Intra- and inter-session reliability and repeatability of an infrared thermography device designed for materials to measure skin temperature of the triceps surae muscle tissue of athletes

dc.contributor.authorCalvo Lobo, César
dc.contributor.authorSan Antolín, Marta
dc.contributor.authorGarcía García, Daniel
dc.contributor.authorBecerro De Bengoa Vallejo, Ricardo
dc.contributor.authorLosa Iglesias, Marta Elena
dc.contributor.authorCosín Matamoros, Julia
dc.contributor.authorCasado Hernández, Israel
dc.contributor.authorMartínez Jiménez, Eva María
dc.contributor.authorMazoteras Pardo, Victoria
dc.contributor.authorRodríguez Sanz, David
dc.date.accessioned2025-10-07T12:19:04Z
dc.date.available2025-10-07T12:19:04Z
dc.date.issued2023-03-09
dc.descriptionCésar Calvo-Lobo, David Rodríguez-Sanz and Ricardo Becerro-de-Bengoa-Vallejo declared that this work has been supported by a Contract 83 between the Complutense University and PCE Ibérica S.L. entitle “Fiabilidad sobre el dispositivo de termografía Manual Infrared camera PCE-TC 30 en humanos” (Reference number: 6-2020).
dc.description.abstractBackground Infrared thermography devices have been commonly applied to measure superficial temperature in structural composites and walls. These tools were cheaper than other thermographic devices used to measure superficial human muscle tissue temperature. In addition, infrared thermography has been previously used to assess skin temperature related to muscle tissue conditions in the triceps surae of athletes. Nevertheless, the reliability and repeatability of an infrared thermography device designed for materials, such as the Manual Infrared Camera PCE-TC 30, have yet to be determined to measure skin temperature of the triceps surae muscle tissue of athletes. Objective The purpose was to determine the procedure’s intra- and inter-session reliability and repeatability to determine skin temperature within the Manual Infrared Camera PCE-TC 30 thermography device in the triceps surae muscle tissue of athletes, which was initially designed to measure the superficial temperature of materials. Methods A total of 34 triceps surae muscles were bilaterally assessed from 17 healthy athletes using the Manual Infrared Camera PCE-TC 30 thermography device to determine intra- (at the same day separated by 1 h) and inter-session (at alternate days separated by 48 h) reliability and repeatability of the skin temperature of the soleus, medial and lateral gastrocnemius muscles. The triceps surae complex weas measured by a region of interest of 1 cm2 through five infrared thermography images for each muscle. Statistical analyses comprised intraclass correlation coefficient (ICC), standard error of measurement (SEM), minimum detectable change (MCD), systematic error of measurement, correlation (r), and Bland-Altman plots completed with linear regression models (R2). Results Intra- and inter-session measurements of the proposed infrared thermography procedure showed excellent reliability (ICC(1,2) = 0.968–0.977), measurement errors (SEM = 0.186–0.232 °C; MDC = 0.515–0.643 °C), correlations (r = 0.885–0.953), and did not present significant systematic error of measurements (P > 0.05). Adequate agreement between each pair of measurement moments was presented by the Bland-Altman plots according to the limits of agreement and non-significant linear regression models (R2 = 0.000–0.019; P > 0.05). Conclusions The proposed procedure to determine skin temperature within the Manual Infrared Camera PCE-TC 30 thermography device presented excellent intra- and inter-session reliability and repeatability in athletes’ triceps surae muscle tissue. Future studies should consider the SEM and MDC of this procedure to measure the skin temperature of soleus, medial, and lateral gastrocnemius muscles to promote triceps surae muscle prevention and recovery in athletes.
dc.description.departmentDepto. de Enfermería
dc.description.facultyFac. de Enfermería, Fisioterapia y Podología
dc.description.refereedTRUE
dc.description.sponsorshipUniversidad Complutense de Madrid
dc.description.sponsorshipPCE Ibérica S.L.
dc.description.statuspub
dc.identifier.citationCalvo-Lobo, Cesar, et al. «Intra- and inter-session reliability and repeatability of an infrared thermography device designed for materials to measure skin temperature of the triceps surae muscle tissue of athletes». PeerJ, vol. 11, 2023, https://doi.org/10.7717/PEERJ.15011.
dc.identifier.doi10.7717/peerj.15011
dc.identifier.issn2167-8359
dc.identifier.officialurlhttps://doi.org/10.7717/peerj.15011
dc.identifier.relatedurlhttps://peerj.com/articles/15011/
dc.identifier.urihttps://hdl.handle.net/20.500.14352/124587
dc.journal.titlePeerJ
dc.language.isoeng
dc.page.final20
dc.page.initial1
dc.publisherPeerJ Inc.
dc.rightsAttribution 4.0 Internationalen
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subject.cdu616.718.7/.9
dc.subject.keywordLower extremity
dc.subject.keywordReproducibility of results
dc.subject.keywordData management
dc.subject.keywordSports
dc.subject.keywordThermosensing
dc.subject.ucmPodología
dc.subject.unesco3299 Otras Especialidades Médicas
dc.titleIntra- and inter-session reliability and repeatability of an infrared thermography device designed for materials to measure skin temperature of the triceps surae muscle tissue of athletes
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number11
dspace.entity.typePublication
relation.isAuthorOfPublication9420a0f4-5654-4ad9-a920-e9521d454023
relation.isAuthorOfPublicationbbd621a9-7baf-481a-83c7-124287192d07
relation.isAuthorOfPublication67d39ea6-525c-4626-b6c4-4ea6b2c8e7b7
relation.isAuthorOfPublication7a04a197-3d62-4c6d-90f4-d49924b46327
relation.isAuthorOfPublication3d3e5c8a-15a9-4991-97ee-ea886940b1a5
relation.isAuthorOfPublication.latestForDiscovery9420a0f4-5654-4ad9-a920-e9521d454023

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Intra_and_inter_session.pdf
Size:
15.51 MB
Format:
Adobe Portable Document Format

Collections