Person:
Lorente Velázquez, Amalia

Loading...
Profile Picture
First Name
Amalia
Last Name
Lorente Velázquez
Affiliation
Universidad Complutense de Madrid
Faculty / Institute
Óptica y Optometría
Department
Optometría y Visión
Area
Optica
Identifiers
UCM identifierORCIDScopus Author IDDialnet IDGoogle Scholar ID

Search Results

Now showing 1 - 5 of 5
  • Item
    Effects of Blink Rate on Tear Film Optical Quality Dynamics with Different Soft Contact Lenses
    (Journal of Ophthalmology, 2019) García Montero, María; Rico del Viejo, Laura; Martínez Alberquilla, Irene; Hernández Verdejo, José Luis; Lorente Velázquez, Amalia; Madrid Costa, David
    Objective. The aim of this study was to investigate tear film optical quality dynamics for four types of silicone hydrogel contact lenses (SHCLs) for daily wear over a 15-day period and for different blink rate (BR) patterns. Methods. A prospective randomized, double-blind, cross-over pilot study including four SHCLs (A: lotrafilcon B (Air Optix plus HydraGlyde, Alcon Laboratories); B: samfilcon A (Ultra, Bausch & Lomb); C: comfilcon A (Biofinity, CooperVision); and D: filcom V3 (Blu:gen, Mark’Ennovy)). Serial measurements of Objective Scatter Index (OSI) using the HD Analyzer (Visiometrics S.L., Terrassa, Spain) were taken at different blinking patterns: blinking every 2.5 seconds (high BRs) and every 9 seconds (low BRs). They were performed during the first visit before CL insertion (baseline), after 20 minutes of CL wear (Day 1), and during the last visit after 8 hours of CL wear on day 15 of use (Day 15). Results. Normal young healthy subjects were recruited and fitted with the four lenses. For low BRs, the mean OSI value increased over time for all CLs and the slope of the curve also increased for all CLs, except for CL D. However, for high BRs, the mean OSI value increased only for CLs B and C and the slope of the curve did not change over time for any of them. Conclusions. These results suggest that the tear film optical quality dynamics after wearing SCHLs for 15 days seems to undergo a slight deterioration only for lowest BR.
  • Item
    Changes in Optical Quality Induced by Tilt and Decentration of a Trifocal IOL and a Novel Extended Depth of Focus IOL in Eyes with Corneal Myopic Ablations
    (Journal of Refractive Surgery, 2021) Ruiz Alcocer, Javier; Martínez Alberquilla, Irene; Rementería Capelo, Laureano A; Gracia Pacheco, Pablo de; Lorente Velázquez, Amalia
    PURPOSE: To assess the effect of decentration and tilt combined with prior myopic ablations on the optical performance of a trifocal intraocular lens (IOL) and a novel IOL with an extended depth of focus (EDOF) design. METHODS: The XACT Mono-EDOF ME4 (Santen Pharmaceutical Co Ltd) and the trifocal FineVision (PhysIOL) IOLs were analyzed with and without simulated previous myopic ablations. The optical quality of the IOLs was evaluated with the PMTF optical bench (LAMBDA-X). The through-focus modulation transfer function (MTF) curves were recorded. Measurements were done for three situations: centered, 0.4 mm decentered, and 4 degrees tilted. RESULTS: The trifocal IOL showed three peaks of vision and the EDOF IOL showed a far distance peak with intermediate addition. When decentration or tilt were induced, the trifocal IOL showed negligible changes but the EDOF IOL showed a -0.50 diopters (D) shift of the overall curve. With simulated myopic ablation, the trifocal IOL showed a -0.50 D shift of the curve. When tilt or decentration were also induced, the better optical results were found at -1.00 D. With myopic ablations, the EDOF IOL showed a -0.50 D shift of the optical quality and when decentration or tilt were then induced, negative shifts over -1.00 D were found. CONCLUSIONS: The trifocal IOL was less affected by misalignments. When myopic ablations were induced, both lenses decreased their optical quality and the effects of misalignments were higher. In patients who have undergone corneal myopic ablation procedures, proper alignment of the implanted IOL and obtaining effective emmetropia becomes even more critical.
  • Item
    Repeatability of Noninvasive Keratograph 5M Measurements Associated With Contact Lens Wear
    (Eye & Contact lens, 2019) García Montero, María; Rico del Viejo, Laura; Lorente Velázquez, Amalia; Martínez Alberquilla, Irene; Hernández Verdejo, José Luis; Madrid Costa, David
    Objetive: To assess the intrarater repeatability of the measurements of tear meniscus height (TMH), noninvasive keratograph tear break-up time (NIKBUTs), and ocular redness measurements obtained with the Keratograph 5M (K5M) in a sample of soft silicone hydrogel contact lens (CL) wearers over 15 days. Methods: Prospective study over two consecutive weeks. Three measurements of TMH, NIKBUTs (NIKBUT first and NIKBUT average), and ocular redness were obtained in different sessions; the first day (baseline, at 8 hr of wear, and after lens removal) and the last day of wear-15th day (at 8 hr of wear and after lens removal). The repeatability of measurements were assessed by two intraclass correlation coefficient (ICC) forms; single measurement [ICC (2,1)] and multiple measurements (k=3) [ICC (2, k)]. Results: Sixty-four eyes were analyzed. The repeatability of baseline TMH [ICC (2,1) greater than 0.90; coefficient of repeatability (CR)=0.06 mm] and after and during CL wear [ICC (2,k) greater than 0.90; CR≤0.07 mm] were excellent. The repeatability of baseline NIKBUT average [ICC (2,k)=0.89 (0.82-0.93); CR=6.07 sec] was maintained after CL removal but was poorer during CL wear. The repeatability of baseline NIKBUT first [ICC (2,k) =0.80 (0.69-0.87); CR=8.74 sec] was maintained after CL removal and during CL wear at moderate-good level. Conclusions: Intrarater repeatability of TMH, NIKBUTs, and ocular redness performed by K5M after CL wear remains stable when three measurements are performed. However, intrarater repeatability during CL wear decreased only for NIKBUT average and was not affected by time of use (15 days).
  • Item
    Forward-scattered and backward-scattered light in moderate keratoconus
    (Ophthalmic and Physiological Optics, 2023) Villanueva Gómez-Chacón, Celia; Viviano, Francesco; García Montero, María; Lorente Velázquez, Amalia; Martínez Alberquilla, Irene; Garzón Jiménez, Nuria
    Introduction: To evaluate the backscattered light, objective scatter index (OSI) and retinal straylight in patients with moderate keratoconus and healthy control subjects. Methods: A prospective observational study was developed with 33 patients in the moderate-keratoconus group (KC) and 34 in the non-keratoconus group (NKC). Corneal densitometry was obtained using Scheimpflug corneal tomography and measurements were expressed in grayscale units (GSU) over four zones within a 12.00 mm diameter around the corneal apex. A straylight meter was used to determine the amount of intraocular straylight under scotopic conditions, and the straylight parameter (LOG(s)) and test duration were recorded. The Optical Quality Analysis System based on the double-pass technique determined the OSI value. Results: Significant differences were observed between the KC and NKC groups for corneal densitometry (except in the 6–10 mm zone), OSI and retinal straylight. A moderate and significant correlation was found between OSI and retinal straylight LOG(s) (r = 0.52, p = 0.002). Weaker and non-significant correlations were found between corneal densitometry and the other parameters analysed (i.e., OSI, retinal straylight LOG(s) and retinal straylight times). Conclusions: Backscattered light, retinal straylight and the OSI show clear differences between healthy eyes and those with moderate KC. The changes present in the stages of KC evaluated in the current study (stages II and III according to the Amsler–Krumeich classification) might alter the scattering of the light entering the eye.
  • Item
    Project number: 202
    Aplicación de un programa informatizado para emitir informes clínicos en la asignatura de Clínica Optométrica I
    (2019) García Montero, María; Hernández Verdejo, José Luis; Madrid Costa, David; Gómez Sanz, Fernando Javier; Lorente Velázquez, Amalia; Rico Del Viejo, Laura; Martínez Alberquilla, Irene
    El objetivo es optimizar el uso de un programa informático de registro y almacenamiento de datos clínicos y la creación de una nueva herramienta para generar informes clínicos. Los informes clínicos forman parte de la evaluación del alumno.