  • Item
    The role of clinical diagnosis criteria on the frequency of accommodative insufficiency
    (International journal of ophthalmology, 2019) García Montero, María; Antona Peñalba, Beatriz; Barrio de Santos, Ana Rosa; Nieto Zayas, Carmen; Martínez Alberquilla, Irene; Hernández Verdejo, José Luis
    AIM: To estimate and compare the frequency of accommodative insufficiency (AI) within the same clinical population sample depending on the type of clinical criteria used for diagnosis. Comparing the frequency within the same population would help to minimize bias due to sampling or methodological variability. METHODS: Retrospective study of 205 medical records of symptomatic subjects free of any organic cause and symptoms persisting despite optical compensation evaluated. Based on the most commonly clinical diagnostics criteria found in the literature, four diagnostics criteria were established for AI (I, II, III and IV) based on subjective accommodative tests: monocular accommodative amplitude two or more diopters below Hofstetter’s minimum value [15-(0.25×age)] (I, II, III, IV); failing monocular accommodative facility with minus lens, establishing the cut-off in 0 cycles per minute (cpm) (I) and in 6 cpm (II, III); failing binocular accommodative facility with minus lens, establishing the cut-off in 0 cpm (I) and in 3 cpm (II). RESULTS: The proportion of AI (95%CI) for criteria I, II, III and IV were 1.95% (0.04%-3.86%), 2.93% (0.31%-4.57%), 6.34% (1.90%-7.85%) and 41.95% (35.14%-48.76%) respectively, with a statistically significant difference shown between these values (χ2=226.7, P<0.001). A pairwise multiple comparison revealed that the proportion of AI detected for criterion IV was significantly greater than the proportion for the rest of the criteria (P-adjusted<0.05 in all cases). CONCLUSION: The prevalence of cases of AI within the same clinical population varies with the clinical diagnostic criteria selected. The variation is statistically significant when considering the monocular accommodative amplitude as the only clinical diagnostic sign.
  • Item
    Effects of Blink Rate on Tear Film Optical Quality Dynamics with Different Soft Contact Lenses
    (Journal of Ophthalmology, 2019) García Montero, María; Rico del Viejo, Laura; Martínez Alberquilla, Irene; Hernández Verdejo, José Luis; Lorente Velázquez, Amalia; Madrid Costa, David
    Objective. The aim of this study was to investigate tear film optical quality dynamics for four types of silicone hydrogel contact lenses (SHCLs) for daily wear over a 15-day period and for different blink rate (BR) patterns. Methods. A prospective randomized, double-blind, cross-over pilot study including four SHCLs (A: lotrafilcon B (Air Optix plus HydraGlyde, Alcon Laboratories); B: samfilcon A (Ultra, Bausch & Lomb); C: comfilcon A (Biofinity, CooperVision); and D: filcom V3 (Blu:gen, Mark’Ennovy)). Serial measurements of Objective Scatter Index (OSI) using the HD Analyzer (Visiometrics S.L., Terrassa, Spain) were taken at different blinking patterns: blinking every 2.5 seconds (high BRs) and every 9 seconds (low BRs). They were performed during the first visit before CL insertion (baseline), after 20 minutes of CL wear (Day 1), and during the last visit after 8 hours of CL wear on day 15 of use (Day 15). Results. Normal young healthy subjects were recruited and fitted with the four lenses. For low BRs, the mean OSI value increased over time for all CLs and the slope of the curve also increased for all CLs, except for CL D. However, for high BRs, the mean OSI value increased only for CLs B and C and the slope of the curve did not change over time for any of them. Conclusions. These results suggest that the tear film optical quality dynamics after wearing SCHLs for 15 days seems to undergo a slight deterioration only for lowest BR.
  • Item
    Ocular Surface Temperature in DED under Natural Non-Controlled Blinking Conditions
    (Applied Sciences, 2022) Rico del Viejo, Laura; Llorens Quintana, Clara; Martínez Alberquilla, Irene; Madrid Costa, David; García Montero, María
    Infrared (IR) thermography is a tool to non-invasively assess the tear film temperature. The aim was to analyze ocular surface temperature (OST) variations in dry eye disease (DED) and control eyes under natural non-controlled blinking conditions. Imaging was performed with a thermal camera (FLIR Systems Inc.) at 30 Hz framerate in 79 participants (39 DED (62.5% women, average age 48 ± 20 years) and 40 control (46.2 % women, average age 38 ± 13 years)) using non-contact IR thermography camera. Data acquisitions were performed in natural blinking conditions for 40 s. IR images were analyzed using a custom algorithm that calculates the OST indexes: mean OST, OST at the start and at the end, minimum and maximum OST, and tear evaporation rate (TER). No significant differences were found between groups in any thermal parameter analyzed (paired comparisons t-test, p > 0.05). In conclusion, the findings of this study did not reveal significant differences between DED and control eyes under natural non-controlled blinking conditions. However, the presence of clinical signs in the control group may affect the results, highlighting the role of DED diagnosis criteria.
  • Item
    Changes in Optical Quality Induced by Tilt and Decentration of a Trifocal IOL and a Novel Extended Depth of Focus IOL in Eyes with Corneal Myopic Ablations
    (Journal of Refractive Surgery, 2021) Ruiz Alcocer, Javier; Martínez Alberquilla, Irene; Rementería Capelo, Laureano A; Gracia Pacheco, Pablo de; Lorente Velázquez, Amalia
    PURPOSE: To assess the effect of decentration and tilt combined with prior myopic ablations on the optical performance of a trifocal intraocular lens (IOL) and a novel IOL with an extended depth of focus (EDOF) design. METHODS: The XACT Mono-EDOF ME4 (Santen Pharmaceutical Co Ltd) and the trifocal FineVision (PhysIOL) IOLs were analyzed with and without simulated previous myopic ablations. The optical quality of the IOLs was evaluated with the PMTF optical bench (LAMBDA-X). The through-focus modulation transfer function (MTF) curves were recorded. Measurements were done for three situations: centered, 0.4 mm decentered, and 4 degrees tilted. RESULTS: The trifocal IOL showed three peaks of vision and the EDOF IOL showed a far distance peak with intermediate addition. When decentration or tilt were induced, the trifocal IOL showed negligible changes but the EDOF IOL showed a -0.50 diopters (D) shift of the overall curve. With simulated myopic ablation, the trifocal IOL showed a -0.50 D shift of the curve. When tilt or decentration were also induced, the better optical results were found at -1.00 D. With myopic ablations, the EDOF IOL showed a -0.50 D shift of the optical quality and when decentration or tilt were then induced, negative shifts over -1.00 D were found. CONCLUSIONS: The trifocal IOL was less affected by misalignments. When myopic ablations were induced, both lenses decreased their optical quality and the effects of misalignments were higher. In patients who have undergone corneal myopic ablation procedures, proper alignment of the implanted IOL and obtaining effective emmetropia becomes even more critical.
  • Item
    Repeatability of Noninvasive Keratograph 5M Measurements Associated With Contact Lens Wear
    (Eye & Contact lens, 2019) García Montero, María; Rico del Viejo, Laura; Lorente Velázquez, Amalia; Martínez Alberquilla, Irene; Hernández Verdejo, José Luis; Madrid Costa, David
    Objetive: To assess the intrarater repeatability of the measurements of tear meniscus height (TMH), noninvasive keratograph tear break-up time (NIKBUTs), and ocular redness measurements obtained with the Keratograph 5M (K5M) in a sample of soft silicone hydrogel contact lens (CL) wearers over 15 days. Methods: Prospective study over two consecutive weeks. Three measurements of TMH, NIKBUTs (NIKBUT first and NIKBUT average), and ocular redness were obtained in different sessions; the first day (baseline, at 8 hr of wear, and after lens removal) and the last day of wear-15th day (at 8 hr of wear and after lens removal). The repeatability of measurements were assessed by two intraclass correlation coefficient (ICC) forms; single measurement [ICC (2,1)] and multiple measurements (k=3) [ICC (2, k)]. Results: Sixty-four eyes were analyzed. The repeatability of baseline TMH [ICC (2,1) greater than 0.90; coefficient of repeatability (CR)=0.06 mm] and after and during CL wear [ICC (2,k) greater than 0.90; CR≤0.07 mm] were excellent. The repeatability of baseline NIKBUT average [ICC (2,k)=0.89 (0.82-0.93); CR=6.07 sec] was maintained after CL removal but was poorer during CL wear. The repeatability of baseline NIKBUT first [ICC (2,k) =0.80 (0.69-0.87); CR=8.74 sec] was maintained after CL removal and during CL wear at moderate-good level. Conclusions: Intrarater repeatability of TMH, NIKBUTs, and ocular redness performed by K5M after CL wear remains stable when three measurements are performed. However, intrarater repeatability during CL wear decreased only for NIKBUT average and was not affected by time of use (15 days).
  • Item
    The Topographical Effect of Optical Zone Diameter in Orthokeratology Contact Lenses in High Myopes
    (Journal of Ophthalmology, 2019) Carracedo Rodríguez, Juan Gonzalo; Espinosa Vidal, Teresa M.; Martínez Alberquilla, Irene; Batres Valderas, Laura
    Purpose. To evaluate the effect of the optical zone diameter (OZ) in orthokeratology contact lenses regarding the topographical profile in patients with high myopia (−4.00 D to −7.00 D) and to study its effect over the visual quality. Materials and Methods. Twelve patients (18 eyes) were fitted with overnight orthokeratology (OrthoK) with a randomized 6 mm or 5 mm OZ lens worn for 2 weeks, followed by a 2-week washout period, between both designs. Keratometry (K) readings, optical zone treatment diameter (OZT), peripheral ring width (PRW), higher-order aberrations (HOA), high (HC) and low contrast (LC) visual acuity, and subjective vision and comfort were measured at baseline and after 2 weeks of OrthoK lens wear of each contact lens. Results. No significant differences were found between any measurements for the same subject at both baselines ( value > 0.05). There was no difference between OZ lens designs found in refraction, subjective vision or comfort, and HC and LC visual acuity. Contrast sensitivity was decreased in the 5 mm OZ lens design compared with 6 mm OZ design (-value < 0.05). 5 mm OZ design provoked a greater flattening, more powerful midperipheral ring and 4th-order corneal and total spherical aberration than the 6 mm OZ design, being statistically significant after 7 days, for corneal aberration, and 15 days, for corneal and total, of wearing the lens (-value < 0.05). The OZT obtained were 2.8 ± 0.2 mm and 3.1 ± 0.1 mm for 5 mm and 6 mm OZ design, respectively (-value < 0.05). Regarding PRW, the 5 mm OZ design had a wider ring width in both the nasal and temporal zones (-value < 0.05). Conclusions. A smaller diameter optical zone (5 mm) in orthokeratology lenses produces a smaller treatment area and a larger and more powerful midperipheral ring, increasing the 4th-order spherical aberration that affects only the contrast sensitivity but without differences in visual acuity and subjective vision compared with a larger OZ diameter (6 mm).
  • Item
    Forward-scattered and backward-scattered light in moderate keratoconus
    (Ophthalmic and Physiological Optics, 2023) Villanueva Gómez-Chacón, Celia; Viviano, Francesco; García Montero, María; Lorente Velázquez, Amalia; Martínez Alberquilla, Irene; Garzón Jiménez, Nuria
    Introduction: To evaluate the backscattered light, objective scatter index (OSI) and retinal straylight in patients with moderate keratoconus and healthy control subjects. Methods: A prospective observational study was developed with 33 patients in the moderate-keratoconus group (KC) and 34 in the non-keratoconus group (NKC). Corneal densitometry was obtained using Scheimpflug corneal tomography and measurements were expressed in grayscale units (GSU) over four zones within a 12.00 mm diameter around the corneal apex. A straylight meter was used to determine the amount of intraocular straylight under scotopic conditions, and the straylight parameter (LOG(s)) and test duration were recorded. The Optical Quality Analysis System based on the double-pass technique determined the OSI value. Results: Significant differences were observed between the KC and NKC groups for corneal densitometry (except in the 6–10 mm zone), OSI and retinal straylight. A moderate and significant correlation was found between OSI and retinal straylight LOG(s) (r = 0.52, p = 0.002). Weaker and non-significant correlations were found between corneal densitometry and the other parameters analysed (i.e., OSI, retinal straylight LOG(s) and retinal straylight times). Conclusions: Backscattered light, retinal straylight and the OSI show clear differences between healthy eyes and those with moderate KC. The changes present in the stages of KC evaluated in the current study (stages II and III according to the Amsler–Krumeich classification) might alter the scattering of the light entering the eye.
  • Item
    Triple Procedure: A Stepwise Combination of Deep Anterior Lamellar Keratoplasty and Cataract Surgery
    (Córnea, 2023) Alfonso Bartolozzi, Belén; Fernández Vega Cueto, Luis; Fernández-Vega, Luis; Martínez Alberquilla, Irene; Madrid Costa, David; Alfonso, José F.
    Purpose: The aim of this study was to evaluate clinical outcomes of the combined surgery (triple procedure) of deep anterior lamellar keratoplasty (DALK), phacoemulsification, and intraocular lens (IOL) implantation using a new surgical strategy. Methods: The study included 43 eyes of 43 patients who underwent a triple procedure. Twenty-six eyes with good visibility through the cornea underwent phacoemulsification before the stromal dissection. Seventeen eyes with bad visibility underwent the DALK procedure first until achieving enough visibility to perform the lensectomy. IOL power calculation was performed for a postoperative estimated flat keratometry of 43.5 and aiming to avoid hyperopic postoperative refraction. The postoperative visual examination included uncorrected and corrected distance visual acuity (CDVA) measurements and manifest refraction. Results: The mean follow-up time after suture removal was 3.06 ± 2.14 years. Mean CDVA significantly changed from 0.86 ± 0.56 logMAR preoperatively to 0.37 ± 0.28 logMAR in the last visit (P < 0.0001). The percentage of eyes with CDVA ≤0.3 logMAR changed from 6.9% preoperatively to 62.8%. No eyes lost lines of vision after surgery, and 80% experienced an improvement of 2 or more lines. The safety index was 2.2. The mean postoperative refractive sphere was +0.13 ± 2.04 D, and the postoperative refractive cylinder was -4.02 ± 2.24 D. Only 2 cases (4.65%) obtained postoperative hyperopic astigmatism. No intraoperative complications were found. Conclusions: Combined surgery of DALK, phacoemulsification, and IOL implantation is an effective and safe procedure. Depending on the corneal transparency, different surgical strategies can be established to provide more efficacy and safety.
  • Item
    Impact of contact lens wear on NLRP3 gene expression: Implications for ocular frailty in middle-aged adults
    (Experimental Eye Research, 2020) Crooke Álvarez, Almudena; Martínez Alberquilla, Irene; García Montero, María; Rico Del Viejo, Laura; Ruiz Alcocer, Javier; Madrid Costa, David
    The inflammatory process plays a crucial role in frailty syndrome, which can appear in middle age and is associated with a poor health outcome. Consequently, gerontologists recommend screening inflammatory biomarkers in middle-aged adults to detect frailty and, therefore, prevent chronic diseases and mortality. External factors could be a risk factor for frailty because they can generate and extend the inflammatory process. For these reasons, we analysed the effect of long-term contact lens wear on mRNA level of genes linked to inflammation (IL-6, NLRP3, NK1R, CD73, MUC16 and TRPV1 genes) in conjunctival cells of middle-aged individuals, by quantitative PCR. Middle-aged contact lens wearers presented a significant increase of NLRP3 and MUC16 mRNA level as well as a decrease of CD73 mRNA level, in comparison with non-contact lens wearers. Additionally, we checked for a potential correlation between these transcript levels and clinical changes of the participants’ ocular surface. Unlike molecular analysis, clinical examination fails to detect inflammation in contact lens wearers. These data suggest that long-term contact lens wear could trigger an inflammatory response in middle age orchestrated by NLRP3 inflammasome and modulated by CD73 and MUC16 proteins. Further studies are needed to confirm our gene expression findings at the protein level as well as to investigate the potential role of long-term CL wear in the onset of ocular frailty.
  • Item
    Visual function, ocular surface integrity and symptomatology of a new extended depth-of-focus and a conventional multifocal contact lens
    (Contact Lens and Anterior Eye, 2020) Martínez Alberquilla, Irene; García Montero, María; Ruiz Alcocer, Javier; Crooke Álvarez, Almudena; Madrid Costa, David
    Purpose: To evaluate visual function, ocular surface integrity and dry eye symptoms with an extended depth-of-focus (EDOF) design and a conventional multifocal (MF) contact lens (CL) after 15 days of wear. Methods: A crossover single mask randomised clinical trial was conducted including 30 presbyopes who used an EDOF and a conventional MF CL (Biofinity MF) for 15 days each. Defocus curves, depth-of-focus range, contrast sensitivity (CS) under photopic and mesopic conditions (with and without glare) and subjective perception of halos and glare were evaluated. The ocular surface was evaluated through non-invasive Keratograph tear breakup time (NIKBUT), averaged tear breakup time (NIKBUT-avg), tear meniscus height (TMH), bulbar and limbal redness, and conjunctival and corneal staining. Dry eye symptoms were assessed with the OSDI questionnaire. Results: No statistically significant differences were found for defocus curves or depth-of-focus between the two CLs (both p > 0.05). Subjective perception of halos and glare was not significantly different between CLs. Statistically significant differences were observed for CS under mesopic conditions for low spatial frequencies (p = 0.008). None of the CL produced significant changes in NIKBUT, NIKBUT-avg, TMH or redness. No change in conjunctival staining was observed in 76.7 % and 73.3 % of participants for EDOF and Biofinity MF, respectively. No change in corneal staining was observed in 86.7 % and 83.3 % of participants for EDOF and Biofinity MF, respectively. No changes were observed in the symptomatology measured with OSDI questionnaire (p > 0.05). Conclusions: Both CL for presbyopia offer good visual quality, preserve the ocular surface integrity and provide the patient with similar symptomatology levels after 15 days of lens wear.