Effects of Implantable Collamer Lens V4c Placement on Iridocorneal Angle Measurements by Fourier-Domain Optical Coherence Tomography

Loading...
Thumbnail Image
Full text at PDC
Publication date

2016

Authors
Fernández-Vigo, José Ignacio
Macarro Merino, Ana
Fernández-Vigo Escribano, Cristina
Fernández-Vigo, José Ángel
Advisors (or tutors)
Editors
Journal Title
Journal ISSN
Volume Title
Publisher
Elsevier Masson
Citations
Google Scholar
Citation
Fernández-Vigo, J. I., Macarro Merino, A., Fernández-Vigo Escribano, C. et al. «Effects of Implantable Collamer Lens V4c Placement on Iridocorneal Angle Measurements by Fourier-Domain Optical Coherence Tomography». American Journal of Ophthalmology, vol. 162, febrero de 2016, pp. 43-52.e1. DOI.org (Crossref), https://doi.org/10.1016/j.ajo.2015.11.010.
Abstract
Purpose To assess by Fourier-domain optical coherence tomography (FDOCT) changes produced in iridocorneal angle measurements in patients undergoing Visian Implantable Collamer Lens (ICL) V4c (STAAR Surgical AG) placement. Design Prospective interventional case series. Methods In 50 eyes of 25 myopic subjects consecutively scheduled for ICL implant, FDOCT (RTVue; Optovue Inc) iridocorneal angle measurements were made before and 1 and 3 months after surgery. Trabecular-iris angle (TIA) and angle opening distance 500 μm anterior to the scleral spur (AOD500) were compared among the quadrants nasal, temporal, and inferior, and correlations with ocular variables including lens vault were examined. Results Preoperative TIA was 48.7 ± 8.7, 48.2 ± 8.7, and 48.7 ± 9.3 degrees for the nasal, temporal, and inferior quadrants, with no differences (P= 1.000). Following ICL implant, corresponding values fell to 31.2 ± 11.5, 30.0 ± 10.7, and 29.7 ± 8.1 degrees at 1 month postsurgery, indicating angle narrowing of 34%-42%, and to 30.6 ± 12.3, 30.1 ± 11.9, and 29.8 ± 12.3 degrees, respectively, at 3 months postsurgery. Angle measurements failed to vary between 1 month and 3 months postsurgery (P= .481). In 8 eyes, iridotrabecular contact attributable to surgery was observed. One month after surgery, vault measurements correlated with TIA (R = -.309;P= .048). Six variables were identified as predictors of TIA at 1 month postsurgery (R2= .907). Conclusions Although considerable angle narrowing was detected 1 month after ICL V4c implant, this narrowing remained stable at 3 months postsurgery. Factors predictive of TIA could serve to identify suitable candidates for ICL placement.
Research Projects
Organizational Units
Journal Issue
Description
Keywords
Collections