Person:
Fernández Pérez, Cristina

Loading...
Profile Picture
First Name
Cristina
Last Name
Fernández Pérez
Affiliation
Universidad Complutense de Madrid
Faculty / Institute
Enfermería, Fisioterapia y Podología
Department
Enfermería
Area
Enfermería
Identifiers
UCM identifierORCIDScopus Author IDWeb of Science ResearcherIDDialnet ID

Search Results

Now showing 1 - 5 of 5
  • Item
    Effects of Implantable Collamer Lens V4c Placement on Iridocorneal Angle Measurements by Fourier-Domain Optical Coherence Tomography
    (American Journal of Ophthalmology, 2016) Fernández-Vigo, José Ignacio; Macarro Merino, Ana; Fernández-Vigo Escribano, Cristina; Fernández-Vigo, José Ángel; Martínez De La Casa Fernández-Borrella, José María; Fernández Pérez, Cristina; García Feijoo, Julián
    Purpose To assess by Fourier-domain optical coherence tomography (FDOCT) changes produced in iridocorneal angle measurements in patients undergoing Visian Implantable Collamer Lens (ICL) V4c (STAAR Surgical AG) placement. Design Prospective interventional case series. Methods In 50 eyes of 25 myopic subjects consecutively scheduled for ICL implant, FDOCT (RTVue; Optovue Inc) iridocorneal angle measurements were made before and 1 and 3 months after surgery. Trabecular-iris angle (TIA) and angle opening distance 500 μm anterior to the scleral spur (AOD500) were compared among the quadrants nasal, temporal, and inferior, and correlations with ocular variables including lens vault were examined. Results Preoperative TIA was 48.7 ± 8.7, 48.2 ± 8.7, and 48.7 ± 9.3 degrees for the nasal, temporal, and inferior quadrants, with no differences (P= 1.000). Following ICL implant, corresponding values fell to 31.2 ± 11.5, 30.0 ± 10.7, and 29.7 ± 8.1 degrees at 1 month postsurgery, indicating angle narrowing of 34%-42%, and to 30.6 ± 12.3, 30.1 ± 11.9, and 29.8 ± 12.3 degrees, respectively, at 3 months postsurgery. Angle measurements failed to vary between 1 month and 3 months postsurgery (P= .481). In 8 eyes, iridotrabecular contact attributable to surgery was observed. One month after surgery, vault measurements correlated with TIA (R = -.309;P= .048). Six variables were identified as predictors of TIA at 1 month postsurgery (R2= .907). Conclusions Although considerable angle narrowing was detected 1 month after ICL V4c implant, this narrowing remained stable at 3 months postsurgery. Factors predictive of TIA could serve to identify suitable candidates for ICL placement.
  • Item
    Agreement and clinical comparison between a new swept-source optical coherence tomography-based optical biometer and an optical low-coherence reflectometry biometer
    (Eye, 2017) Arriola Villalobos, Pedro; Almendral Gómez, Jaime; Garzón Jiménez, Nuria; Ruiz Medrano, Jorge; Fernández Pérez, Cristina; Martínez De La Casa Fernández-Borrella, José María; Díaz Valle, David
    Purpose To compare measurements taken using a swept-source optical coherence tomography-based optical biometer (IOLmaster 700) and an optical low-coherence reflectometry biometer (Lenstar 900), and to determine the clinical impacts of differences in their measurements on intraocular lens (IOL) power predictions. Methods Eighty eyes of 80 patients scheduled to undergo cataract surgery were examined with both biometers. The measurements made using each device were axial length (AL), central corneal thickness (CCT), aqueous depth (AQD), lens thickness (LT), mean keratometry (MK), white-to-white distance (WTW), and pupil diameter (PD). Holladay 2 and SRK/T formulas were used to calculate IOL power. Differences in measurement between the two biometers were determined using the paired t-test. Agreement was assessed through intraclass correlation coefficients (ICC) and Bland-Altman plots. Results Mean patient age was 76.3±6.8 years (range 59-89). Using the Lenstar, AL and PD could not be measured in 12.5 and 5.25% of eyes, respectively, while IOLMaster 700 took all measurements in all eyes. The variables CCT, AQD, LT, and MK varied significantly between the two biometers. According to ICCs, correlation between measurements made with both devices was excellent except for WTW and PD. Using the SRK/T formula, IOL power prediction based on the data from the two devices were statistically different, but differences were not clinically significant. Conclusions No clinically relevant differences were detected between the biometers in terms of their measurements and IOL power predictions. Using the IOLMaster 700, it was easier to obtain biometric measurements in eyes with less transparent ocular media or longer AL.
  • Item
    Fourier domain optical coherence tomography to assess the iridocorneal angle and correlation study in a large Caucasian population
    (BMC Ophthalmology, 2016) Fernández Vigo, José Ignacio; García Feijoo, Julián; Martínez De La Casa Fernández-Borrella, José María; García Bella, Javier; Arriola Villalobos, Pedro; Fernández Pérez, Cristina; Fernández Vigo, José Ángel
    Background: Recently, novel anatomic parameters that can be measured by optical coherence tomography (OCT), have been identified as a more objective and accurate method of defining the iridocorneal angle. The aim of the present study is to measure the iridocorneal angle by Fourier domain (FD) OCT and to identify correlations between angle measurements and subject factors in a large healthy Caucasian population. Methods: A cross sectional study was performed in 989 left eyes of 989 healthy subjects. The iridocorneal angle measurements: trabecular-iris angle (TIA), angle opening distance (AOD500) and trabecular-iris space area (TISA500) 500 μm from the scleral spur, were made using the FD-OCT RTVue®. Iris thickness was also measured. Correlations were examined between angle measurements and demographic and ocular factors. The main determinants of angle width were identified by multivariate linear regression. Results: TIA could be measured in 94 % of the eyes, and AOD500 and TISA500 in 92 %. The means recorded were TIA 35.8 ± 12.2 degrees (range 1.5 to 76.1), AOD500 542.6 ± 285.4 μm (range 15 to 1755), and TISA500 0.195 ± 0.104 mm2 (range 0.02 to 0.62). The correlation between the temporal and nasal quadrant was R = 0.902 for TIA. The reproducibility of measurements was excellent (intraclass correlation coefficient >0.947). Mean angle width measurements were smaller in women (p = 0.02). Correlation was detected between angle means and anterior chamber volume (ACV; R = 0.848), anterior chamber depth (ACD; R = 0.818), spherical error (R = -0.619) and age (R = -0.487), while no correlation was observed with Intraocular pressure (R = -0.052). ACV emerged as the main determinant of TIA (R2 = 0.705; p < 0.001). Conclusions: In this Caucasian population, strong correlation was detected between FD-OCT anterior angle measurements and ACV, ACD, spherical refractive error and sex, emerging the ACV as the main determinant of TIA.
  • Item
    Glaukos iStent inject® Trabecular Micro-Bypass Implantation Associated with Cataract Surgery in Patients with Coexisting Cataract and Open-Angle Glaucoma or Ocular Hypertension: A Long-Term Study
    (Journal of Ophthalmology, 2016) Arriola Villalobos, Pedro; Martínez De La Casa Fernández-Borrella, José María; Díaz Valle, David; Morales Fernández, Laura; Fernández Pérez, Cristina; García Feijoo, Julián
    Purpose. To evaluate the long-term efficacy and safety of the iStent inject device (Glaukos Corporation, Laguna Hills, CA) combined with phacoemulsification in patients with coexistent cataract and open-angle glaucoma or ocular hypertension (OHT). Methods. A prospective, uncontrolled, nonrandomized, interventional case series study was conducted in patients with both mild or moderate open-angle glaucoma or OHT and cataract. Patients underwent cataract surgery along with the implant of two iStent inject devices. Outcome measures were intraocular pressure (IOP), topical hypotensive medications required, and best-corrected visual acuity (BCVA). Results. 20 patients were enrolled. Mean follow-up was months. Mean baseline IOP was  mmHg with medication and  mmHg after washout. Mean end-follow-up IOP was  mmHg, representing an IOP decrease of 36.92%,  mmHg (), from baseline washout IOP. The mean number of medications was significantly reduced from to (). 45% of patients were medication-free by the end of follow-up. Mean BCVA improved significantly from to (). No complications of surgery were observed. Conclusion. The iStent inject device combined with cataract surgery served to significantly reduce both IOP and medication use in the long term in patients with coexistent open-angle glaucoma or ocular hypertension (OHT) and cataract.
  • Item
    Ocular Surface Disease in Patients under Topical Treatment for Glaucoma
    (European Journal of Ophthalmology, 2018) Pérez Bartolomé, Francisco; Martínez De La Casa Fernández-Borrella, José María; Arriola Villalobos, Pedro; Fernández Pérez, Cristina; Polo Llorens, Vicente; García Feijoo, Julián
    Purpose: To examine the relationship between ocular surface disease (OSD) and topical antiglaucoma therapy. Methods: A total of 211 eyes of 211 patients with open-angle glaucoma or ocular hypertension on topical medication were recruited over 10 months. Controls were 51 eyes of 51 healthy age- and sex-matched volunteers. In each patient, we recorded the intraocular pressure-lowering eyedrops used, the number of medications used, and daily and cumulative preservative concentrations (PC). Main outcome measures were fluorescein corneal staining score (Oxford scale), lower tear meniscus height (LTMH) (spectral-domain optical coherence tomography), noninvasive tear film breakup time (NI-TBUT) (Oculus Keratograph 5M), and OSD symptom questionnaire index (OSDI). Results: Compared to controls, significantly higher OSDI (median [interquartile range] 10.24 [4.54-18.94] vs 2.5 [0-12.5]; p<0.001) and corneal staining (≥1: 64.93% vs 32.61%; p<0.001) scores were recorded in the medication group. The NI-TBUT and LTMH failed to vary between the groups (p>0.05). A higher daily PC was associated with a lower LTMH (R −0.142; p = 0.043). In the medication group, multivariate analysis identified correlations between benzalkonium chloride (BAK) (odds ratio [OR] 1.56) and BAK plus polyquaternium-containing drops (OR 5.09) or higher OSDI (OR 1.06) and abnormal corneal staining test results and between older age (mean ratio [MR] 1.05), longer treatment duration (MR 1.02), or corneal staining presence (MR 1.22) and a higher OSDI score. Conclusions: Ocular surface disease was more prevalent in the medication group. The main factors impacting OSD were drops with preservatives, longer treatment duration, and older age.