Person:
Méndez Hernández, Carmen Dora

Loading...
Profile Picture
First Name
Carmen Dora
Last Name
Méndez Hernández
Affiliation
Universidad Complutense de Madrid
Faculty / Institute
Medicina
Department
Inmunología, Oftalmología y ORL
Area
Oftalmología
Identifiers
UCM identifierScopus Author IDDialnet ID

Search Results

Now showing 1 - 10 of 13
  • Publication
    Comparision of intraocular pressure measured using the new icare 200™ rebound tonometer and the Perkins™ applanation tonometer in healthy subjects and in patients with primary congenital glaucoma
    (Elsevier, 2021-04) Pérez García, Pilar; Morales Fernández, Laura; Sáenz Francés, Federico; Méndez Hernández, Carmen Dora; García Feijoo, Julián; Santos Bueso, Enrique; Martínez de la Casa, José María
    Objective: To compare intraocular pressure (IOP) measurements obtained using the Icare 200™ (IC200) rebound tonometer and the hand-held version of the Goldmann Applanation Tonometer (Perkins™ tonometer, GAT) in patients with primary congenital glaucoma (PCG) and in healthy subjects. Material and methods: A total of 42 eyes of healthy subjects (G1) and 40 patients with PCG (G2) were analysed. The following clinical data were collected: gender, age, Cup/Disc ratio, central corneal thickness (CCT). IOP was determined in the examination room using the IC200 and GAT tonometers, in the same order. Agreement between both tonometers was determined using the intraclass correlation coefficient (ICC) and Bland-Altman plot. A linear regression analysis was used to establish the IOP was affected by the studied variables. Results: Mean IOP between both tonometers (IC200 minus GAT) was: G1 = 15.91 (2.57) mmHg vs. 15.06 (2.12) mmHg (mean difference, MD = 0.84 (0.50) mmHg; P < .101) and G2=20.10 (6.37) vs.19.12 (5.62) (MD = 0.98 (1.36); P = 0.474). Excellent agreement was found between IC200 and GAT in both groups (ICC = G1: 0.875 (95% CI; 0.768−0.933; P < .001); G2: 0.924 (95% CI; 0.852−0.961; P < .001), and there was a statistically significant correlation between the IOP difference measured with IC200 and GAT and CCT in G1 (B=0.021; 95% CI; 0.005–0.037; P = .008), but was not statistically significant in G2. Conclusions: There was excellent agreement between the IC200 and GAT tonometers, both in healthy subjects and PCG, with a trend to overestimate IOP when measured with IC200. There was no influence by CCT on IOP measurements in patients with PGC.
  • Publication
    CPAMD8 loss-of-function underlies non-dominant congenital glaucoma with variable anterior segment dysgenesis and abnormal extracellular matrix
    (Springer-Verlag, 2020-04-09) Bonet Fernández, Juan Manuel; Aroca Aguilar, José Daniel; Corton Pérez, Marta; Ramírez Sebastián, Ana Isabel; Alexandre Moreno, Susana; García Antón, María Teresa; Salazar Corral, Juan José; Ferre Fernández, Jesús José; Atienzar Aroca, Raquel; Villaverde Montero, Cristina; Iancu, Ionut; Tamayo Durán, Alejandra; Méndez Hernández, Carmen Dora; Morales Fernández, Laura; Rojas López, Blanca; Ayuso García, Carmen; Coca Prados, Miguel; Martínez de la Casa, José María; García Feijoo, Julián; Escribano, Julio
    Abnormal development of the ocular anterior segment may lead to a spectrum of clinical phenotypes ranging from primary congenital glaucoma (PCG) to variable anterior segment dysgenesis (ASD). The main objective of this study was to identify the genetic alterations underlying recessive congenital glaucoma with ASD (CG-ASD). Next-generation DNA sequencing identified rare biallelic CPAMD8 variants in four patients with CG-ASD and in one case with PCG. CPAMD8 is a gene of unknown function and recently associated with ASD. Bioinformatic and in vitro functional evaluation of the variants using quantitative reverse transcription PCR and minigene analysis supported a loss-of-function pathogenic mechanism. Optical and electron microscopy of the trabeculectomy specimen from one of the CG-ASD cases revealed an abnormal anterior chamber angle, with altered extracellular matrix, and apoptotic trabecular meshwork cells. The CPAMD8 protein was immunodetected in adult human ocular fluids and anterior segment tissues involved in glaucoma and ASD (i.e., aqueous humor, non-pigmented ciliary epithelium, and iris muscles), as well as in periocular mesenchyme-like cells of zebrafish embryos. CRISPR/Cas9 disruption of this gene in F0 zebrafish embryos (96 hpf) resulted in varying degrees of gross developmental abnormalities, including microphthalmia, pharyngeal maldevelopment, and pericardial and periocular edemas. Optical and electron microscopy examination of these embryos showed iridocorneal angle hypoplasia (characterized by altered iris stroma cells, reduced anterior chamber, and collagen disorganized corneal stroma extracellular matrix), recapitulating some patients’ features. Our data support the notion that CPAMD8 loss-of-function underlies a spectrum of recessive CG-ASD phenotypes associated with extracellular matrix disorganization and provide new insights into the normal and disease roles of this gene.
  • Publication
    Efficacy and safety of the PreserFlo implant with mitomycin C in childhood glaucoma after previous failed glaucoma surgeries
    (Springer, 2023-05) Burgos Blasco, Bárbara; García Feijoo, Julián; Ginés Gallego, Cristina; Perucho González, Lucía; Fernández Vigo, José Ignacio; Martínez de la Casa, Jose Maria; Sáenz Francés, Federico; Morales Fernández, Laura; Méndez Hernández, Carmen Dora
    Purpose: This study aims to evaluate the efficacy and safety of the PreserFlo MicroShunt (Santen, Osaka, Japan) in lowering intraocular pressure (IOP) in childhood glaucoma patients with previous failed glaucoma surgeries. Methods: This is a prospective case review of consecutive PreserFlo procedures performed in childhood glaucoma patients after failed surgeries. Age, sex, diagnosis, and previous glaucoma surgeries, as well as visual acuity, IOP, and treatment in the preoperative visit and all follow-up visits were collected. Outcome measures included IOP reduction from baseline, mean IOP change from baseline at month 6, medication use at 6 months, complications, adverse events, and need for further procedures. Results: Fourteen patients were included, 8 (57%) males and 6 (43%) females; the mean age was 27.5 ± 13.5 years. Nine patients (64%) had at least two trabeculectomies, and 6 patients (43%) had at least one trabeculectomy and a glaucoma drainage implant. The mean IOP change from baseline was 11.3 ± 4.9 mmHg at 12 months. At 12 months, 12 patients (86%) presented ≥ 20% IOP lowering from baseline, and 11 patients (79%) presented ≥ 30%. The mean medication count decreased from 3.9 ± 0.7 (baseline) to 0.7 ± 1.3 (12 months). No intraoperative complications were reported. No adverse events were noted. No secondary filtration surgery was required, although bleb needling was required in one case, 1 month after the surgery. Conclusions: PreserFlo with MMC can be used successfully to treat uncontrolled IOP in childhood glaucoma cases with previous failed surgeries. Larger studies with longer follow-up are needed to further explore the role of the device in resistant childhood glaucoma cases.
  • Publication
    Agreement between rebound (Icare ic200) and applanation tonometry (Perkins) in patients with primary congenital glaucoma
    (John Wiley & Sons Ltd., 2020-12-23) Morales Fernández, Laura; Pérez García, Pilar; Sáenz Francés, Federico; Molero Senosiain, Mercedes; García Sáenz, Sofía; Méndez Hernández, Carmen Dora; Santos Bueso, Enrique; García Feijoo, Julián; Martínez de la Casa, Jose Maria
    Purpose: To examine agreement between intraocular pressure (IOP) measurements made using the rebound tonometer Icare ic200 (RT200) and the Perkins handheld applanation tonometer (PAT) in patients with primary congenital glaucoma (PCG). The impacts of several covariables on measurements using the two devices were also assessed. Materials and Methods: Intraocular pressure measurements were made in a single session in 86 eyes of 86 patients with PCG (46 under anaesthesia, 40 in the office). The order was RT200 then PAT. The variables age, central corneal thickness (CCT), corneal state and anaesthesia were recorded in each patient. Data were compared by determining interclass correlation coefficients (ICC) for each tonometer and representing the differences detected as Bland–Altman plots. Effects of covariables were assessed through univariate and multivariate regression. Results: Mean IOP difference between tonometers (RT200 minus PAT) was 1.26 mmHg (95%: 0.22–2.31). Absolute agreement (ICC) was 0.73 (95% CI: 0.62–0.82). Lower and upper limits of agreement (95%) were −8.06 mmHg (95% CI: −9.87 to −6.25) and 10.59 mmHg (95% CI: 8.77–12.40), respectively. The tonometers showed systematic differences (a = −4.63 mmHg; 95% CI: −9.11 to −1.44) and proportional differences; for each mmHg increase in PAT‐IOP, the RT200 reading increased by 1.28 mmHg (b = 1.28; 95% CI: 1.12–1.53). None of the variables tested as predictors were able to explain differences between the tonometers. Conclusions: Despite the good overall agreement between both tonometers, caution should be taken in high values of IOP, considering the interchangeability of its readings as systematic and proportional differences appear to exist between both methods.
  • Publication
    Charles Bonnet syndrome in a child with congenital glaucoma
    (Elsevier España, 2017-05-31) Santos Bueso, Enrique; Serrador García, Mercedes; Sáenz Francés, Federico; Méndez Hernández, Carmen Dora; Morales Fernández, Laura; Martínez de la Casa, Jose Maria; García Feijoo, Julián; Porta-Etessam, Jesús
    Case report: The case is presented of a 12 year-old boy with congenital glaucoma and low visual acuity diagnosed with Charles Bonnet syndrome. This consisted of the acute onset of complex, repetitive, persistent, and with visual hallucinations (people, brooms and coffeemakers) of self-limited evolution without treatment. The patient was diagnosed with congenital glaucoma at 3 years of age, and subjected to a trabeculectomy in right eye, and trabeculectomy and keratoplasty in his left eye. Discussion: Charles Bonnet syndrome symptoms have been described in adults, but their presence in children is poorly reflected in literature, with unknown characteristics and prevalence.
  • Publication
    Safety and Effectiveness of the PRESERFLO® MicroShunt in Primary Open-Angle Glaucoma: Results from a 2-Year Multicenter Study
    (Elsevier Inc., 2021-07-27) Beckers, Henny J.M.; Aptel, Florent; Webers, Carroll A.B.; Angeles, Raymund; Bluwol, Elisa; Martínez de la Casa, Jose Maria; García Feijoo, Julián; Lachkar, Yves; Méndez Hernández, Carmen Dora; Riss, Isabelle; Shao, Hui; Pinchuk, Leonard; Sadruddin, Omar; Shaarawy, Tarek M.
    To assess the safety and effectiveness of the PRESERFLO® MicroShunt (formerly InnFocus MicroShunt) in patients with primary open-angle glaucoma (POAG).The MicroShunt, a controlled ab externo glaucoma filtration surgery device, was investigated in a 2-year, multicenter, single-arm study.Eligible patients were aged 18-85 years with POAG inadequately controlled on maximal tolerated medical therapy with intraocular pressure (IOP) ≥18 and ≤35 mmHg or when glaucoma progression warranted surgery.The MicroShunt was implanted as a stand-alone procedure with adjunctive use of topical mitomycin C (MMC; 0.2-0.4 mg/ml) for 2-3 minutes.The primary effectiveness outcome was IOP reduction and success (not requiring reoperation or pressure failures [IOP > 21 mmHg and < 20% reduction in IOP]) at year 1. Additional end points at year 2 included IOP reduction, success, glaucoma medications, adverse events (AEs), and reoperations. Results are reported in the overall population and subgroups of patients receiving 0.2 or 0.4 mg/ml MMC.In 81 patients, mean (± standard deviation [SD]) IOP decreased from 21.7 ± 3.4 mmHg at baseline to 14.5 ± 4.6 mmHg at year 1 and 14.1 ± 3.2 mmHg at year 2 (P < 0.0001). Overall success (with and without supplemental glaucoma medication use) at year 1 was 74.1%. Mean (± SD) number of medications decreased from 2.1 ± 1.3 at baseline to 0.5 ± 0.9 at year 2 (P < 0.0001), and 73.8% of patients were medication free. Most common nonserious AEs were increased IOP requiring medication or selective laser trabeculoplasty (25.9%) and mild-to-moderate keratitis (11.1%). There were 6 (7.4%) reoperations and 5 (6.2%) needlings by year 2. In an analysis (post hoc) according to MMC concentration, overall success was 78.1% (0.2 mg/ml) and 74.4% (0.4 mg/ml; P = 0.710). In the 0.2 and 0.4 mg/ml MMC groups, 51.9% and 90.3% of patients were medication free, respectively (P = 0.001). There was a trend toward lower IOP and higher medication reduction in the 0.4 mg/ml MMC subgroup.In this study, mean IOP and glaucoma medication reductions were significant and sustained over 2 years postsurgery. No long-term, sight-threatening AEs were reported. Further studies may confirm potential risk/benefits of higher MMC concentration
  • Publication
    Reproducibility of peripapillary, optic nerve head and macular vessel density by OCT-A according to glaucoma severity staging
    (Elsevier, 2023-04-05) Salazar Quiñones, Liseth; Peña Urbina, Pilar; Fernández Vigo, José Ignacio; Pérez Quiñones, Y.; Molero Senosiain, Mercedes; Méndez Hernández, Carmen Dora; Martínez de la Casa, Jose Maria; García Feijoo, Julián
    Objective: To assess the reproducibility of peripapillary, optic nerve head (PP-ONH) and macular vessel density (VD) by Spectral Domain optical coherence tomography angiography (SD OCT-A) in glaucoma patients and healthy subjects. Methods: Cross-sectional study assessing 63 eyes of 63 subjects, including 33 glaucoma patients and 30 healthy subjects. Glaucoma was classified in mild, moderate, or advanced. Two consecutive scans were acquired by Spectralis Module OCT-A (Heidelberg, Germany), and provided images of the superficial vascular complex (SVC), nerve fiber layer vascular plexus (NFLVP), superficial vascular plexus (SVP); deep vascular complex (DVC), intermediate capillary plexus (ICP) and deep capillary plexus (DCP). VD (%) was calculated by AngioTool. Intraclass correlation coefficients (ICCs) and coefficients of variation (CV) were calculated. Results: Among PP-ONH VD, better ICC presented advanced (ICC 0.86–0.96) and moderate glaucoma (ICC 0.83–0.97) compared with mild glaucoma (0.64−0.86). For the macular VD reproducibility, ICC results for superficial retinal layers were better for mild glaucoma (0.94−0.96) followed by moderated (0.88−0.93) and advanced glaucoma (0.85−0.91), and for deeper retinal layers ICC was better for moderate glaucoma (0.95–0.96) followed by advanced (0.80−0.86) and mild glaucoma (0.74−0.91). CVs ranged from 2.2% to 10.94%. Among healthy subjects, ICCs for the PP-ONH VD measurements (0.91−0.99) and for the macular VD measurements (0.93−0.97) were excellent in all layers, with CVs from 1.65% to 10.33%. Conclusions: SD OCT-A used to quantify macular and PP-ONH VD showed excellent and good reproducibility in most layers of the retina, both in healthy subjects and in glaucoma patients regardless of the severity of the disease.
  • Publication
    Clinical outcomes of combined Preserflo Microshunt implantation and cataract surgery in open-angle glaucoma patients
    (Nature publishing group, 2021-08-02) Martínez de la Casa, Jose Maria; Sáenz Francés, Federico; Morales Fernández, Laura; Perucho González, Lucía; Méndez Hernández, Carmen Dora; Fernández Vidal, Ana M.; García Sáenz, Sofía; Sánchez Jean, Rubén; García Feijoo, Julián
    To assess the effectiveness and safety of the Preserflo Microshunt (PMS) implantation combined with cataract surgery in open-angle glaucoma (OAG) patients. Retrospective, open-label study conducted on insufficiently controlled OAG patients, who underwent a PMS implant procedure with mitomycin-C 0.2%, either alone or in combination with cataract surgery, and were followed for at least 12 months. Success was defined as an intraocular pressure (IOP) ≤ 18 mmHg and a reduction of at least 20% without (complete) or with (qualified) hypotensive medication. Fifty-eight eyes were included in the study, 35 eyes underwent PMS alone and 23 underwent PMS + Phaco. In the overall study sample, mean IOP was significantly lowered from 21.5 ± 3.3 mmHg at baseline to 14.6 ± 3.5 mmHg at month 12 (p < 0.0001). The IOP was significantly reduced in both groups; p < 0.0001 each, respectively. Ocular hypotensive medication was significantly reduced (p < 0.0001) in both groups. No significant differences were observed in IOP lowering or medication reduction between groups. At month 12, 62.1% eyes were considered as complete success and 82.8% eyes as qualified success. The most common adverse events were device close-to-endothelium, conjunctival fibrosis, and wound leakage. PMS, either alone or in combination with phacoemulsification, may be considered as a valuable option for treating OAG patients.
  • Publication
    Cese paradójico de un caso de síndrome de Charles Bonnet
    (Elsevier España, 2014-10) Santos Bueso, Enrique; Serrador García, Mercedes; Sáenz Francés, Federico; Méndez Hernández, Carmen Dora; Martínez de la Casa, Jose Maria; García Feijoo, Julián; García Sánchez, Julián
    Caso clínico: paciente varón de 78 años diagnosticado de síndrome de Charles Bonnet (SCB) por déficit visual secundario a glaucoma terminal. Evolucionó a amaurosis, presentando desaparición brusca de las alucinaciones de forma paralela a la pérdida del resto visual. Discusión: el cese paradójico del SCB se produce cuando el paciente pierde el resto visual, evolucionando a amaurosis. La falta de estimulación en la retina y el córtex correspondiente hacen desaparecer las alucinaciones debido a que las neuronas desaferentadas e hiperexcitadas pierden el estímulo que desencadena el SCB.
  • Publication
    Effect of Hypercholesterolemia, Systemic Arterial Hypertension and Diabetes Mellitus on Peripapillary and Macular Vessel Density on Superficial Vascular Plexus in Glaucoma
    (MDPI, 2023-02-06) Sanz Gomez, María; Zeng, Ni; Catagna Catagna, Gloria Estefania; Arribas Pardo, Paula; García Feijoo, Julián; Méndez Hernández, Carmen Dora
    Background/Aims: Vascular factors are involved in the development of glaucoma, including diseases such as hypercholesterolemia (HC), systemic arterial hypertension (SAH), and diabetes mellitus (DM). The aim of this study was to determine the effect of glaucoma disease on peripapillary vessel density (sPVD) and macular vessel density (sMVD) on the superficial vascular plexus, controlling differences on comorbidities such as SAH, DM and HC between glaucoma patients and normal subjects. Methods: In this prospective, unicenter, observational cross-sectional study, sPVD and sMVD were measured in 155 glaucoma patients and 162 normal subjects. Differences between normal subjects and glaucoma patients’ groups were analyzed. A linear regression model with 95% confidence and 80% statistical power was performed. Results: Parameters with greater effect on sPVD were glaucoma diagnosis, gender, pseudophakia and DM. Glaucoma patients had a sPVD 1.2% lower than healthy subjects (Beta slope 1.228; 95%CI 0.798–1.659, p < 0.0001). Women presented 1.19% more sPVD than men (Beta slope 1.190; 95%CI 0.750–1.631, p < 0.0001), and phakic patients presented 1.7% more sPVD than men (Beta slope 1.795; 95%CI 1.311–2.280, p < 0.0001). Furthermore, DM patients had 0.9% lower sPVD than non-diabetic patients (Beta slope 0.925; 95%CI 0.293–1.558, p = 0.004). SAH and HC did not affect most of the sPVD parameters. Patients with SAH and HC showed 1.5% lower sMVD in the outer circle than subjects without those comorbidities (Beta slope 1.513; 95%CI 0.216–2.858, p = 0.021 and 1.549; 95%CI 0.240–2.858, p = 0.022 respectively. Conclusions: Glaucoma diagnosis, previous cataract surgery, age and gender seem to have greater influence than the presence of SAH, DM and HC on sPVD and sMVD, particularly sPVD.