberrations during soft contact lens (SCL) wear after the instillation of hyaluronic acid (HA) eye drops with different viscosity. Methods: A prospective, randomized, and participant-masked study was performed. Twenty healthy participants (25.4 ± 2.6 years) were evaluated. Hydrogel (Ocufilcon D) and silicone-hydrogel (Somofilcon A) SCL were randomly assigned to both eyes of the same participant. Visual function in terms of high- and low-contrast corrected distance visual acuity (CDVA) and anterior contact lens surface aberrations (RMS HOA) were measured before and after the instillation, at different times, of different eye drops: saline (control) and 0.1%, 0.2%, and 0.3% HA. Results: Compared with the saline solution, during hydrogel SCL wear, there was an improvement (P < 0.05) in high-contrast CDVA after 3 and 10 min with 0.1% HA, and after 5 and 20 min with 0.2% HA. During silicone�hydrogel SCL wear, there was a deterioration (P < 0.05) in high-contrast CDVA after 1 and 30 min with 0.3% HA. Additionally, during silicone-hydrogel SCL wear, there was also a deterioration (P < 0.05) in low-contrast CDVA after 5 and 20 min with 0.3% HA. In terms of RMS HOA, there were no clinically relevant changes with both SCL. Conclusions: The instillation of HA eye drops could have a different effect on visual quality depending on their concentration of HA, the contact lens material, its surface ionicity, or other physicochemical properties that should be studied in future studies.
  • Item
    Evaluation of tear meniscus by optical coherence tomography after different sodium hyaluronate eyedrops instillation
    (Acta Ophthalmologica, 2018) Carracedo Rodríguez, Juan Gonzalo; Pastrana Robles, Cristina; Serramito Blanco, María; Rodríguez-Pomar, Candela
    Purpose: To evaluate changes in tear meniscus dynamics using optical coherence tomography (OCT) after the instillation of different concentrations of sodium hyaluronate (SH) ophthalmic solutions. Methods: An experimental, double‐masked, randomized study was performed. Twenty‐three healthy subjects (16 women and seven men; mean age 23.57 ± 2.56 years) participated in this study. About 35 μl of 0.1%, 0.2%, 0.3% SH ophthalmic solutions and saline solution was instilled in a randomly assigned eye. Tear meniscus measurements (height, depth and turbidity) were taken with OCT at 30 seconds and 1, 3, 5, 10 and 20 min after instillation. Subsequently, the Schirmer test and tear break‐up time (TBUT) were evaluated. Results: Tear meniscus depth and tear meniscus height showed a significant increase with all solutions compared to basal values: up to 3 min for 0.1% SH, up to 5 min for 0.2% and up to 10 min for 0.3% SH ophthalmic solution. Tear meniscus turbidity was also increased at 30 seconds for 0.1%, 0.2% and 0.3% SH artificial tears (p < 0.05). This increase remained significant for up to 1 min for 0.2% and 0.3% SH solutions (p < 0.05). After 5 min of saline and 0.1% SH instillation, the turbidity was lower than basal values (p < 0.05). There was a significant increase in the TBUT for all solutions after instillation (p < 0.05). No differences between the Schirmer pre‐ and postinstillation were found (p > 0.05). Finally, the comfort was significantly improved for all ophthalmic solutions (p < 0.05). Conclusion: Sodium hyaluronate (SH) ophthalmic solutions increase residence time in healthy subjects and are positively correlated with its concentration and therefore the viscosity.
  • Item
    Stabilization of comfort and visual quality after the insertion of soft contact lenses
    (Contact Lens and Anterior Eye, 2021) Carpena Torres, Carlos; Pastrana Robles, Cristina; Rodríguez Pomar, Candela; Serramito Blanco, María; Carracedo Rodríguez, Juan Gonzalo
    Purpose: To evaluate comfort, visual function, and in vivo wettability after the insertion of hydrogel and silicone hydrogel contact lenses for a better understanding of how long practitioners should wait for the initial evaluation of soft contact lenses. Methods: A short-term prospective, contralateral, randomized, and participant-masked study was carried out. Twenty healthy participants (25.4 ± 2.6 years) were evaluated after the insertion of two different soft contact lenses at different times (1, 5, 10, 20, 30 min). Ocufilcon D (hydrogel) and Somofilcon A (silicone hydrogel) contact lenses were randomly assigned to both eyes of the same participant. Comfort, visual function under photopic conditions in terms of high-contrast visual acuity, low-contrast visual acuity, contrast sensitivity, and in vivo wettability were measured. Results: There was an increase in comfort (p < 0.001), high-contrast visual acuity (p < 0.05), and contrast sensitivity (p < 0.001, only with silicone hydrogel) directly related to time after contact lens insertion. Besides, in vivo wettability suffered a statistically significant deterioration directly related to time with both contact lenses (p < 0.05). Except for comfort and contrast sensitivity, all the parameters stabilized their values 10 min after the insertion of both soft contact lenses. Additionally, in vivo wettability and visual acuity differences were found between hydrogel and silicone hydrogel contact lenses (p < 0.05). Conclusions: It would be possible to properly evaluate high-contrast visual acuity, low-contrast visual acuity, and in vivo wettability 10 min after the insertion of both soft contact lenses.
  • Item
    Repeatability of Aberrometry-Based Automated Subjective Refraction in Healthy and Keratoconus Subjects
    (Journal of Ophthalmology, 2020) Carracedo Rodríguez, Juan Gonzalo; Carpena Torres, Carlos; Pastrana Robles, Cristina; Privado Aroco, Ana; Serramito Blanco, María; Batres Valderas, Laura
    Purpose. To compare the intersession repeatability of the Eye Refract, a new instrument to perform aberrometry-based automated subjective refraction, on healthy and keratoconus subjects. Materials and Methods. A cross-sectional and randomized study was performed. A total of 64 participants were evaluated in the study, selecting one eye per participant randomly. The sample was divided into two different groups: 33 healthy subjects (38.85 ± 13.21 years) and 31 with keratoconus (37.29 ± 11.37 years). Three refractions per participant with the Eye Refract were performed on three different days, without cycloplegia. The repeatability analysis of refractive variables (M, J0, and J45), binocular corrected distance visual acuity (BCDVA), and spent time in refraction was performed in terms of repeatability (Sr), its 95% confidence interval (r), and intraclass correlation coefficient (ICC). Results. There were no statistically significant differences (P ≥ 0.05) between sessions in both groups for all refractive variables (M, J0, and J45) and BCDVA. Spent time in refraction was reduced as the sessions went by (P < 0.05). The Eye Refract was more repeatable for refractive errors assessment in healthy subjects (M: Sr = 0.27 D; J0: Sr = 0.09 D; J45: Sr = 0.06 D) compared to those with keratoconus (M: Sr = 0.65 D; J0: Sr = 0.29 D; J45: Sr = 0.24 D), while it was similar for BCDVA. Conclusions. The Eye Refract offered better repeatability to assess refractive errors in healthy subjects compared to those with keratoconus. Despite measurements being also consistent in keratoconus subjects, they should be treated with caution in clinical practice.