Influence of the ambient color lighting on the accuracy of complete arch implant scans recorded by using two intraoral scanners
dc.contributor.author | Ochoa López, Gastón | |
dc.contributor.author | Revilla León, Marta | |
dc.contributor.author | Gómez Polo, Miguel Ángel | |
dc.date.accessioned | 2024-10-23T11:56:03Z | |
dc.date.available | 2024-10-23T11:56:03Z | |
dc.date.issued | 2024-04-30 | |
dc.description.abstract | Objectives: To measure the influence of scanning pattern on the accuracy, time, and number of photograms of complete-arch intraoral implant scans. Methods: A maxillary edentulous patient with 7 implants was selected. The reference implant cast was obtained using conventional methods (7Series Scanner). Four groups were created based on the scanning pattern used to acquire the complete-arch implant scans by using an intraoral scanner (IOS) (Trios4): manufacturer’s recom- mended (Occlusal-Buccal-Lingual (OBL)), zig-zag (Zig-zag), circumferential (Circumf), and novel pattern that included locking an initial occlusal scan (O-Lock group) (n = 15). Scanning time and number of photograms were recorded. The linear and angular measurements were used to assess scanning accuracy. One-way ANOVA and Tukey tests were used to analyze trueness, scanning time, and number of photograms. The Levene test was selected to assess precision (α=0.05). Results: Statistically significant differences in trueness were detected among OBL, Zig-zag, Circumf, and O-Lock regarding linear discrepancy (P < 0.01), angular discrepancy (P < 0.01), scanning time (P < 0.01), and number of photograms (P < 0.01). The O-Lock (63 ± 20 μm) showed the best linear trueness with statistically significant differences (P < 0.01) with Circumferential (86 ± 16 μm) and OBL (87 ± 19 μm) groups. The O-Lock (93.5 ± 13.4 s, 1080 ± 104 photograms) and Circumf groups (102.9 ± 15.1 s, 1112 ± 179 photograms) obtained lower scanning times (P < 0.01) and number of photograms (P < 0.01) than OBL (130.3 ± 19.4 s, 1293 ± 161 pho- tograms) and Zig-zag (125.7 ± 22.1 s, 1316 ± 160 photograms) groups. Conclusions: The scanning patterns tested influenced scanning accuracy, time, and number of photograms of the complete-arch scans obtained by using the IOS tested. The zig-zag and O-Lock scanning patterns are recom- mended to obtain complete-arch implant scans when using the selected IOS. | en |
dc.description.department | Depto. de Odontología Conservadora y Prótesis | |
dc.description.faculty | Fac. de Odontología | |
dc.description.fundingtype | APC financiada por la UCM | |
dc.description.refereed | TRUE | |
dc.description.status | inpress | |
dc.identifier.citation | Ochoa-López G, Revilla-León M, Gómez-Polo M. Influence of the ambient color lighting on the accuracy of complete arch implant scans recorded by using two intraoral scanners. J Prosthet Dent. 2024 Apr 22:S0022-3913(24)00224-5. doi: 10.1016/j.prosdent.2024.03.030. Epub ahead of print. PMID: 38653690. | |
dc.identifier.doi | 10.1016/j.prosdent.2024.03.030 | |
dc.identifier.issn | 0022-3913 | |
dc.identifier.officialurl | https//doi.org/10.1016/j.prosdent.2024.03.030 | |
dc.identifier.pmid | 38653690 | |
dc.identifier.relatedurl | https://www.thejpd.org/ | |
dc.identifier.uri | https://hdl.handle.net/20.500.14352/109317 | |
dc.journal.title | Journal of Prosthetic Dentistry | |
dc.language.iso | eng | |
dc.publisher | Elsevier | |
dc.rights.accessRights | open access | |
dc.subject.cdu | 616.314-089.843 | |
dc.subject.keyword | Color lighting | |
dc.subject.keyword | Complete arch | |
dc.subject.keyword | Dental implants | |
dc.subject.keyword | Intraoral scanners | |
dc.subject.ucm | Odontología (Odontología) | |
dc.subject.ucm | Implantes dentales | |
dc.subject.unesco | 3213.13 Ortodoncia-Estomatología | |
dc.title | Influence of the ambient color lighting on the accuracy of complete arch implant scans recorded by using two intraoral scanners | en |
dc.type | journal article | |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | 9700c70b-34f2-4d6a-8e12-92587c9186fb | |
relation.isAuthorOfPublication.latestForDiscovery | 9700c70b-34f2-4d6a-8e12-92587c9186fb |
Download
Original bundle
1 - 1 of 1
Loading...
- Name:
- Influence of the ambient color lighting.pdf
- Size:
- 2.62 MB
- Format:
- Adobe Portable Document Format