Person:
Antona Peñalba, Beatriz

Loading...
Profile Picture
First Name
Beatriz
Last Name
Antona Peñalba
Affiliation
Universidad Complutense de Madrid
Faculty / Institute
Óptica y Optometría
Department
Optometría y Visión
Area
Optica
Identifiers
UCM identifierORCIDScopus Author IDDialnet IDGoogle Scholar ID

Search Results

Now showing 1 - 9 of 9
  • Item
    Symptoms associated with reading from a smartphone in conditions of light and dark
    (Applied Ergonomics, 2018) Antona Peñalba, Beatriz; Barrio de Santos, Ana Rosa; Gascó Sánchez, Adriana; Pinar Rincón, Ana; González Pérez, Mariano; Puell Marín, María Cinta
    Asthenopia symptoms were investigated in visually-normal subjects without computer-related vision symptoms after prolonged reading from: smartphone versus hardcopy under photopic conditions, and smartphone in conditions of ambient versus dark room illumination. After reading from the smartphone, total symptom scores and nine out of ten questionnaire symptoms were significantly worse than for the hardcopy (“blurred vision while viewing the text, “blurred distance vision after the task”, “difficulty in refocusing from one distance to another”, “irritated or burning eyes”, “dry eyes”, “eyestrain”, “tired eyes”, “sensitivity to bright lights” and “eye discomfort”). Mean total symptom scores and scores for “irritated or burning eyes” and “dry eyes” were significantly higher for the dark versus photopic conditions. In conclusion, prolonged smartphone reading could cause worse asthenopic symptoms than reading from a hardcopy under similar conditions. Symptoms could be even worse when reading from a smartphone in the dark.
  • Item
    The Computer-Vision Symptom Scale (CVSS17): Development and Initial Validation
    (IOVS (Investigative Ophthalmology & Vision Science, 2014) González Pérez, Mariano; Susi García, María Del Rosario; Antona Peñalba, Beatriz; Barrio de Santos, Ana Rosa; González Díaz-Obregón, Enrique
    Purpose.: To develop a questionnaire (in Spanish) to measure computer-related visual and ocular symptoms (CRVOS). Methods.: A pilot questionnaire was created by consulting the literature, clinicians, and video display terminal (VDT) workers. The replies of 636 subjects completing the questionnaire were assessed using the Rasch model and conventional statistics to generate a new scale, designated the Computer-Vision Symptom Scale (CVSS17). Validity and reliability were determined by Rasch fit statistics, principal components analysis (PCA), person separation, differential item functioning (DIF), and item–person targeting. To assess construct validity, the CVSS17 was correlated with a Rasch-based visual discomfort scale (VDS) in 163 VDT workers, this group completed the CVSS17 twice in order to assess test-retest reliability (two-way single-measure intraclass correlation coefficient [ICC] and their 95% confidence intervals, and the coefficient of repeatability [COR]). Results.: The CVSS17 contains 17 items exploring 15 different symptoms. These items showed good reliability and internal consistency (mean square infit and outfit 0.88–1.17, eigenvalue for the first residual PCA component 1.37, person separation 2.85, and no DIF). Pearson's correlation with VDS scores was 0.60 (P < 0.001). Intraclass correlation coefficient for test–retest reliability was 0.849 (95% confidence interval [CI], 0.800–0.887), and COR was 8.14. Conclusions.: The Rasch-based linear-scale CVSS17 emerged as a useful tool to quantify CRVOS in computer workers.
  • Item
    From linear questionnaires to computer-adaptive tests: Content development and calibration of the Digital Eye Strain Computer Adaptive Test (DESCAT)
    (2022) Susi García, María Del Rosario; González Pérez, Mariano; Barrio De Santos, Ana Rosa; Antona Peñalba, Beatriz
    We published in 2015 a linear Rasch-based scale (Computer Vision Symptom Scale, aka CVSS17) for measuring the computer-related visual and ocular symptoms in workers using video-display terminals. Because Computer adaptive testing (CAT) is currently considered a more efficient and less time-consuming (for test-takers) method than traditional linear questionnaires, we decided to create a new CAT for assessing these symptoms in general population. Therefore, the aim of our study is to identify content for this new CAT and to calibrate the items included in it.
  • Item
    Project number: 357
    Aprendizaje guiado para la aplicación de ejercicios de Terapia Visual con un kit básico de tratamiento
    (2020) Barrio De Santos, Ana Rosa; Antona Peñalba, Beatriz; Sánchez Pérez, María Isabel; Piedrahita Alonso, María Elena; González Pérez, Mariano
  • Item
    Five levels of performance and two subscales identified in the computer-vision symptom scale (CVSS17) by Rasch, factor, and discriminant analysis
    (PLoS ONE, 2018) González Pérez, Mariano; Susi García, María Del Rosario; Barrio De Santos, Ana Rosa; Antona Peñalba, Beatriz
    Purpose: To quantify the levels of performance (symptom severity) of the computer-vision symptom scale (CVSS17), confirm its bifactorial structure as detected in an exploratory factor analysis, and validate its factors as subscales. Methods: By partial credit model (PCM), we estimated CVSS17 measures and the standard error for every possible raw score, and used these data to determine the number of different performance levels in the CVSS17. In addition, through discriminant analysis, we checked that the scale's two main factors could classify subjects according to these determined levels of performance. Finally, a separate Rasch analysis was performed for each CVSS17 factor to assess their measurement properties when used as isolated scales. Results: We identified 5.8 different levels of performance. Discriminant functions obtained from sample data indicated that the scale's main factors correctly classified 98.4% of the cases. The main factors: Internal symptom factor (ISF) and external symptom factor (ESF) showed good measurement properties and can be considered as subscales. Conclusion: CVSS17 scores defined five different levels of performance. In addition, two main factors (ESF and ISF) were identified and these confirmed by discriminant analysis. These subscales served to assess either the visual or the ocular symptoms attributable to computer use.
  • Item
    Spanish Cross-Cultural Adaptation, Rasch Analysis and Validation of the Ocular Comfort Index (OCI) Questionnaire
    (International Journal of Environmental Research and Public Health, 2022) Barrio De Santos, Ana Rosa; González Pérez, Mariano; Heredia Pastor, Clara; Enríquez Fuentes, Jacobo; Antona Peñalba, Beatriz
    The Ocular Comfort Index (OCI) assesses ocular surface irritation and grades the severity of dry eye disease. This study sought to adapt the OCI questionnaire into Spanish, and then to assess the psychometric performance and validity of the new adapted version (OCI-versión española, OCIVE). The questionnaire was translated, back translated, and then cross-culturally adapted for use with Spanish-speaking individuals. The OCIVE was completed by 450 participants, including 53 subjects that were diagnosed with dry eye disease. Through a Rasch analysis, the psychometric properties of item fit, targeting, person separation, reliability, and differential item functioning (DIF) were assessed. To test the convergent validity, we examined the correlation between the OCIVE and the Computer Vision Symptom Scale (CVSS17). Validity was tested in a subgroup of participants with and without dry eye, and test-retest repeatability was determined in a subset of 151 individuals. We also compared, via DIF, the performance of the OCIVE with that of the original OCI. Our Rasch analysis revealed a good model fit, high accuracy, good targeting, unidimensionality, and no DIF according to gender. The validity and repeatability were good. The OCIVE shows comparable psychometric properties to the original English version, making it a valid tool for measuring dry eye symptoms in Spanish adults.
  • Item
    Spanish Cross-Cultural Adaptation and Rasch Analysis of the Convergence Insufficiency Symptom Survey (CISS)
    (Translational Vision Science & Technology, 2020) González Pérez, Mariano; Pérez Garmendia, Carlos; Barrio De Santos, Ana Rosa; García Montero, María; Antona Peñalba, Beatriz
    Purpose: To culturally and linguistically adapt the Convergence Insufficiency Symptom Survey (CISS) to Spanish and assess the psychometric performance of the new version through Rasch analysis and classical test theory methods. Methods: The Spanish version of the CISS (CISSVE ) was completed by 449 subjects (9– 30 years old) from the general population. The validity and reliability of CISSVE were assessed through Rasch statistics (precision, targeting, item fit, unidimensionality, and differential item functioning). To test construct validity, we calculated the coefficients of correlation between the CISSVE and the Computer-Vision Symptom Scale (CVSS17) or Warwick–Edinburgh Mental Well-Being Scale (WEMWBS). We determined test–retest reliability in a subset of 229 subjects. We used differential item functioning (DIF) to compare the CISSSVE and the CISS after administering the CISS to 216 English children. Results: After applying exclusion criteria, the responses of 420 participants (mean age, 18.62 years; female, 54.95%) revealed good Rasch model fit, good precision (person separation = 2.33), and suboptimal targeting (–1.37). There was some evidence of multidimensionality, but disattenuated correlations between the Rasch dimension and a possible secondary dimension were high, suggesting they were measuring similar constructs. No item bias according to gender or age was detected. Spearman’s correlation was 0.34 (P < 0.001) for CISSVE –CVSS17 and non-significant for CISSVE –WEMWBS. The limits of agreement for test–retest reliability were 9.67 and –8.71. Rasch analysis results indicated no difference between CISS and CISSVE. Conclusions: According to our results, CISSVE is a valid and reliable tool for measuring the symptoms assessed by CISS in Spanish people 9 to 30 years of age. Translational Relevance: CISSVE can measure convergence insufficiency symptoms in Spanish-speaking subjects.
  • Item
    PhDAY 2020 -FOO (Facultad de Óptica y Optometría)
    (2020) Pintor Just, Jesús Jerónimo; Carpena Torres, Carlos; Peral Cerda, María Asunción; Pérez de Lara, María Jesús; Toral, Fernando; Crooke Álvarez, Almudena; Pastrana Robles, Cristina; Carracedo Rodríguez, Juan Gonzalo; Cayuela López, Ana; Sorzano Sánchez, Óscar; Charbel, Carla; Garzón Jiménez, Nuria; Carballo Álvarez, Jesús; Diz Arias, Elena; Fernández Jiménez, Elena; Lledó Mayans, Victoria Eugenia; Gómez Pedrero, José Antonio; Durán Prieto, Elena; López Alonso, José Manuel; Fernández Torres, Miguel Ángel; Guzmán Aránguez, Ana Isabel; Gómez Manzanares, Ángela; Vázquez Molini, Daniel; Martínez Antón, Juan Carlos; Bernárdez Vilaboa, Ricardo; Mayorga Pinilla, Santiago; Álvarez Fernández-Balbuena, Antonio; Benítez, AntoJ.; Igalla El-Youssfi, Asmae; León Álvarez, Alejandro; Palomo Álvarez, Catalina; Awad Alkozi, Hanan; Sánchez Naves, Juan; Martínez Alberquilla, Irene; García Montero, María; Ruiz Alcocer, Javier; Madrid Costa, David; Martínez Florentín, Gema; Papas, Eric B.; Medrano Muñoz, Sandra Milena; Molina, Nancy; Jurado, Sandra; Oliveiros López, Juan; Platero Alvarado, Nadiuska Cristine; Garrido Mercado, Rafaela; Pérez Garmendia, Carlos; Antona Peñalba, Beatriz; Barrio De Santos, Ana Rosa; González Pérez, Mariano; Pérez Garmendia, Carlos; Serramito Blanco, María; Privado Aroco, Ana; Almalki, Wael; Bodas Romero, Julia; Ouzzani, Mohamed; Paune, Jaume; Calderón García, Raquel; Pitarch Velasco, Aída; Cebrián, José Luis; Sánchez Pérez, María Isabel; García Rojo, Marta María; Bonnin Arias, Cristina Natalia; Sánchez Ramos, Celia; Gutiérrez Jorrín, Sara Carmen; Rodríguez Alonso, Xabier; Laucirica Sáenz, Gorka; Arranz Márquez, Esther; Alonso Castellanos, Miriam; Teus Guezala, Miguel Ángel; Hernández Verdejo, José Luis; Mármol Errasti, Esther; Martín García, Beatriz; Arriola Villalobos, Pedro; Gómez De Liaño Sánchez, María Rosario; Mínguez Caro, N; Orduña Azcona, Javier; Navarro Gil, Francisco Javier; Huete Toral, Fernando; Rodríguez Pomar, Candela; Martínez Águila, Alejandro; Martín Gil, Alba; Tomé de la Torre, Miguel Ángel
    Por cuarto año consecutivo los doctorandos de la Facultad de Óptica y Optometría de la Universidad Complutense de Madrid cuentan con un congreso propio organizado por y para ellos, el 4º PhDAY- FOO. Se trata de un congreso gratuito abierto en la que estos jóvenes científicos podrán presentar sus investigaciones al resto de sus compañeros predoctorales y a toda la comunidad universitaria que quiera disfrutar de este evento. Apunta en tu agenda: el 15 de octubre de 2020. En esta ocasión será un Congreso On-line para evitar que la incertidumbre asociada a la pandemia Covid-19 pudiera condicionar su celebración.
  • Item
    Intrasession repeatability and agreement of the anterior corneal assessment provided by a multidiagnostic device
    (Clinical and Experimental Optometry, 2024) Barrio De Santos, Ana Rosa; Antona Peñalba, Beatriz; Morago Villanueva, Sofía; Martínez Arribas, Víctor; González Pérez, Mariano
    Clinical relevance: Multidiagnostic systems have recently appeared on the market. Knowledge of the repeatability and validity of any instrument is mandatory before its introduction in clinical practice. Background: The aim of this work is to examine the intrasession repeatability of anterior pole measurements provided by the multidiagnostic device Wave Analyzer Medica 700 (WAM700) and agreement with Pentacam measurements in normal eyes. Methods: In the right eyes of 113 participants, three repeat measurements of central keratometry, central corneal thickness, anterior chamber depth and corneal eccentricity were made with the WAM700 and Pentacam in random order. Intrasession repeatability and agreement were determined. Results: Employing WAM700, intrasession repeatability for keratometry, central corneal thickness and anterior chamber depth was good (ICCs ≥ 0.992; CV 0.48-0.98%), yet worse than the values obtained for the Pentacam (ICCs ≥ 0.998; CV 0-0.33%). WAM700 showed excellent intrasession repeatability when used to measure the anterior chamber depth (Sw 0.03 mm). However, the repeatability of this device was inferior for central corneal thickness (Sw 4.24 μm) and keratometry measurements (Sw < 0.21 D) and was poor for corneal eccentricity (Sw 0.07; ICC 0.908; CV 14.58%). Agreement between WAM700 and Pentacam showed a high ICC for the keratometry measurements, central corneal thickness and anterior chamber depth (>0.972) but lower for corneal eccentricity (ICC 0.762). Conclusions: In healthy eyes, the WAM700 multidiagnostic device showed good intrasession repeatability for keratometry, central corneal thickness and anterior chamber depth measurements. Agreement between WAM700 and Pentacam was good for the anterior chamber depth measurement. However, these instruments cannot be considered interchangeable for keratometry, central corneal thickness and eccentricity readings.