Person:
Calvo Lobo, César

Loading...
Profile Picture
First Name
César
Last Name
Calvo Lobo
Affiliation
Universidad Complutense de Madrid
Faculty / Institute
Enfermería, Fisioterapia y Podología
Department
Enfermería
Area
Fisioterapia
Identifiers
UCM identifierORCIDScopus Author IDWeb of Science ResearcherIDDialnet IDGoogle Scholar ID

Search Results

Now showing 1 - 10 of 12
  • Item
    Effectiveness of Eccentric Exercise and a Vibration or Cryotherapy Program in Enhancing Rectus Abdominis Muscle Thickness and Inter-Rectus Distance in Patients with Chronic Mid-Portion Achilles Tendinopathy: A Randomized Clinical Trial
    (International journal of medical sciences, 2018) Romero Morales, Carlos; Martín Llantino, Pedro Javier; Calvo Lobo, César; Beltran Alacreu, Hector; López-López, Daniel; Sánchez Gómez, Rubén; Rodríguez Sanz, David
    Purpose: Abdominal muscles are key in maintaining body stability and balance and an improvement in the functioning of these muscles could influence the rehabilitation process in lower limb pathologies such as Achilles Tendinopathy (AT). The aim was to explore whether calf eccentric exercise (EE) with vibration training was more effective at causing adaptation to the rectus anterior (RA) thickness and inter-rectus distance (IRD) than calf EE with cryotherapy. Methods: The investigation was a single-blinded, randomized, controlled clinical trial (NCT03515148). Sixty-one individuals diagnosed with mid-portion AT were recruited and divided in two groups: group A (n = 30) followed an EE with vibration program and group B (n = 31) an EE program with cryotherapy, for 12-weeks. RA muscle thickness and IRD were measured in maximal isometric contraction and at rest as an indication of superficial abdominal muscle activation. Results: IRD measures showed a significant (P < 0.05) decrease at baseline, 4 and at 12-weeks in both groups, but no significant differences were observed between the intervention groups. RA thickness was significantly increased (P < 0.05) in measures at baseline, 4 and 12-weeks showed a significant increase in maximal isometric contraction and at rest in favor of the EE vibration program group. Conclusions: The present study showed a RA thickness increase in both groups in favor of the EE vibration program with respect to cryotherapy added to EE in short and mid term in maximal isometric contraction and at rest in subjects with chronic mid-portion AT. IRD was decreased in both groups without between-groups differences.
  • Item
    Effect of the cushioning running shoes in ground contact time of phases of gait
    (Journal of the mechanical behavior of biomedical materials., 2018) Roca Dols, Andrea; Losa Iglesias, Marta Elena; Sánchez Gómez, Rubén; Becerro De Bengoa Vallejo, Ricardo; López López, Daniel; Rodríguez Sanz, David; Martínez Jiménez, Eva María; Calvo Lobo, César
    The main objective of this research was to know how five different cushioning shoes may interfere in ground contact times of each gait phase of walking and running in contrast with barefoot condition. Thirty healthy sport recreational male runners participated in this study. They played over a treadmill wearing minimalist, Boost®, Ethyl-vinyl-acetate (EVA), Air® chamber and pronation-control cushioning shoes technologies and under barefoot condition, recording the last 30 s of walking and running at 5.17 km/h and 9 km/h respectively, while ground contact time duration of each phase of gait was recorded with circular standard pressure sensors located on plantar feet. During walking, the heel contact phase was the station that increased significantly ground contact times wearing all sole cushioning shoes (p < 0.001), excepting no sole shoes (minimalist), versus barefoot condition, being Air® chamber the model that showed the highest times of contact floor versus barefoot (0.28 ± 0.08 ms and 0.23 ± 0.12 ms vs 0.12 ± 0.07 ms and 0.18 ± 0.07 ms in heel contact during midstance phases, respectively). During running, propulsion phase was the station that showed the highest spent times on ground contact with the floor under all shoe conditions, even with minimalist, being again Air® chamber the model with higher significant times in two of three phases versus barefoot (0.11 ± 0.04 ms and 0.16 ± 0.11 ms vs 0.09 ± 0.03 ms and 0.10 ± 0.02 ms in midstance and propulsion phases respectively). Air chamber® was the model too with the most switch ratio to forefoot strike pattern (0.07 ± 0.10 ms to 0.16 ± 0.11 from heel contact to propulsion phase, respectively). In conclusion, a ground contact times increase using all cushioning running shoes compared with barefoot condition was shown in both walking and running test.
  • Item
    Effects of Myofascial Induction Therapy on Ankle Range of motion and Pressure Pain Threshold in trigger points of the gastrocnemius. A clinical trial.
    (Biomedicines, 2023) Martínez Jiménez, Eva María; Jiménez Fernández, Raquel; Corral Liria, Inmaculada; Rodríguez Sanz, David; Calvo Lobo, César; López López, Daniel; Pérez Boal, Eduardo; Trevissón Redondo, Bibiana; Grande del Arco, Jessica
    Background: The myofascial induction technique (MIT) has been shown to increase shoulder range of motion (ROM) in breast cancer survivors and decrease pain pressure threshold over the radial nerve in patients with epicondylalgia. To the authors’ best knowledge, no study on trigger points and MIT has been published to date. The effect on ROM of latent trigger points is also unknown. Methods: A total of 20 twins with one latent trigger point of the gastrocnemius muscle were evaluated pre- and post-MIT in the calf. We measured static footprint variables in a pre–post study. Results: We found differences in PPT (p = 0.001) and no differences in ROM with knee flexed (p = 0.420) or stretched (p = 0.069). Conclusions: After Calf MIT, latent myofascial trigger points improve PPT but no change in ankle dorsiflexion with knee bent or knee flexed were found in non-restriction healthy subjects.
  • Item
    An Automated Blood Pressure Display for Self-Measurement in Patients with Chronic Kidney Disease (iHealth Track): Device Validation Study
    (JMIR mHealth and uHealth, 2020) Mazoteras Pardo, Victoria; Becerro De Bengoa Vallejo, Ricardo; Losa Iglesias, Marta Elena; López López, Daniel; Calvo Lobo, César; Rodríguez Sanz, David; Martínez Jiménez, Eva María; Palomo López Patricia
    Background: Hypertension is a global public health issue and is closely related to chronic kidney disorder (CKD). In people with CKD, strict monitoring of blood pressure is an important part of therapy. Objective: The aim of this research was to validate the iHealth Track blood pressure monitoring device for patients with CKD according to the European Society of Hypertension International Protocol 2010 (ESH-IP2). Methods: In total, 33 patients who received hemodialysis in Plasencia participated in the study. There were 9 successive measurements made, which conformed to the ESH-IP2. We calculated the differences between the standard reference device (Omron M3 Intellisense) and the test device (iHealth Track) for blood pressure and heart rate values. For 99 total comparisons of paired measurements, we classified differences into various categories (≤5 mmHg, ≤10 mmHg, and ≤15 mmHg for blood pressure; ≤3, ≤5, and ≤8 beats per minute for heart rate). Results: In 90 of 99 systolic blood pressure and 89 of 99 diastolic blood pressure comparisons between the devices, measurement differences were within 5 mmHg. In 81 of 99 heart rate comparisons between the devices, measurement differences were within 3 beats per minute. The mean differences between the test and reference standard measurements were 3.27 (SD 2.99) mmHg for systolic blood pressure, 3.59 (SD 4.55) mmHg for diastolic blood pressure, and 2.18 (SD 2.75) beats per minute for heart rate. We also observed that for both systolic and diastolic blood pressure, 31 of 33 participants had at least two of three comparisons between the devices with measurement differences less than 5 mmHg. For heart rate, 28 of 33 patients had at least two of three comparisons between the devices with measurement differences less than 3 beats per minute. Conclusions: To our knowledge, this is the first study to show that iHealth Track meets the requirements of the ESH-IP2 in patients with CKD. Therefore, the iHealth Track is suitable for use in renal patients.
  • Item
    QardioArm(R) Blood pressure monitoring in a population with Type 2 diabetes: Validation Study.
    (Journal of Medical Internet Research, 2020) Mazoteras Pardo, Victoria; Becerro De Bengoa Vallejo, Ricardo; Losa Iglesias, Marta Elena; Martínez Jiménez, Eva María; Calvo Lobo, César; Romero Morales, Carlos; López López, Daniel; Palomo Lopez, Patricia
    Background: Home blood pressure monitoring has many benefits, even more so, in populations prone to high blood pressure, such as persons with diabetes. Objective: The purpose of this research was to validate the QardioArm mobile device in a sample of individuals with noninsulin-dependent type 2 diabetes in accordance with the guidelines of the second International Protocol of the European Society of Hypertension. Methods: The sample consisted of 33 patients with type 2 diabetes. To evaluate the validity of QardioArm by comparing its data with that obtained with a digital sphygmomanometer (Omron M3 Intellisense), two nurses collected diastolic blood pressure, systolic blood pressure, and heart rate with both devices. Results: The analysis indicated that the test device QardioArm met all the validation requirements using a sample population with type 2 diabetes. Conclusions: This paper reports the first validation of QardioArm in a population of individuals with noninsulin-dependent type 2 diabetes. QardioArm for home monitoring of blood pressure and heart rate met the requirements of the second International Protocol of the European Society of Hypertension.
  • Item
    Pressure and Traction technique improve Postural Control more than tactile stimulation in foot plantar fascia. A randomized single-blind trial.
    (Archives of Physical Medicine and Rehabilitation, 2020) Losa Iglesias ,Marta Elena; Díaz Velázquez, José Ignacio; Palomo López, Patricia; López López, Daniel; Martínez Jiménez, Eva María; Becerro De Bengoa Vallejo, Ricardo; Rodríguez Sanz, David; Calvo Lobo, César
    Objective To check the acute effects of manual pressure and traction technique on balance and plantar footprint variables. Design A single-blind clinical study with 2 groups. Setting Private practice. Participants Healthy participants (N=40; 28 female and 12 male) were recruited to carry out a single-blind study. Interventions Experimental group performed a bilateral plantar fascia manual pressure and traction technique. Control group performed a tactile stimulation. The position of the participant, the therapist, and the time of application of the techniques (5min) were the same for both interventions. Main Outcome Measures We measured stabilometry variables and static footprint. The footprint variables were divided in rear, middle, and front foot areas. Results Significant differences were found in stabilometry variables. There was an improvement in experimental group at X displacement with eyes open (P=.014) and surface eyes closed (P=.046) variables. Conclusions After technique the experimental group improved the stabilometry variables, specifically surface with eyes closed and X displacement with eyes open. The static footprint variables have not shown differences after the technique compared with the control group. Section snippets Participant characteristics Forty healthy participants (28 female and 12 male) were recruited to carry out a single-blind clinical study. The Ethics Committee of the University approved the study, number authorization 2111201814518, and all participants had to sign an informed consent. The protocol of this study was registered at ClinicalTrials.gov (No.: NCT03997955). The standards and guidelines recommended in the Council of Europe Convention on Human Rights and Biomedicine UNESCO Universal, the Declaration on the Human Results Subjects were 39.42±10.41 years old, had height of 167.65±8.39 cm, and weight of 67.72±9.11 kg. Table 1 shows all demographic data. A total of 24 of the 38 variables did not follow a normal distribution. Parametric tests were used in these variables. No results were obtained with statistically significant differences between the experimental group and the control group at baseline before therapy (table 2). There were statistically significant differences between the groups after therapy in the Discussion This study uses a pressure platform to measure the immediate effects of the manual pressure and traction technique of the plantar fascia on the static footprint and stabilometry compared with an active control group. After technique, the experimental group improved the stabilometry variables correctly, surface with eyes closed and X displacement with eyes open with significant differences. The static footprint variables have not shown differences after the technique compared with the control Conclusions Manual pressure and traction technique of the plantar fascia improved the stabilometry variables, surface with eyes closed and X displacement with eyes open. The static footprint variables have not shown differences after the technique compared with the control of tactile stimulation.
  • Item
    The reliability, Validity and Sensitivity Measures of Edmonton Frail Scale (EFS) in older adults patiens with foot disorders
    (Aging, 2020) Navarro Flores, Emanuel; Becerro De Bengoa Vallejo, Ricardo; Losa Iglesias. Marta Elena; Palomo López, Patricia; Calvo Lobo, César; López López, Daniel; Martínez Jiménez, Eva María; Romero Morales, Carlos
    The Edmonton Frail Scale (EFS) is an index employed to measure alterations related to frailty. The main objective in this research was to develop the EFS short-form (EFS-SF) and to evaluate its validity, reliability, and sensitivity to predict frailty disability outcomes in elderly patients with foot disabilities. Results: Exploratory factor analysis (EFA) of the EFS-SF revealed the presence of three components, as in the original EFA. There were significant differences (p < 0.05) in the study population for several of the EFS and 5-item FRAIL scale indicators. The highest correlation (Pearson R = 0.871; p < 0.001) was found for the first component of the EFS-SF. Finally, the Cronbach alpha was 0.864 which indicated a high level of internal consistency. Conclusion: The EFS-SF is a reliable and valid instrument to measure frailty in patients with and without foot disabilities. Method: A cross sectional descriptive study was carried out. The study population was aged over 60 years (n = 66) and comprised 29 men and 37 women. Frailty disorders were registered by using the EFS, 5-item FRAIL scale, and the Geriatricians’ Clinical Impression of Frailty (GCIF) scale. EFA was employed to locate potential constituents of the EFS, with scores ranging from 0.596 to 0.946 for each of the sub scales: (1) cognitive and general health status; (2) medication and nutrition status; and (3) functional and physiological status, thus revealing that the EFS-SF comprised three components, a reduction compared to the nine in the original EFS.
  • Item
    Electromyography comparison of the effects of various footwear in the activity patterns of the peroneus longus and brevis muscles
    (Journal of the mechanical behavior of biomedical materials, 2018) Roca Dols, Andrea; Losa Iglesias, Marta Elena; Sánchez Gómez, Rubén; López López, Daniel; Becerro De Bengoa Vallejo, Ricardo; Calvo Lobo, César
    Background Peroneus longus and brevis (PLB) disorders are commonly in people with lateral ligamentous instability, ankle pain, lateral hindfoot pain and structures of the proximal compartment of the lower legs and their muscle activity is believed to be influenced by different footwear types. The proposal of this research is to evaluate the effects of five types of footwear with respect to the barefoot condition and analyze the activity patterns of PLB muscles in healthy subjects during the gait cycle. Methods Thirty healthy subjects were recruited in a laboratory in this cross-sectional research design. While walking, electromyography (EMG) activity was measured from PLB via surface electrodes in six experimental conditions: 1) barefoot, 2) minimalist, 3) pronated control, 4) air chamber, 5) ethyl-vinyl-acetate (EVA) and 6) boost. These data were obtained and compared. Results The peroneus brevis showed significant reductions in the peak amplitude of the five footwear types (minimalist, pronation control, air chamber, EVA and boost) with respect to the barefoot condition in the propulsion phase of the gait cycle during walking (P = 0.034; P < 0.001; P < 0.001; P < 0.001; P = 0.006) and running (P = 0.004; P < 0.001; P = 0.001; P < 0.001; P = 0.001), respectively. Furthermore, peroneus longus showed significant reductions in the peak amplitude of these five footwear types with respect to the barefoot condition in the propulsion phase of the gait cycle during running (P = 0.005; P = 0.038; P = 0.019; P = 0.025; P = 0.021). Conclusion The EMG activity patterns of the PLB muscles may depend on the use of different types of sport shoes such as minimalist, pronation control, air chamber, EVA and boost footwear with respect the barefoot condition in different phases of the gait cycle during walking and running.
  • Item
    Dry needling of the flexor digitorum brevis muscle reduces postural control in standing: A pre-post stabilometric study.
    (Journal of Anatomy, 2023) Martínez Jiménez, Eva María; Losa Iglesias, Marta Elena; Mazoteras Pardo Victoria; López López, Daniel; Pereiro Buceta, Héctor; Calvo Lobo, César; Rodríguez Sanz, David; Becerro De Bengoa Vallejo, Ricardo; Navarro Flores Emmanuel
    There are studies that show the better balance after dry needling in lumbar pain. However, the postural control effects after foot dry needling are unknown. Our objective was to check if dry needling reduces postural control. Eighteen subjects with flexor digitorum brevis (FDB) muscle Myofascial trigger point were evaluated pre- and post-deep dry needling. We measured stabilometric variables in a pre-post study. We have found significant differences in three stabilometric variables: surface with eyes closed (29.36–53.21 mm2) (p = 0.000), medium speed of the laterolateral displacement with eyes closed (1.42–1.64 mm/s) (p = 0.004), and medium speed of the anteroposterior displacement with eyes closed (1.30–1.53 mm/s) (p = 0.025). Dry needling therapy application in FDB muscle reduces standing postural control with eyes closed.
  • Item
    Electromyography activity of triceps surae and tibialis anterior muscles related to various sports shoes
    (Journal of the mechanical behavior of biomedical materials., 2018) Roca Dols, Andrea; Losa Iglesias, Marta Elena; Sánchez Gómez, Rubén; Becerro De Bengoa Vallejo, Ricardo; López López, Daniel; Palomo López, Patricia; Rodríguez Sanz, David; Calvo Lobo, César
    Triceps surae (TS) and tibialis anterior (TA) activation patterns have not yet been studied under different types of sport shoes. We hypothesized that sports shoes may reduce the activity patterns of these muscles in relation to barefoot condition. Thus, our main aim was to evaluate the activity patterns of TS and TA muscles in healthy people during all gait phases using five types of sport shoes with respect to barefoot condition. A total sample of thirty healthy participants, mean age 36.20 ± 8.50, was recruited in a podiatry laboratory following an observational research design. During walking and running, electromyography signals were recorded from TS and TA muscles using surface electrodes in the following experimental situations: 1.) barefoot, 2.) minimalist, 3.) pronated control, 4.) air chamber, 5.) ethyl-vinyl-acetate and 6.) boost. The TS and TA showed significant reductions (P < 0.05) in the peak amplitude of different sport shoes types with respect to the barefoot condition in different phases of the gait cycle during walking and running. Nevertheless, the boost sport shoe produced statistically significant increases in the peak amplitude of the gastrocnemius medialis muscle in comparison with the barefoot condition in the midstance phase of the gait cycle during running (P = 0.047). In addition, the pronation control and air chamber sport shoes produced statistically significant increases in the peak amplitude of the TA muscle with respect to the barefoot condition in the contact phase of the gait cycle (P = 0.021; P = 0.013), respectively, during running. Despite TS and TA muscles activity patterns seem to be reduced using different sport shoes types with respect to the barefoot condition in different phases of the gait cycle during walking and running, some sport shoes may increase this muscular activity in specific phases of the gait cycle during running.