Person:
Sánchez Ramos, Celia

Loading...
Profile Picture
First Name
Celia
Last Name
Sánchez Ramos
Affiliation
Universidad Complutense de Madrid
Faculty / Institute
Óptica y Optometría
Department
Optometría y Visión
Area
Optica
Identifiers
UCM identifierScopus Author IDDialnet IDGoogle Scholar ID

Search Results

Now showing 1 - 10 of 32
  • Item
    Lente de contacto terapeútica para ojos pseudo-afáquicos y/o en proceso de neurodegeneración
    (2006) Sánchez Ramos, Celia; Universidad Complutense de Madrid
    Lente de contacto terapéutica para ojos pseudo-afáquicos y/o en proceso de neurodegeneración. El objeto de la invención es una lente de contacto para ojos pseudo-afáquicos y/o con degeneración macular y retiniana caracterizada por ser resultante de la aplicación de un filtro con pigmentación amarilla sobre una lente de contacto común, con el fin de protegerlos de las longitudes de onda corta del espectro visible (inferiores a 500 nm) Esta invención elude las dificultades y riesgos de las técnicas existentes para dotar de esta protección a los ojos operados de cataratas y mejorar la de aquellos en procesos neurodegenerativos, lográndolo con la simple aplicación de una lente de contacto. La invención consta de la combinación de una lente de contacto común y un filtro de pigmentación amarilla que absorba las longitudes de onda corta de 350/500 nm, ambos adecuados para su uso en el ojo humano.
  • Item
    Estudio de los estados de refracción visual en jóvenes universitarios y su relación con el uso de ordenador
    (2002) Sánchez Ramos, Celia; Domínguez Carmona, Manuel; Romero Martín, Margarita
    Se analiza el estado de refracción en un colectivo de estudiantes universitarios en cuanto a frecuencia de las diferentes ametropías. Además se estudia la compensación óptica habitual de los estudiantes y se determina la presencia o ausencia de error en la compensación óptica habitual. Posteriormente y conociendo el estado de retracción se explora el estado de la función visual atendiendo a diversos aspectos: agudeza visual, vision binocular. En la población se presentan dos grupos de universitarios con una característica diferencial que corresponde a la utilización de ordenador. Finalmente se comparan los estados de refracción y de la funcion visual de ambos grupos para conocer las diferencias y la posible implicación que tiene en los aspectos anteriores, estado de refracción, funcion visual y sintomatología
  • Item
    Effect of a yellow filter on mesopic contrast perception and differential light sensitivity in the visual field.
    (Ophthalmic Research, 2003) Pérez Carrasco, María Jesús; Puell Marín, María Cinta; Sánchez Ramos, Celia; Langa Moraga, Antonio
    Purpose: Previous studies on the effects of yellow filters in the visual performance have been carried out, presenting discrepancies among the different investigations. Our study reports the influence of the yellow filter without residual reflections on contrast perception and differential light sensitivity (DLS) under mesopic conditions. Methods: Contrast sensitivity, low contrast visual acuity and luminance thresholds in the central visual field (30 degrees ) were measured in a group of 38 adult subjects with and without a coated yellow lens (482-nm cut-off) under mesopic conditions. Results: The contrast sensitivity mean was significantly better with the filter at low- and middle-range spatial frequencies (1.5 cycles/degree p = 0.002 and 6 cycles/degree p = 0.02). At 5% contrast, the mesopic low contrast visual acuity improved significantly (p = 0.004) when interposing the yellow filter. The increase in DLS was statistically significant [e.g. all visual fields p = 0.0003 and macular visual field (9.5 degrees ) p = 0.00001] through the yellow filter on the different established areas of the visual field (30 degrees ). Conclusions: The yellow filter without residual reflections had a positive influence on the brightness and contrast perception of healthy subjects, for which its use would be beneficial under mesopic conditions.
  • Item
    Normal values of distance heterophoria and fusional vergence ranges and effects of age.
    (Graefe´s Archive for Clinical and Experimental Ophthalmology, 2005) Palomo Álvarez, Catalina; Puell Marín, María Cinta; Sánchez Ramos, Celia; Villena Cepeda, Consuelo
    Background: Although it is well known that age affects visual function, we still have much to learn about the impact of aging on binocular vision. Our aim was to establish distance heterophoria and distance fusional vergence ranges in a large non-clinical population of wide age range, to provide normal values for comparisons. Methods: A cross-sectional study was performed on 271 non-clinical subjects stratified into six age groups. Distance heterophoria measurements were obtained using the von Graefe technique and distance horizontal fusional vergence ranges using Risley rotary prisms in each subject, with best spectacle correction. Results: The mean heterophoria value for distance fixation was exophoric except for the 71-80 year age group, which was esophoric. No effects of age were observed on distance heterophoria and distance base-in and base-out break means. However, a significant effect of age was noted on base-in recovery and base-out recovery. Between the youngest and oldest age groups, mean base-in recovery decreased by 2.5 Delta and mean base-out recovery by 3.3 Delta. Conclusions: Distance base-in and base-out recovery means diminished significantly with age such that recovery values fell outside the norm in subjects in the 61-70 year age group and older. This study establishes statistical normal values for distance heterophoria and fusional vergence in a non-clinical population. Mean values such as these are valuable tools for identifying subjects with far binocular anomalies.
  • Item
    Nuevo instrumento para medir la sensibilidad al contraste sin y con deslumbramiento
    (Archivos de la Sociedad Española de Oftalmología, 2003) Sánchez Ramos, Celia; Puell Marín, María Cinta; Pérez Carrasco, María Jesús; Langa Moraga, Antonio; Benítez Del Castillo Sánchez, José Manuel
    OBJETIVO/MÉTODO: valorar la sensibilidad al contraste fotópica, sin y con deslumbramiento con un nuevo instrumento. Se estudiaron 78 ojos derechos de 49 adultos jóvenes y de 29 adultos entre 35 y 55 años. La sensibilidad al contraste se midió con el Contrast Glarester CGT-1000 mediante una estrategia automatizada de reconocimiento para seis frecuencias espaciales. RESULTADOS/CONCLUSIONES: Los valores de sensibilidad al contraste fueron semejantes a los obtenidos con otros test clínicos. El aumento de la edad disminuyó significativamente la sensibilidad al contraste sin y con deslumbramiento. Sin embargo, el deslumbramiento no modificó la sensibilidad al contraste fotópica.
  • Item
    Bovine Tuberculosis (Mycobacterium bovis) in Wildlife in Spain
    (Journal of Clinical Microbiology, 2004) Aranaz Martín, Alicia; Juan Ferré, Lucía De; Montero Serra, Natalia; Sánchez Ramos, Celia; Galka, Margarita; Delso, Consuelo; Álvarez Sánchez, Julio; Romero Martínez, Beatriz; Bezos Garrido, Javier; Vela Alonso, Ana Isabel; Briones Dieste, Víctor; Mateos García, Ana Isabel; Domínguez Rodríguez, Lucas José
    Mycobacterium bovis infection in wildlife and feral species is a potential source of infection for livestock and a threat to protected and endangered species. The aim of this study was to identify Spanish wild animal species infected with M. bovis through bacteriological culture and spacer oligonucleotide typing (spoligotyping) of isolates for epidemiological purposes. This study included samples from red deer (Cervus elaphus), fallow deer (Dama dama), wild boar (Sus scrofa), Iberian lynx (Lynx pardina), hare (Lepus europaeus), and cattle (Bos taurus). They were collected in several geographical areas that were selected for their unique ecological value and/or known relationships between wildlife and livestock. In the areas included in this survey, M. bovis strains with the same spoligotyping pattern were found infecting several wild species and livestock, which indicates an epidemiological link. A locally predominant spoligotype was found in these areas. Better understanding of the transmission and distribution of disease in these populations will permit more precise targeting of control measures.
  • Item
    Mesopic contrast sensitivity in the presence or absence of glare in a large driver population.
    (Graefe's Archive for Clinical and Experimental Ophthalmology, 2004) Puell Marín, María Cinta; Palomo Álvarez, Catalina; Sánchez Ramos, Celia; Villena Cepeda, Consuelo
    Background: To evaluate mesopic contrast sensitivity in conditions of glare and no glare in a vehicle driver population, and to explore the effects of age, habitual spectacle correction, photopic visual acuity and driving exposure. Methods: A cross-sectional study was performed on 297 drivers stratified by age into six groups. The mesopic contrast sensitivity was measured in the absence or presence of glare using the Mesotest II (Oculus, Germany) in each subject both with habitual and best spectacle correction. A questionnaire on the subject's driving habits was completed. Results: There were no significant differences between contrast sensitivity measured with habitual or best spectacle correction. In conditions of no glare, the mesopic contrast sensitivity gradually got worse from 51 to 60 years onwards, and from 41 to 50 years onwards in the presence of glare. In both conditions, the total decrease in contrast sensitivity was 0.3 log units. The with-glare and without-glare mesopic contrast sensitivity improved as photopic visual acuity increased. Forty-five per cent of drivers who reported difficulties in driving at night were unable to perform any of the tests with glare, compared to 20% without glare. However, the effect of driving habits on contrast sensitivity was only significant in the oldest age group. Conclusions: The mesopic contrast sensitivity and glare sensitivity seem to be stable until the age of 50 years, from which point they start to decline at a rate of 0.1 log contrast sensitivity loss per decade. Drivers with poor visual acuity and/or older drivers who avoided night driving presented worse mesopic contrast sensitivity and greater glare sensitivity.
  • Item
    Contrast sensitivity and disability glare in patients with dry eye
    (Acta Ophthalmologica Scandinavica, 2006) Puell Marín, María Cinta; Benítez Del Castillo Sánchez, José Manuel; Martínez De La Casa Fernández-Borrella, José María; Sánchez Ramos, Celia; Aladro Vico, Eva; Pérez Carrasco, María Jesús; Pedraza Aranda, Constanza; Hierro Zarzuelo, Almudena, del
    Purpose: To evaluate contrast sensitivity and disability glare in patients with dry eye using the Contrast Glaretester 1000. Methods: Contrast sensitivity and disability glare were determined in 33 eyes of 33 patients with dry eye and 30 eyes of 30 healthy control subjects for six target sizes with a visual angle of 6.3-0.7 degrees using the Contrast Glaretester 1000, whose working mechanism is similar to that of the conventional perimetry instrument. Results: Contrast sensitivity was significantly worse in dry eye group when viewing all target sizes (reduction of 0.10-0.25 log contrast units, p < 0.01) except at 6.3 degrees. In the presence of glare, differences in log contrast sensitivity between the groups (0.10-0.25 units) were significant (p < 0.01) for all target sizes, with the dry eye group showing worse results. The reduction in contrast sensitivity induced by glare (disability glare) was significantly worse in the dry eye group versus the control group but only for the 2.5-degree size target, where 0.14 log contrast units were lost. Conclusions: Contrast sensitivity with and without glare was significantly reduced in patients with dry eye compared with control subjects, but the number of log contrast units lost with glare (disability glare) was similar in the two groups, except for the 2.5-degree size target.
  • Item
    Determinación del patrón de conectividad cerebral a partir de EEG en presencia de artefactos
    (Mapfre Medicina, 2007) Castellanos, Nazareth P.; Makarov Slizneva, Valeriy; Sánchez Ramos, Celia; Panetsos Petrova, Fivos
    Los diferentes estados del cerebro provocan la formación temporal de circuitos corticales cuya discriminación experimental abre el camino al estudio y caracterización de respuestas de comportamiento. En este trabajo recogemos e ilustramos en ejemplos los pasos necesarios para la determinación de patrones de conectividad funcional entre zonas corticales a partir de los registros EEG. El primer paso, la supresión de artefactos de diferentes tipos, se realiza mediante el análisis de componentes independientes que permite reconstruir la actividad neuroal subyacente al artefacto e indica en qué grado está presente el artefacto sobre cada electrodo. En el segundo paso determinamos la conectividad funcional a partir de registros preprocesados. Empleamos métodos estadísticos: la Coherencia Espectral Parcial y dDTF (direct Directed Transfer Function) que proporcionan un patrón de conectividad teniendo en cuenta el nivel de sincronización entre seáles de los electrodos.
  • Item
    Visión de contraste mesópica con y sin deslumbramiento en pacientes operados de miopía con la técnica Lasik.
    (Archivos Optométricos, 2001) Puell Marín, María Cinta; Sánchez Ramos, Celia; Barra Lázaro, Francisco; Villena Cepeda, Consuelo
    OBJETIVO: Comparar el umbral de contraste y la sensibilidad al contraste Pelli-Robson, en visión mesópica, con y sin deslumbramiento, en sujetos operados de miopía mediante cirugía Lasik y sujetos miopes no operados. MATERIAL Y MÉTODO: se realizó un estudio transversal de 44 ojos miopes (miopía inferior a 6 dioptrías) después de 1 año de Lasik, siendo el grupo control 52 ojos miopes no operados. El umbral de contraste con y sin deslumbramiento se midió con un Nyktómetro y la sensibilidad al contraste con el test de Pelli-Robson, utilizando el BAT para las preubas con deslumbramiento. En ambos casos el nivel de luminancia fue mesópico bajo. RESULTADOS: En el grupo Lasik el umbral de contraste mesópico (Nyctómetro) fue significativamente ppeor que en el grupo Control. Sin deslumbramiento, el 50% de los ojos del grupo Lasik no alcanzó el contraste límite (1-2-7) establecido por la Comisión de Oftalmología Alemana (DOG) para la conducción nocturna de vehículos particulares, frente a sólo el 17.3% del grpo Control. Pero con deslumbramiento, el contraste límite (1:5) no fue alcanzado por el 61.4% de los ojos del grupo LASIK y solo por el 28.8% del grupo Control. La media de sensibilidad al contraste mesópica (Pelli-Robson) fue inferior en el grupo Lasik. Sin embargo, con deslumbrmaiento no hubo diferencias significativas entre los dos grupos. Y tampoco hubo diferencias en las pérdidas de sensibilidad al contraste debidas al deslumbramiento (deslumbramiento discapacitante) CONCLUSIÓN: los ojos miopes operados con Lasik manifestaban al cabo de un año, un umbral de contraste mesópico sin y con deslumbramiento (Nyctómetro) superior al grupo control, y una disminución significativa d ela sensibilidad al contraste mesópica Pelli-Robson.